Cargando…

Coupled CP Decomposition of Simultaneous MEG-EEG Signals for Differentiating Oscillators During Photic Driving

Magnetoencephalography (MEG) and electroencephalography (EEG) are contemporary methods to investigate the function and organization of the brain. Simultaneously acquired MEG-EEG data are inherently multi-dimensional and exhibit coupling. This study uses a coupled tensor decomposition to extract the...

Descripción completa

Detalles Bibliográficos
Autores principales: Naskovska, Kristina, Lau, Stephan, Korobkov, Alexey A., Haueisen, Jens, Haardt, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7161426/
https://www.ncbi.nlm.nih.gov/pubmed/32327966
http://dx.doi.org/10.3389/fnins.2020.00261
_version_ 1783522954039001088
author Naskovska, Kristina
Lau, Stephan
Korobkov, Alexey A.
Haueisen, Jens
Haardt, Martin
author_facet Naskovska, Kristina
Lau, Stephan
Korobkov, Alexey A.
Haueisen, Jens
Haardt, Martin
author_sort Naskovska, Kristina
collection PubMed
description Magnetoencephalography (MEG) and electroencephalography (EEG) are contemporary methods to investigate the function and organization of the brain. Simultaneously acquired MEG-EEG data are inherently multi-dimensional and exhibit coupling. This study uses a coupled tensor decomposition to extract the signal sources from MEG-EEG during intermittent photic stimulation (IPS). We employ the Coupled Semi-Algebraic framework for approximate CP decomposition via SImultaneous matrix diagonalization (C-SECSI). After comparing its performance with alternative methods using simulated benchmark data, we apply it to MEG-EEG recordings of 12 participants during IPS with fractions of the individual alpha frequency between 0.4 and 1.3. In the benchmark tests, C-SECSI is more accurate than SECSI and alternative methods, especially in ill-conditioned scenarios, e.g., involving collinear factors or noise sources with different variances. The component field-maps allow us to separate physiologically meaningful oscillations of visually evoked brain activity from background signals. The frequency signatures of the components identify either an entrainment to the respective stimulation frequency or its first harmonic, or an oscillation in the individual alpha band or theta band. In the group analysis of both, MEG and EEG data, we observe a reciprocal relationship between alpha and theta band oscillations. The coupled tensor decomposition using C-SECSI is a robust, powerful method for the extraction of physiologically meaningful sources from multidimensional biomedical data. Unsupervised signal source extraction is an essential solution for rendering advanced multi-modal signal acquisition technology accessible to clinical diagnostics, pre-surgical planning, and brain computer interface applications.
format Online
Article
Text
id pubmed-7161426
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-71614262020-04-23 Coupled CP Decomposition of Simultaneous MEG-EEG Signals for Differentiating Oscillators During Photic Driving Naskovska, Kristina Lau, Stephan Korobkov, Alexey A. Haueisen, Jens Haardt, Martin Front Neurosci Neuroscience Magnetoencephalography (MEG) and electroencephalography (EEG) are contemporary methods to investigate the function and organization of the brain. Simultaneously acquired MEG-EEG data are inherently multi-dimensional and exhibit coupling. This study uses a coupled tensor decomposition to extract the signal sources from MEG-EEG during intermittent photic stimulation (IPS). We employ the Coupled Semi-Algebraic framework for approximate CP decomposition via SImultaneous matrix diagonalization (C-SECSI). After comparing its performance with alternative methods using simulated benchmark data, we apply it to MEG-EEG recordings of 12 participants during IPS with fractions of the individual alpha frequency between 0.4 and 1.3. In the benchmark tests, C-SECSI is more accurate than SECSI and alternative methods, especially in ill-conditioned scenarios, e.g., involving collinear factors or noise sources with different variances. The component field-maps allow us to separate physiologically meaningful oscillations of visually evoked brain activity from background signals. The frequency signatures of the components identify either an entrainment to the respective stimulation frequency or its first harmonic, or an oscillation in the individual alpha band or theta band. In the group analysis of both, MEG and EEG data, we observe a reciprocal relationship between alpha and theta band oscillations. The coupled tensor decomposition using C-SECSI is a robust, powerful method for the extraction of physiologically meaningful sources from multidimensional biomedical data. Unsupervised signal source extraction is an essential solution for rendering advanced multi-modal signal acquisition technology accessible to clinical diagnostics, pre-surgical planning, and brain computer interface applications. Frontiers Media S.A. 2020-04-09 /pmc/articles/PMC7161426/ /pubmed/32327966 http://dx.doi.org/10.3389/fnins.2020.00261 Text en Copyright © 2020 Naskovska, Lau, Korobkov, Haueisen and Haardt. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Naskovska, Kristina
Lau, Stephan
Korobkov, Alexey A.
Haueisen, Jens
Haardt, Martin
Coupled CP Decomposition of Simultaneous MEG-EEG Signals for Differentiating Oscillators During Photic Driving
title Coupled CP Decomposition of Simultaneous MEG-EEG Signals for Differentiating Oscillators During Photic Driving
title_full Coupled CP Decomposition of Simultaneous MEG-EEG Signals for Differentiating Oscillators During Photic Driving
title_fullStr Coupled CP Decomposition of Simultaneous MEG-EEG Signals for Differentiating Oscillators During Photic Driving
title_full_unstemmed Coupled CP Decomposition of Simultaneous MEG-EEG Signals for Differentiating Oscillators During Photic Driving
title_short Coupled CP Decomposition of Simultaneous MEG-EEG Signals for Differentiating Oscillators During Photic Driving
title_sort coupled cp decomposition of simultaneous meg-eeg signals for differentiating oscillators during photic driving
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7161426/
https://www.ncbi.nlm.nih.gov/pubmed/32327966
http://dx.doi.org/10.3389/fnins.2020.00261
work_keys_str_mv AT naskovskakristina coupledcpdecompositionofsimultaneousmegeegsignalsfordifferentiatingoscillatorsduringphoticdriving
AT laustephan coupledcpdecompositionofsimultaneousmegeegsignalsfordifferentiatingoscillatorsduringphoticdriving
AT korobkovalexeya coupledcpdecompositionofsimultaneousmegeegsignalsfordifferentiatingoscillatorsduringphoticdriving
AT haueisenjens coupledcpdecompositionofsimultaneousmegeegsignalsfordifferentiatingoscillatorsduringphoticdriving
AT haardtmartin coupledcpdecompositionofsimultaneousmegeegsignalsfordifferentiatingoscillatorsduringphoticdriving