Cargando…

BioMonitor 2 in-office setting insertion safety and feasibility evaluation with device functionality assessment: results from the prospective cohort BioInsight study

BACKGROUND: Insertable cardiac monitors are utilized for the diagnosis of arrhythmias and traditionally have been inserted within hospitals. Recent code updates allow for reimbursement of office-based insertions; however, there is limited information regarding the resources and processes required to...

Descripción completa

Detalles Bibliográficos
Autores principales: Awad, Khaled, Weiss, Raul, Yunus, Asim, Bittrick, Jon M., Nekkanti, Rajasekhar, Houmsse, Mahmoud, Okabe, Toshimasa, Adamson, Teagan, Miller, Crystal, Alawwa, Abdul K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7161128/
https://www.ncbi.nlm.nih.gov/pubmed/32293279
http://dx.doi.org/10.1186/s12872-020-01439-8
Descripción
Sumario:BACKGROUND: Insertable cardiac monitors are utilized for the diagnosis of arrhythmias and traditionally have been inserted within hospitals. Recent code updates allow for reimbursement of office-based insertions; however, there is limited information regarding the resources and processes required to support in-office insertions. We sought to determine the safety and feasibility of in-office insertion of the BioMonitor 2 and better understand in-office procedures, including patient selection, pre-insertion protocols, resource availability, and staff support. METHODS: Patients meeting an indication for a rhythm monitor were prospectively enrolled into this single-arm, non-randomized trial. All patients underwent insertion in an office setting. Two follow-up visits at days 7 and 90 were required. Information on adverse events, device performance, office site preparations, and resource utilization were collected. RESULTS: Eighty-two patients were enrolled at six sites. Insertion was successful in all 77 patients with an attempt. Oral anticoagulation was stopped in 20.8% of patients and continued through insertion in 23.4%, while prophylactic antibiotics were infrequently utilized (37.7% of study participants). On average, the procedure required a surgeon plus two support staff and 35 min in an office room to complete the 8.4 min insertion procedure. The mean R-wave amplitude was 0.77 mV at insertion and 0.67 mV at 90-days with low noise burden (2.7%). There were no procedure related complications. Two adverse events were reported (event rate 2.7% [95% CI 0.3, 9.5%]). CONCLUSIONS: In-office insertion of the BioMonitor 2 is safe and feasible. Devices performed well with high R-wave amplitudes and low noise burden. These results further support shifting cardiac monitor insertions to office-based locations. TRIAL REGISTRATION: clinicaltrials.gov, NCT02756338. Registered 29 April 2016.