Cargando…
New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle
INTRODUCTION: The Mechanical Muscle Activity with Real-time Kinematics project aims to develop a device incorporating wearable sensors for arm rehabilitation following stroke. These will record kinematic activity using inertial measurement units and mechanical muscle activity. The gold standard for...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7153181/ https://www.ncbi.nlm.nih.gov/pubmed/32313684 http://dx.doi.org/10.1177/2055668320916116 |
_version_ | 1783521605526224896 |
---|---|
author | Meagher, Claire Franco, Enrico Turk, Ruth Wilson, Samuel Steadman, Nathan McNicholas, Lauren Vaidyanathan, Ravi Burridge, Jane Stokes, Maria |
author_facet | Meagher, Claire Franco, Enrico Turk, Ruth Wilson, Samuel Steadman, Nathan McNicholas, Lauren Vaidyanathan, Ravi Burridge, Jane Stokes, Maria |
author_sort | Meagher, Claire |
collection | PubMed |
description | INTRODUCTION: The Mechanical Muscle Activity with Real-time Kinematics project aims to develop a device incorporating wearable sensors for arm rehabilitation following stroke. These will record kinematic activity using inertial measurement units and mechanical muscle activity. The gold standard for measuring muscle activity is electromyography; however, mechanomyography offers an appropriate alterative for our home-based rehabilitation device. We have patent filed a new laboratory-tested device that combines an inertial measurement unit with mechanomyography. We report on the validity and reliability of the mechanomyography against electromyography sensors. METHODS: In 18 healthy adults (27–82 years), mechanomyography and electromyography recordings were taken from the forearm flexor and extensor muscles during voluntary contractions. Isometric contractions were performed at different percentages of maximal force to examine the validity of mechanomyography. Root-mean-square of mechanomyography and electromyography was measured during 1 s epocs of isometric flexion and extension. Dynamic contractions were recorded during a tracking task on two days, one week apart, to examine reliability of muscle onset timing. RESULTS: Reliability of mechanomyography onset was high (intraclass correlation coefficient = 0.78) and was comparable with electromyography (intraclass correlation coefficient = 0.79). The correlation between force and mechanomyography was high (R(2) = 0.94). CONCLUSION: The mechanomyography device records valid and reliable signals of mechanical muscle activity on different days. |
format | Online Article Text |
id | pubmed-7153181 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-71531812020-04-20 New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle Meagher, Claire Franco, Enrico Turk, Ruth Wilson, Samuel Steadman, Nathan McNicholas, Lauren Vaidyanathan, Ravi Burridge, Jane Stokes, Maria J Rehabil Assist Technol Eng Original Article INTRODUCTION: The Mechanical Muscle Activity with Real-time Kinematics project aims to develop a device incorporating wearable sensors for arm rehabilitation following stroke. These will record kinematic activity using inertial measurement units and mechanical muscle activity. The gold standard for measuring muscle activity is electromyography; however, mechanomyography offers an appropriate alterative for our home-based rehabilitation device. We have patent filed a new laboratory-tested device that combines an inertial measurement unit with mechanomyography. We report on the validity and reliability of the mechanomyography against electromyography sensors. METHODS: In 18 healthy adults (27–82 years), mechanomyography and electromyography recordings were taken from the forearm flexor and extensor muscles during voluntary contractions. Isometric contractions were performed at different percentages of maximal force to examine the validity of mechanomyography. Root-mean-square of mechanomyography and electromyography was measured during 1 s epocs of isometric flexion and extension. Dynamic contractions were recorded during a tracking task on two days, one week apart, to examine reliability of muscle onset timing. RESULTS: Reliability of mechanomyography onset was high (intraclass correlation coefficient = 0.78) and was comparable with electromyography (intraclass correlation coefficient = 0.79). The correlation between force and mechanomyography was high (R(2) = 0.94). CONCLUSION: The mechanomyography device records valid and reliable signals of mechanical muscle activity on different days. SAGE Publications 2020-04-09 /pmc/articles/PMC7153181/ /pubmed/32313684 http://dx.doi.org/10.1177/2055668320916116 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/ Creative Commons CC BY: This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Meagher, Claire Franco, Enrico Turk, Ruth Wilson, Samuel Steadman, Nathan McNicholas, Lauren Vaidyanathan, Ravi Burridge, Jane Stokes, Maria New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle |
title | New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle |
title_full | New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle |
title_fullStr | New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle |
title_full_unstemmed | New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle |
title_short | New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle |
title_sort | new advances in mechanomyography sensor technology and signal processing: validity and intrarater reliability of recordings from muscle |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7153181/ https://www.ncbi.nlm.nih.gov/pubmed/32313684 http://dx.doi.org/10.1177/2055668320916116 |
work_keys_str_mv | AT meagherclaire newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle AT francoenrico newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle AT turkruth newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle AT wilsonsamuel newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle AT steadmannathan newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle AT mcnicholaslauren newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle AT vaidyanathanravi newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle AT burridgejane newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle AT stokesmaria newadvancesinmechanomyographysensortechnologyandsignalprocessingvalidityandintraraterreliabilityofrecordingsfrommuscle |