Cargando…

Influence of Patient-Specific Head Modeling on EEG Source Imaging

Electromagnetic source imaging (ESI) techniques have become one of the most common alternatives for understanding cognitive processes in the human brain and for guiding possible therapies for neurological diseases. However, ESI accuracy strongly depends on the forward model capabilities to accuratel...

Descripción completa

Detalles Bibliográficos
Autores principales: Céspedes-Villar, Yohan, Martinez-Vargas, Juan David, Castellanos-Dominguez, G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7157795/
https://www.ncbi.nlm.nih.gov/pubmed/32328152
http://dx.doi.org/10.1155/2020/5076865
_version_ 1783522424147410944
author Céspedes-Villar, Yohan
Martinez-Vargas, Juan David
Castellanos-Dominguez, G.
author_facet Céspedes-Villar, Yohan
Martinez-Vargas, Juan David
Castellanos-Dominguez, G.
author_sort Céspedes-Villar, Yohan
collection PubMed
description Electromagnetic source imaging (ESI) techniques have become one of the most common alternatives for understanding cognitive processes in the human brain and for guiding possible therapies for neurological diseases. However, ESI accuracy strongly depends on the forward model capabilities to accurately describe the subject's head anatomy from the available structural data. Attempting to improve the ESI performance, we enhance the brain structure model within the individual-defined forward problem formulation, combining the head geometry complexity of the modeled tissue compartments and the prior knowledge of the brain tissue morphology. We validate the proposed methodology using 25 subjects, from which a set of magnetic-resonance imaging scans is acquired, extracting the anatomical priors and an electroencephalography signal set needed for validating the ESI scenarios. Obtained results confirm that incorporating patient-specific head models enhances the performed accuracy and improves the localization of focal and deep sources.
format Online
Article
Text
id pubmed-7157795
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-71577952020-04-23 Influence of Patient-Specific Head Modeling on EEG Source Imaging Céspedes-Villar, Yohan Martinez-Vargas, Juan David Castellanos-Dominguez, G. Comput Math Methods Med Research Article Electromagnetic source imaging (ESI) techniques have become one of the most common alternatives for understanding cognitive processes in the human brain and for guiding possible therapies for neurological diseases. However, ESI accuracy strongly depends on the forward model capabilities to accurately describe the subject's head anatomy from the available structural data. Attempting to improve the ESI performance, we enhance the brain structure model within the individual-defined forward problem formulation, combining the head geometry complexity of the modeled tissue compartments and the prior knowledge of the brain tissue morphology. We validate the proposed methodology using 25 subjects, from which a set of magnetic-resonance imaging scans is acquired, extracting the anatomical priors and an electroencephalography signal set needed for validating the ESI scenarios. Obtained results confirm that incorporating patient-specific head models enhances the performed accuracy and improves the localization of focal and deep sources. Hindawi 2020-04-03 /pmc/articles/PMC7157795/ /pubmed/32328152 http://dx.doi.org/10.1155/2020/5076865 Text en Copyright © 2020 Yohan Céspedes-Villar et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Céspedes-Villar, Yohan
Martinez-Vargas, Juan David
Castellanos-Dominguez, G.
Influence of Patient-Specific Head Modeling on EEG Source Imaging
title Influence of Patient-Specific Head Modeling on EEG Source Imaging
title_full Influence of Patient-Specific Head Modeling on EEG Source Imaging
title_fullStr Influence of Patient-Specific Head Modeling on EEG Source Imaging
title_full_unstemmed Influence of Patient-Specific Head Modeling on EEG Source Imaging
title_short Influence of Patient-Specific Head Modeling on EEG Source Imaging
title_sort influence of patient-specific head modeling on eeg source imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7157795/
https://www.ncbi.nlm.nih.gov/pubmed/32328152
http://dx.doi.org/10.1155/2020/5076865
work_keys_str_mv AT cespedesvillaryohan influenceofpatientspecificheadmodelingoneegsourceimaging
AT martinezvargasjuandavid influenceofpatientspecificheadmodelingoneegsourceimaging
AT castellanosdominguezg influenceofpatientspecificheadmodelingoneegsourceimaging