Cargando…

Artificial urinary sphincter: current status and future directions

Urge urinary incontinence (UUI) is one of the most troublesome complications of surgery of the prostate whether for malignancy or benign conditions. For many decades, there have been attempts to reduce the morbidity of this outcome with variable results. Since its development in the 1970s, the artif...

Descripción completa

Detalles Bibliográficos
Autor principal: Carson, Culley C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7155799/
https://www.ncbi.nlm.nih.gov/pubmed/32129191
http://dx.doi.org/10.4103/aja.aja_5_20
_version_ 1783522110448074752
author Carson, Culley C
author_facet Carson, Culley C
author_sort Carson, Culley C
collection PubMed
description Urge urinary incontinence (UUI) is one of the most troublesome complications of surgery of the prostate whether for malignancy or benign conditions. For many decades, there have been attempts to reduce the morbidity of this outcome with variable results. Since its development in the 1970s, the artificial urinary sphincter (AUS) has been the “gold standard” for treatment of the most severe cases of UUI. Other attempts including injectable bulking agents, previous sphincter designs, and slings have been developed, but largely abandoned because of poor long-term efficacy and significant complications. The AUS has had several sentinel redesigns since its first introduction to reduce erosion and infection and increase efficacy. None of these changes in the basic AUS design have occurred in the past three decades, and the AUS remains the same despite newer technology and materials that could improve its function and safety. Recently, newer compressive devices and slings to reposition the bladder neck for men with mild-to-moderate UUI have been developed with success in select patients. Similarly, the AUS has had applied antibiotic coating to all portions except the pressure-regulating balloon (PRB) to reduce infection risk. The basic AUS design, however, has not changed. With newer electronic technology, the concept of the electronic AUS or eAUS has been proposed and several possible iterations of this eAUS have been reported. While the eAUS is as yet not available, its development continues and a prototype device may be available soon. Possible design options are discussed in this review.
format Online
Article
Text
id pubmed-7155799
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-71557992020-04-21 Artificial urinary sphincter: current status and future directions Carson, Culley C Asian J Androl Invited Review Urge urinary incontinence (UUI) is one of the most troublesome complications of surgery of the prostate whether for malignancy or benign conditions. For many decades, there have been attempts to reduce the morbidity of this outcome with variable results. Since its development in the 1970s, the artificial urinary sphincter (AUS) has been the “gold standard” for treatment of the most severe cases of UUI. Other attempts including injectable bulking agents, previous sphincter designs, and slings have been developed, but largely abandoned because of poor long-term efficacy and significant complications. The AUS has had several sentinel redesigns since its first introduction to reduce erosion and infection and increase efficacy. None of these changes in the basic AUS design have occurred in the past three decades, and the AUS remains the same despite newer technology and materials that could improve its function and safety. Recently, newer compressive devices and slings to reposition the bladder neck for men with mild-to-moderate UUI have been developed with success in select patients. Similarly, the AUS has had applied antibiotic coating to all portions except the pressure-regulating balloon (PRB) to reduce infection risk. The basic AUS design, however, has not changed. With newer electronic technology, the concept of the electronic AUS or eAUS has been proposed and several possible iterations of this eAUS have been reported. While the eAUS is as yet not available, its development continues and a prototype device may be available soon. Possible design options are discussed in this review. Wolters Kluwer - Medknow 2020-02-25 /pmc/articles/PMC7155799/ /pubmed/32129191 http://dx.doi.org/10.4103/aja.aja_5_20 Text en Copyright: ©The Author(s)(2020) http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Invited Review
Carson, Culley C
Artificial urinary sphincter: current status and future directions
title Artificial urinary sphincter: current status and future directions
title_full Artificial urinary sphincter: current status and future directions
title_fullStr Artificial urinary sphincter: current status and future directions
title_full_unstemmed Artificial urinary sphincter: current status and future directions
title_short Artificial urinary sphincter: current status and future directions
title_sort artificial urinary sphincter: current status and future directions
topic Invited Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7155799/
https://www.ncbi.nlm.nih.gov/pubmed/32129191
http://dx.doi.org/10.4103/aja.aja_5_20
work_keys_str_mv AT carsonculleyc artificialurinarysphinctercurrentstatusandfuturedirections