Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model

BACKGROUND: Tendinopathy is a common musculoskeletal disorder and current treatment options show limited success. Genipin is an effective collagen crosslinker with low cytotoxicity and a promising therapeutic strategy for stabilizing an intratendinous lesion. PURPOSE: This study examined the mechani...

Descripción completa

Detalles Bibliográficos
Autores principales: Tondelli, Timo, Götschi, Tobias, Camenzind, Roland S., Snedeker, Jess G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7159246/
https://www.ncbi.nlm.nih.gov/pubmed/32294117
http://dx.doi.org/10.1371/journal.pone.0231619
_version_ 1783522625123778560
author Tondelli, Timo
Götschi, Tobias
Camenzind, Roland S.
Snedeker, Jess G.
author_facet Tondelli, Timo
Götschi, Tobias
Camenzind, Roland S.
Snedeker, Jess G.
author_sort Tondelli, Timo
collection PubMed
description BACKGROUND: Tendinopathy is a common musculoskeletal disorder and current treatment options show limited success. Genipin is an effective collagen crosslinker with low cytotoxicity and a promising therapeutic strategy for stabilizing an intratendinous lesion. PURPOSE: This study examined the mechanical effect and delivery of intratendinous genipin injection in healthy and degenerated tendons. STUDY DESIGN: Controlled laboratory study METHODS: Bovine superficial digital flexor tendons were randomized into four groups: Healthy control (N = 25), healthy genipin (N = 25), degenerated control (N = 45) and degenerated genipin (N = 45). Degeneration was induced by Collagenase D injection. After 24h, degenerated tendons were subsequently injected with either 0.2ml of 80mM genipin or buffer only. 24h post-treatment, samples were cyclically loaded for 500 cycles and then ramp loaded to failure. Fluorescence and absorption assays were performed to analyze genipin crosslink distribution and estimate tissue concentration after injection. RESULTS: Compared to controls, genipin treatment increased ultimate force by 19% in degenerated tendons (median control 530 N vs. 633 N; p = 0.0078). No significant differences in mechanical properties were observed in healthy tendons, while degenerated tendons showed a significant difference in ultimate stress (+23%, p = 0.049), stiffness (+27%, p = 0.037), work to failure (+42%, p = 0.009), and relative stress relaxation (-11%, p < 0.001) after genipin injection. Fluorescence and absorption were significantly higher in genipin treated tendons compared to control groups. A higher degree of crosslinking (+45%, p < 0.001) and a more localized distribution were observed in the treated healthy compared to degenerated tendons, with higher genipin tissue concentrations in healthy (7.9 mM) than in degenerated tissue (2.3 mM). CONCLUSION: Using an ex-vivo tendinopathy model, intratendinous genipin injections recovered mechanical strength to the level of healthy tendons. Measured by genipin tissue distribution, injection is an effective method for local delivery. CLINICAL RELEVANCE: This study provides a proof of concept for the use of intratendinous genipin injection in the treatment of tendinopathy. The results demonstrate that a degenerated tendon can be mechanically augmented by a clinically viable method of local genipin delivery. This warrants further in vivo studies towards the development of a clinically applicable treatment based on genipin.
format Online
Article
Text
id pubmed-7159246
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-71592462020-04-22 Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model Tondelli, Timo Götschi, Tobias Camenzind, Roland S. Snedeker, Jess G. PLoS One Research Article BACKGROUND: Tendinopathy is a common musculoskeletal disorder and current treatment options show limited success. Genipin is an effective collagen crosslinker with low cytotoxicity and a promising therapeutic strategy for stabilizing an intratendinous lesion. PURPOSE: This study examined the mechanical effect and delivery of intratendinous genipin injection in healthy and degenerated tendons. STUDY DESIGN: Controlled laboratory study METHODS: Bovine superficial digital flexor tendons were randomized into four groups: Healthy control (N = 25), healthy genipin (N = 25), degenerated control (N = 45) and degenerated genipin (N = 45). Degeneration was induced by Collagenase D injection. After 24h, degenerated tendons were subsequently injected with either 0.2ml of 80mM genipin or buffer only. 24h post-treatment, samples were cyclically loaded for 500 cycles and then ramp loaded to failure. Fluorescence and absorption assays were performed to analyze genipin crosslink distribution and estimate tissue concentration after injection. RESULTS: Compared to controls, genipin treatment increased ultimate force by 19% in degenerated tendons (median control 530 N vs. 633 N; p = 0.0078). No significant differences in mechanical properties were observed in healthy tendons, while degenerated tendons showed a significant difference in ultimate stress (+23%, p = 0.049), stiffness (+27%, p = 0.037), work to failure (+42%, p = 0.009), and relative stress relaxation (-11%, p < 0.001) after genipin injection. Fluorescence and absorption were significantly higher in genipin treated tendons compared to control groups. A higher degree of crosslinking (+45%, p < 0.001) and a more localized distribution were observed in the treated healthy compared to degenerated tendons, with higher genipin tissue concentrations in healthy (7.9 mM) than in degenerated tissue (2.3 mM). CONCLUSION: Using an ex-vivo tendinopathy model, intratendinous genipin injections recovered mechanical strength to the level of healthy tendons. Measured by genipin tissue distribution, injection is an effective method for local delivery. CLINICAL RELEVANCE: This study provides a proof of concept for the use of intratendinous genipin injection in the treatment of tendinopathy. The results demonstrate that a degenerated tendon can be mechanically augmented by a clinically viable method of local genipin delivery. This warrants further in vivo studies towards the development of a clinically applicable treatment based on genipin. Public Library of Science 2020-04-15 /pmc/articles/PMC7159246/ /pubmed/32294117 http://dx.doi.org/10.1371/journal.pone.0231619 Text en © 2020 Tondelli et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Tondelli, Timo
Götschi, Tobias
Camenzind, Roland S.
Snedeker, Jess G.
Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model
title Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model
title_full Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model
title_fullStr Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model
title_full_unstemmed Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model
title_short Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model
title_sort assessing the effects of intratendinous genipin injections: mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7159246/
https://www.ncbi.nlm.nih.gov/pubmed/32294117
http://dx.doi.org/10.1371/journal.pone.0231619
work_keys_str_mv AT tondellitimo assessingtheeffectsofintratendinousgenipininjectionsmechanicalaugmentationandspatialdistributioninanexvivodegenerativetendonmodel
AT gotschitobias assessingtheeffectsofintratendinousgenipininjectionsmechanicalaugmentationandspatialdistributioninanexvivodegenerativetendonmodel
AT camenzindrolands assessingtheeffectsofintratendinousgenipininjectionsmechanicalaugmentationandspatialdistributioninanexvivodegenerativetendonmodel
AT snedekerjessg assessingtheeffectsofintratendinousgenipininjectionsmechanicalaugmentationandspatialdistributioninanexvivodegenerativetendonmodel