Cargando…
Towards eco‐friendly secondary plant metabolite quantitation: Ultra high performance supercritical fluid chromatography applied to common vervain (Verbena officinalis L.)
This report presents the first ultra high performance supercritical fluid chromatography diode array detector based assay for simultaneous determination of iridoid glucosides, flavonoid glucuronides, and phenylpropanoid glycosides in Verbena officinalis (Verbenaceae) extracts. Separation of the key...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7160600/ https://www.ncbi.nlm.nih.gov/pubmed/31769179 http://dx.doi.org/10.1002/jssc.201900854 |
_version_ | 1783522790206341120 |
---|---|
author | Gibitz‐Eisath, Nora Eichberger, Miriam Gruber, Regina Seger, Christoph Sturm, Sonja Stuppner, Hermann |
author_facet | Gibitz‐Eisath, Nora Eichberger, Miriam Gruber, Regina Seger, Christoph Sturm, Sonja Stuppner, Hermann |
author_sort | Gibitz‐Eisath, Nora |
collection | PubMed |
description | This report presents the first ultra high performance supercritical fluid chromatography diode array detector based assay for simultaneous determination of iridoid glucosides, flavonoid glucuronides, and phenylpropanoid glycosides in Verbena officinalis (Verbenaceae) extracts. Separation of the key metabolites was achieved in less than 7 min on an Acquity UPC(2) Torus Diol column using a mobile phase gradient comprising subcritical carbon dioxide and methanol with 0.15% phosphoric acid. Method validation for seven selected marker compounds (hastatoside, verbenalin, apigenin‐7‐O‐glucuronide, luteolin‐7‐O‐glucuronide, apigenin‐7‐O‐diglucuronide, verbascoside, and luteolin‐7‐O‐diglucuronide) confirmed the assay to be sensitive, linear, precise, and accurate. Head‐to‐head comparison to an ultra high performance liquid chromatography comparator assay did prove the high orthogonality of the methods. Quantitative result equivalence was evaluated by Passing‐Bablok‐correlation and Bland‐Altman‐plot analysis. This cross‐validation revealed, that one of the investigated marker compound peaks was contaminated in the ultra high performance liquid chromatography assay by a structurally related congener. Taken together, it was proven that the ultra high performance supercritical fluid chromatography instrument setup with its orthogonal selectivity is a true alternative to conventional reversed phase liquid chromatography in quantitative secondary metabolite analysis. For regulatory purposes, assay cross‐validation with highly orthogonal methods seems a viable approach to avoid analyte overestimation due to coeluting, analytically indistinguishable contaminants. |
format | Online Article Text |
id | pubmed-7160600 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-71606002020-04-20 Towards eco‐friendly secondary plant metabolite quantitation: Ultra high performance supercritical fluid chromatography applied to common vervain (Verbena officinalis L.) Gibitz‐Eisath, Nora Eichberger, Miriam Gruber, Regina Seger, Christoph Sturm, Sonja Stuppner, Hermann J Sep Sci Other Techniques This report presents the first ultra high performance supercritical fluid chromatography diode array detector based assay for simultaneous determination of iridoid glucosides, flavonoid glucuronides, and phenylpropanoid glycosides in Verbena officinalis (Verbenaceae) extracts. Separation of the key metabolites was achieved in less than 7 min on an Acquity UPC(2) Torus Diol column using a mobile phase gradient comprising subcritical carbon dioxide and methanol with 0.15% phosphoric acid. Method validation for seven selected marker compounds (hastatoside, verbenalin, apigenin‐7‐O‐glucuronide, luteolin‐7‐O‐glucuronide, apigenin‐7‐O‐diglucuronide, verbascoside, and luteolin‐7‐O‐diglucuronide) confirmed the assay to be sensitive, linear, precise, and accurate. Head‐to‐head comparison to an ultra high performance liquid chromatography comparator assay did prove the high orthogonality of the methods. Quantitative result equivalence was evaluated by Passing‐Bablok‐correlation and Bland‐Altman‐plot analysis. This cross‐validation revealed, that one of the investigated marker compound peaks was contaminated in the ultra high performance liquid chromatography assay by a structurally related congener. Taken together, it was proven that the ultra high performance supercritical fluid chromatography instrument setup with its orthogonal selectivity is a true alternative to conventional reversed phase liquid chromatography in quantitative secondary metabolite analysis. For regulatory purposes, assay cross‐validation with highly orthogonal methods seems a viable approach to avoid analyte overestimation due to coeluting, analytically indistinguishable contaminants. John Wiley and Sons Inc. 2019-12-17 2020-02 /pmc/articles/PMC7160600/ /pubmed/31769179 http://dx.doi.org/10.1002/jssc.201900854 Text en © 2019 The Authors. Journal of Separation Science published by Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Other Techniques Gibitz‐Eisath, Nora Eichberger, Miriam Gruber, Regina Seger, Christoph Sturm, Sonja Stuppner, Hermann Towards eco‐friendly secondary plant metabolite quantitation: Ultra high performance supercritical fluid chromatography applied to common vervain (Verbena officinalis L.) |
title | Towards eco‐friendly secondary plant metabolite quantitation: Ultra high performance supercritical fluid chromatography applied to common vervain (Verbena officinalis L.) |
title_full | Towards eco‐friendly secondary plant metabolite quantitation: Ultra high performance supercritical fluid chromatography applied to common vervain (Verbena officinalis L.) |
title_fullStr | Towards eco‐friendly secondary plant metabolite quantitation: Ultra high performance supercritical fluid chromatography applied to common vervain (Verbena officinalis L.) |
title_full_unstemmed | Towards eco‐friendly secondary plant metabolite quantitation: Ultra high performance supercritical fluid chromatography applied to common vervain (Verbena officinalis L.) |
title_short | Towards eco‐friendly secondary plant metabolite quantitation: Ultra high performance supercritical fluid chromatography applied to common vervain (Verbena officinalis L.) |
title_sort | towards eco‐friendly secondary plant metabolite quantitation: ultra high performance supercritical fluid chromatography applied to common vervain (verbena officinalis l.) |
topic | Other Techniques |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7160600/ https://www.ncbi.nlm.nih.gov/pubmed/31769179 http://dx.doi.org/10.1002/jssc.201900854 |
work_keys_str_mv | AT gibitzeisathnora towardsecofriendlysecondaryplantmetabolitequantitationultrahighperformancesupercriticalfluidchromatographyappliedtocommonvervainverbenaofficinalisl AT eichbergermiriam towardsecofriendlysecondaryplantmetabolitequantitationultrahighperformancesupercriticalfluidchromatographyappliedtocommonvervainverbenaofficinalisl AT gruberregina towardsecofriendlysecondaryplantmetabolitequantitationultrahighperformancesupercriticalfluidchromatographyappliedtocommonvervainverbenaofficinalisl AT segerchristoph towardsecofriendlysecondaryplantmetabolitequantitationultrahighperformancesupercriticalfluidchromatographyappliedtocommonvervainverbenaofficinalisl AT sturmsonja towardsecofriendlysecondaryplantmetabolitequantitationultrahighperformancesupercriticalfluidchromatographyappliedtocommonvervainverbenaofficinalisl AT stuppnerhermann towardsecofriendlysecondaryplantmetabolitequantitationultrahighperformancesupercriticalfluidchromatographyappliedtocommonvervainverbenaofficinalisl |