Cargando…
Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy
BACKGROUND: The EVEREST II study reported superior polyp closure rates and visual outcomes using combination standard photodynamic therapy (PDT) with intravitreal ranibizumab in the treatment of polypoidal choroidal vasculopathy (PCV). The optimal PDT protocol remains controversial and it is postula...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7161176/ https://www.ncbi.nlm.nih.gov/pubmed/32293353 http://dx.doi.org/10.1186/s12886-020-01419-8 |
_version_ | 1783522906769195008 |
---|---|
author | Ngo, Wei Kiong Chee, Wai Kitt Tan, Colin S. Lim, Tock Han |
author_facet | Ngo, Wei Kiong Chee, Wai Kitt Tan, Colin S. Lim, Tock Han |
author_sort | Ngo, Wei Kiong |
collection | PubMed |
description | BACKGROUND: The EVEREST II study reported superior polyp closure rates and visual outcomes using combination standard photodynamic therapy (PDT) with intravitreal ranibizumab in the treatment of polypoidal choroidal vasculopathy (PCV). The optimal PDT protocol remains controversial and it is postulated that less intensive PDT strategies may reduce complications. We aimed to compare the efficacy of reduced and standard-fluence PDT. METHODS: Case-control review of 38 consecutive PDT-naïve macular PCV patients who underwent verteporfin PDT using one of two PDT regimens at a tertiary referral centre in an Asian population. Comparison of outcomes between standard-fluence PDT (light dose, 50 J/cm2; dose rate, 600 mW/cm2; wavelength, 689 nm PDT applied to the treatment eye for 83 s) and reduced-fluence PDT (light dose, 25 J/cm2; dose rate, 600 mW/cm2; wavelength, 689 nm PDT applied to the treatment eye for 42 s). Primary outcome measure was best corrected LogMAR visual acuity (VA). Secondary outcome measures included OCT measurements such as central retinal thickness (CRT), height of subfoveal sub-retinal fluid (SRF), central choroid thickness (CCT), mean number of PDT treatments needed, mean number of anti-VEGF injections needed, polyp closure and recurrence rates. RESULTS: Of these 38 eyes of 38 patients, an equal number of eyes (19 in each arm) were treated with standard-fluence and reduced-fluence PDT. Mean letter gain at 12 months for the standard-fluence group was 6.0 compared to 4.3 letters for the reduced-fluence group (p = 0.61). Similar results were observed at all time points. There was no statistically significant difference between the retinal and choroidal anatomical OCT outcomes, rates of polyp closure and recurrences between the two PDT regimens. CONCLUSIONS: Reduced-fluence PDT was comparable to standard-fluence PDT in the treatment of PCV in terms of visual gains, clinical and anatomical OCT outcomes. |
format | Online Article Text |
id | pubmed-7161176 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-71611762020-04-22 Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy Ngo, Wei Kiong Chee, Wai Kitt Tan, Colin S. Lim, Tock Han BMC Ophthalmol Research Article BACKGROUND: The EVEREST II study reported superior polyp closure rates and visual outcomes using combination standard photodynamic therapy (PDT) with intravitreal ranibizumab in the treatment of polypoidal choroidal vasculopathy (PCV). The optimal PDT protocol remains controversial and it is postulated that less intensive PDT strategies may reduce complications. We aimed to compare the efficacy of reduced and standard-fluence PDT. METHODS: Case-control review of 38 consecutive PDT-naïve macular PCV patients who underwent verteporfin PDT using one of two PDT regimens at a tertiary referral centre in an Asian population. Comparison of outcomes between standard-fluence PDT (light dose, 50 J/cm2; dose rate, 600 mW/cm2; wavelength, 689 nm PDT applied to the treatment eye for 83 s) and reduced-fluence PDT (light dose, 25 J/cm2; dose rate, 600 mW/cm2; wavelength, 689 nm PDT applied to the treatment eye for 42 s). Primary outcome measure was best corrected LogMAR visual acuity (VA). Secondary outcome measures included OCT measurements such as central retinal thickness (CRT), height of subfoveal sub-retinal fluid (SRF), central choroid thickness (CCT), mean number of PDT treatments needed, mean number of anti-VEGF injections needed, polyp closure and recurrence rates. RESULTS: Of these 38 eyes of 38 patients, an equal number of eyes (19 in each arm) were treated with standard-fluence and reduced-fluence PDT. Mean letter gain at 12 months for the standard-fluence group was 6.0 compared to 4.3 letters for the reduced-fluence group (p = 0.61). Similar results were observed at all time points. There was no statistically significant difference between the retinal and choroidal anatomical OCT outcomes, rates of polyp closure and recurrences between the two PDT regimens. CONCLUSIONS: Reduced-fluence PDT was comparable to standard-fluence PDT in the treatment of PCV in terms of visual gains, clinical and anatomical OCT outcomes. BioMed Central 2020-04-15 /pmc/articles/PMC7161176/ /pubmed/32293353 http://dx.doi.org/10.1186/s12886-020-01419-8 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Ngo, Wei Kiong Chee, Wai Kitt Tan, Colin S. Lim, Tock Han Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy |
title | Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy |
title_full | Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy |
title_fullStr | Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy |
title_full_unstemmed | Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy |
title_short | Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy |
title_sort | comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7161176/ https://www.ncbi.nlm.nih.gov/pubmed/32293353 http://dx.doi.org/10.1186/s12886-020-01419-8 |
work_keys_str_mv | AT ngoweikiong comparingefficacyofreducedfluenceandstandardfluencephotodynamictherapyinthetreatmentofpolypoidalchoroidalvasculopathy AT cheewaikitt comparingefficacyofreducedfluenceandstandardfluencephotodynamictherapyinthetreatmentofpolypoidalchoroidalvasculopathy AT tancolins comparingefficacyofreducedfluenceandstandardfluencephotodynamictherapyinthetreatmentofpolypoidalchoroidalvasculopathy AT limtockhan comparingefficacyofreducedfluenceandstandardfluencephotodynamictherapyinthetreatmentofpolypoidalchoroidalvasculopathy |