Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report

A 49-year-old man with CTEPH (pre-procedural mean pulmonary artery pressure: 36 mmHg) underwent balloon pulmonary angioplasty. Chronic total occlusion of the left inferior pulmonary artery trunk was observed. To evaluate the collateral vessels of the chronic total occlusion, 4D-CTA was performed. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Tamura, Masashi, Kawakami, Takashi, Yamada, Yoshitake, Kataoka, Masaharu, Nakatsuka, Seishi, Fukuda, Keiichi, Jinzaki, Masahiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7163237/
https://www.ncbi.nlm.nih.gov/pubmed/32328236
http://dx.doi.org/10.1177/2045894019881065
_version_ 1783523177076359168
author Tamura, Masashi
Kawakami, Takashi
Yamada, Yoshitake
Kataoka, Masaharu
Nakatsuka, Seishi
Fukuda, Keiichi
Jinzaki, Masahiro
author_facet Tamura, Masashi
Kawakami, Takashi
Yamada, Yoshitake
Kataoka, Masaharu
Nakatsuka, Seishi
Fukuda, Keiichi
Jinzaki, Masahiro
author_sort Tamura, Masashi
collection PubMed
description A 49-year-old man with CTEPH (pre-procedural mean pulmonary artery pressure: 36 mmHg) underwent balloon pulmonary angioplasty. Chronic total occlusion of the left inferior pulmonary artery trunk was observed. To evaluate the collateral vessels of the chronic total occlusion, 4D-CTA was performed. The examination was performed using a 256-row detector CT system using the test bolus tracking method. 4D-CTA showed the bronchial artery-to-left inferior pulmonary artery collateral supply, which was confirmed by a selective bronchial artery angiography. The patient’s symptoms improved with balloon pulmonary angioplasty of the other stenotic lesions. 4D-CTA can noninvasively evaluate the anatomy and hemodynamics of multiple systemic collaterals simultaneously. This technique can support interventions in systemic artery-to-pulmonary artery collaterals, such as embolization, and could be helpful in challenging balloon pulmonary angioplasty interventions for chronic total occlusion to identify vessel structures distal to the chronic total occlusion and collateral channels for a retrograde approach.
format Online
Article
Text
id pubmed-7163237
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-71632372020-04-23 Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report Tamura, Masashi Kawakami, Takashi Yamada, Yoshitake Kataoka, Masaharu Nakatsuka, Seishi Fukuda, Keiichi Jinzaki, Masahiro Pulm Circ Case Report A 49-year-old man with CTEPH (pre-procedural mean pulmonary artery pressure: 36 mmHg) underwent balloon pulmonary angioplasty. Chronic total occlusion of the left inferior pulmonary artery trunk was observed. To evaluate the collateral vessels of the chronic total occlusion, 4D-CTA was performed. The examination was performed using a 256-row detector CT system using the test bolus tracking method. 4D-CTA showed the bronchial artery-to-left inferior pulmonary artery collateral supply, which was confirmed by a selective bronchial artery angiography. The patient’s symptoms improved with balloon pulmonary angioplasty of the other stenotic lesions. 4D-CTA can noninvasively evaluate the anatomy and hemodynamics of multiple systemic collaterals simultaneously. This technique can support interventions in systemic artery-to-pulmonary artery collaterals, such as embolization, and could be helpful in challenging balloon pulmonary angioplasty interventions for chronic total occlusion to identify vessel structures distal to the chronic total occlusion and collateral channels for a retrograde approach. SAGE Publications 2020-04-16 /pmc/articles/PMC7163237/ /pubmed/32328236 http://dx.doi.org/10.1177/2045894019881065 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Case Report
Tamura, Masashi
Kawakami, Takashi
Yamada, Yoshitake
Kataoka, Masaharu
Nakatsuka, Seishi
Fukuda, Keiichi
Jinzaki, Masahiro
Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report
title Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report
title_full Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report
title_fullStr Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report
title_full_unstemmed Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report
title_short Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report
title_sort successful depiction of systemic collateral supply to pulmonary artery in cteph using time-resolved 4d ct angiography: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7163237/
https://www.ncbi.nlm.nih.gov/pubmed/32328236
http://dx.doi.org/10.1177/2045894019881065
work_keys_str_mv AT tamuramasashi successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport
AT kawakamitakashi successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport
AT yamadayoshitake successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport
AT kataokamasaharu successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport
AT nakatsukaseishi successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport
AT fukudakeiichi successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport
AT jinzakimasahiro successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport