Cargando…

Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging

BACKGROUND: To assess the radius of anterior lens surface curvature (RAL) measurements with anterior segment optical coherence tomography (AS-OCT) in comparison with Scheimpflug imaging. METHODS: This prospective, cross-sectional study was carried out at Zhongshan Ophthalmic Center, Guangzhou, China...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zhenzhen, Ruan, Xiaoting, Wang, Wei, Liu, Juzi, Meng, Yijing, Gu, Xiaoxun, Fu, Jun, Luo, Lixia, Liu, Yizhi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7154444/
https://www.ncbi.nlm.nih.gov/pubmed/32309324
http://dx.doi.org/10.21037/atm.2020.01.100
_version_ 1783521819020492800
author Liu, Zhenzhen
Ruan, Xiaoting
Wang, Wei
Liu, Juzi
Meng, Yijing
Gu, Xiaoxun
Fu, Jun
Luo, Lixia
Liu, Yizhi
author_facet Liu, Zhenzhen
Ruan, Xiaoting
Wang, Wei
Liu, Juzi
Meng, Yijing
Gu, Xiaoxun
Fu, Jun
Luo, Lixia
Liu, Yizhi
author_sort Liu, Zhenzhen
collection PubMed
description BACKGROUND: To assess the radius of anterior lens surface curvature (RAL) measurements with anterior segment optical coherence tomography (AS-OCT) in comparison with Scheimpflug imaging. METHODS: This prospective, cross-sectional study was carried out at Zhongshan Ophthalmic Center, Guangzhou, China. We enrolled 59 eyes, including 30 eyes from 30 cataractous volunteers (59 to 87 years) and 29 eyes from 29 young participants (19 to 49 years). After mydriasis, the RAL was measured automatically by the built-in software in the AS-OCT (CASIA 2). The Scheimpflug images were measured with the build-in caliper tool of the Scheimpflug camera (Pentacam), and RAL were further calculated with the principle of best-fitted circle. Intraobserver and interobserver reproducibility of RAL measurement using Scheimpflug camera were evaluated with limit of agreement (LoA) and intraclass correlation coefficient (ICC). Consistency between RAL measurement of Scheimpflug camera and AS-OCT were assessed with LoA, correlation analysis and linear regression. RESULTS: For all subjects, intraobserver (LoA: −0.25 to 0.23 mm, ICC: 0.996) and interobserver reproducibility (LoA: −0.85 to 0.92 mm, ICC: 0.947) of RAL were good using Scheimpflug imaging. Both AS-OCT and Scheimpflug imaging found that the age-related cataract participants had smaller RAL (P=0.010, P=0.001 respectively). LoA of RAL measurement between AS-OCT and Scheimpflug imaging was −3.83 to −0.79 mm, and the Pearson correlation efficient was 0.909 (P<0.001). The RAL values measured by AS-OCT were significantly greater than that by Scheimpflug camera with a mean difference of 2.31 mm for all participants (P<0.001). The RAL measurement could be converted using the equation: Y(CASIA 2) =1.155 × X(Pentacam) + 1.060. CONCLUSIONS: Both Scheimpflug camera system with internal caliper tool and the AS-OCT are fast and non-contact tools that could measure RAL successfully. The two measurement results are highly correlated and interchangeable through linear regression equation.
format Online
Article
Text
id pubmed-7154444
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-71544442020-04-17 Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging Liu, Zhenzhen Ruan, Xiaoting Wang, Wei Liu, Juzi Meng, Yijing Gu, Xiaoxun Fu, Jun Luo, Lixia Liu, Yizhi Ann Transl Med Original Article BACKGROUND: To assess the radius of anterior lens surface curvature (RAL) measurements with anterior segment optical coherence tomography (AS-OCT) in comparison with Scheimpflug imaging. METHODS: This prospective, cross-sectional study was carried out at Zhongshan Ophthalmic Center, Guangzhou, China. We enrolled 59 eyes, including 30 eyes from 30 cataractous volunteers (59 to 87 years) and 29 eyes from 29 young participants (19 to 49 years). After mydriasis, the RAL was measured automatically by the built-in software in the AS-OCT (CASIA 2). The Scheimpflug images were measured with the build-in caliper tool of the Scheimpflug camera (Pentacam), and RAL were further calculated with the principle of best-fitted circle. Intraobserver and interobserver reproducibility of RAL measurement using Scheimpflug camera were evaluated with limit of agreement (LoA) and intraclass correlation coefficient (ICC). Consistency between RAL measurement of Scheimpflug camera and AS-OCT were assessed with LoA, correlation analysis and linear regression. RESULTS: For all subjects, intraobserver (LoA: −0.25 to 0.23 mm, ICC: 0.996) and interobserver reproducibility (LoA: −0.85 to 0.92 mm, ICC: 0.947) of RAL were good using Scheimpflug imaging. Both AS-OCT and Scheimpflug imaging found that the age-related cataract participants had smaller RAL (P=0.010, P=0.001 respectively). LoA of RAL measurement between AS-OCT and Scheimpflug imaging was −3.83 to −0.79 mm, and the Pearson correlation efficient was 0.909 (P<0.001). The RAL values measured by AS-OCT were significantly greater than that by Scheimpflug camera with a mean difference of 2.31 mm for all participants (P<0.001). The RAL measurement could be converted using the equation: Y(CASIA 2) =1.155 × X(Pentacam) + 1.060. CONCLUSIONS: Both Scheimpflug camera system with internal caliper tool and the AS-OCT are fast and non-contact tools that could measure RAL successfully. The two measurement results are highly correlated and interchangeable through linear regression equation. AME Publishing Company 2020-03 /pmc/articles/PMC7154444/ /pubmed/32309324 http://dx.doi.org/10.21037/atm.2020.01.100 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Liu, Zhenzhen
Ruan, Xiaoting
Wang, Wei
Liu, Juzi
Meng, Yijing
Gu, Xiaoxun
Fu, Jun
Luo, Lixia
Liu, Yizhi
Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging
title Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging
title_full Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging
title_fullStr Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging
title_full_unstemmed Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging
title_short Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging
title_sort comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and scheimpflug imaging
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7154444/
https://www.ncbi.nlm.nih.gov/pubmed/32309324
http://dx.doi.org/10.21037/atm.2020.01.100
work_keys_str_mv AT liuzhenzhen comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging
AT ruanxiaoting comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging
AT wangwei comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging
AT liujuzi comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging
AT mengyijing comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging
AT guxiaoxun comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging
AT fujun comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging
AT luolixia comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging
AT liuyizhi comparisonofradiusofanteriorlenssurfacecurvaturemeasurementsinvivousingtheanteriorsegmentopticalcoherencetomographyandscheimpflugimaging