Cargando…

Extraction-Free, Direct Determination of Caffeine in Microliter Volumes of Beverages by Thermal Desorption-Gas Chromatography Mass Spectrometry

An extraction-free method requiring microliter (μL) volumes has been developed for the determination of caffeine in beverages. Using a pyrolysis-gas chromatography mass spectrometry system, the conditions required for the direct thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) dete...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Xianglu, Brown, Melanie, Bowdler, Paul, Honeychurch, Kevin C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7152966/
https://www.ncbi.nlm.nih.gov/pubmed/32308685
http://dx.doi.org/10.1155/2020/5405184
_version_ 1783521588429193216
author Peng, Xianglu
Brown, Melanie
Bowdler, Paul
Honeychurch, Kevin C.
author_facet Peng, Xianglu
Brown, Melanie
Bowdler, Paul
Honeychurch, Kevin C.
author_sort Peng, Xianglu
collection PubMed
description An extraction-free method requiring microliter (μL) volumes has been developed for the determination of caffeine in beverages. Using a pyrolysis-gas chromatography mass spectrometry system, the conditions required for the direct thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) determination of caffeine were optimised. A 5 μL aliquot was introduced to the thermal desorption unit, dried, and thermally desorbed to the GC/MS. The response was linear over the range 10 to 500 μg/mL (R(2) = 0.996). The theoretical limit of detection (3 σ) was 0.456 μg/mL. No interferences were recorded from endogenous beverage components or from commonly occurring drugs, such as nicotine, ibuprofen, and paracetamol. Replicate caffeine determinations on fortified latte style white coffee and Pepsi Max® gave mean recoveries of 93.4% (%CV = 4.1%) and 95.0% (%CV = 0.98%), respectively. Good agreement was also obtained with the stated values of caffeine for an energy drink and for Coca-Cola®. These data suggest that the method holds promise for the determination of caffeine in such samples.
format Online
Article
Text
id pubmed-7152966
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-71529662020-04-17 Extraction-Free, Direct Determination of Caffeine in Microliter Volumes of Beverages by Thermal Desorption-Gas Chromatography Mass Spectrometry Peng, Xianglu Brown, Melanie Bowdler, Paul Honeychurch, Kevin C. Int J Anal Chem Research Article An extraction-free method requiring microliter (μL) volumes has been developed for the determination of caffeine in beverages. Using a pyrolysis-gas chromatography mass spectrometry system, the conditions required for the direct thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) determination of caffeine were optimised. A 5 μL aliquot was introduced to the thermal desorption unit, dried, and thermally desorbed to the GC/MS. The response was linear over the range 10 to 500 μg/mL (R(2) = 0.996). The theoretical limit of detection (3 σ) was 0.456 μg/mL. No interferences were recorded from endogenous beverage components or from commonly occurring drugs, such as nicotine, ibuprofen, and paracetamol. Replicate caffeine determinations on fortified latte style white coffee and Pepsi Max® gave mean recoveries of 93.4% (%CV = 4.1%) and 95.0% (%CV = 0.98%), respectively. Good agreement was also obtained with the stated values of caffeine for an energy drink and for Coca-Cola®. These data suggest that the method holds promise for the determination of caffeine in such samples. Hindawi 2020-04-01 /pmc/articles/PMC7152966/ /pubmed/32308685 http://dx.doi.org/10.1155/2020/5405184 Text en Copyright © 2020 Xianglu Peng et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Peng, Xianglu
Brown, Melanie
Bowdler, Paul
Honeychurch, Kevin C.
Extraction-Free, Direct Determination of Caffeine in Microliter Volumes of Beverages by Thermal Desorption-Gas Chromatography Mass Spectrometry
title Extraction-Free, Direct Determination of Caffeine in Microliter Volumes of Beverages by Thermal Desorption-Gas Chromatography Mass Spectrometry
title_full Extraction-Free, Direct Determination of Caffeine in Microliter Volumes of Beverages by Thermal Desorption-Gas Chromatography Mass Spectrometry
title_fullStr Extraction-Free, Direct Determination of Caffeine in Microliter Volumes of Beverages by Thermal Desorption-Gas Chromatography Mass Spectrometry
title_full_unstemmed Extraction-Free, Direct Determination of Caffeine in Microliter Volumes of Beverages by Thermal Desorption-Gas Chromatography Mass Spectrometry
title_short Extraction-Free, Direct Determination of Caffeine in Microliter Volumes of Beverages by Thermal Desorption-Gas Chromatography Mass Spectrometry
title_sort extraction-free, direct determination of caffeine in microliter volumes of beverages by thermal desorption-gas chromatography mass spectrometry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7152966/
https://www.ncbi.nlm.nih.gov/pubmed/32308685
http://dx.doi.org/10.1155/2020/5405184
work_keys_str_mv AT pengxianglu extractionfreedirectdeterminationofcaffeineinmicrolitervolumesofbeveragesbythermaldesorptiongaschromatographymassspectrometry
AT brownmelanie extractionfreedirectdeterminationofcaffeineinmicrolitervolumesofbeveragesbythermaldesorptiongaschromatographymassspectrometry
AT bowdlerpaul extractionfreedirectdeterminationofcaffeineinmicrolitervolumesofbeveragesbythermaldesorptiongaschromatographymassspectrometry
AT honeychurchkevinc extractionfreedirectdeterminationofcaffeineinmicrolitervolumesofbeveragesbythermaldesorptiongaschromatographymassspectrometry