Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report
A 49-year-old man with CTEPH (pre-procedural mean pulmonary artery pressure: 36 mmHg) underwent balloon pulmonary angioplasty. Chronic total occlusion of the left inferior pulmonary artery trunk was observed. To evaluate the collateral vessels of the chronic total occlusion, 4D-CTA was performed. Th...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7163237/ https://www.ncbi.nlm.nih.gov/pubmed/32328236 http://dx.doi.org/10.1177/2045894019881065 |
_version_ | 1783523177076359168 |
---|---|
author | Tamura, Masashi Kawakami, Takashi Yamada, Yoshitake Kataoka, Masaharu Nakatsuka, Seishi Fukuda, Keiichi Jinzaki, Masahiro |
author_facet | Tamura, Masashi Kawakami, Takashi Yamada, Yoshitake Kataoka, Masaharu Nakatsuka, Seishi Fukuda, Keiichi Jinzaki, Masahiro |
author_sort | Tamura, Masashi |
collection | PubMed |
description | A 49-year-old man with CTEPH (pre-procedural mean pulmonary artery pressure: 36 mmHg) underwent balloon pulmonary angioplasty. Chronic total occlusion of the left inferior pulmonary artery trunk was observed. To evaluate the collateral vessels of the chronic total occlusion, 4D-CTA was performed. The examination was performed using a 256-row detector CT system using the test bolus tracking method. 4D-CTA showed the bronchial artery-to-left inferior pulmonary artery collateral supply, which was confirmed by a selective bronchial artery angiography. The patient’s symptoms improved with balloon pulmonary angioplasty of the other stenotic lesions. 4D-CTA can noninvasively evaluate the anatomy and hemodynamics of multiple systemic collaterals simultaneously. This technique can support interventions in systemic artery-to-pulmonary artery collaterals, such as embolization, and could be helpful in challenging balloon pulmonary angioplasty interventions for chronic total occlusion to identify vessel structures distal to the chronic total occlusion and collateral channels for a retrograde approach. |
format | Online Article Text |
id | pubmed-7163237 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-71632372020-04-23 Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report Tamura, Masashi Kawakami, Takashi Yamada, Yoshitake Kataoka, Masaharu Nakatsuka, Seishi Fukuda, Keiichi Jinzaki, Masahiro Pulm Circ Case Report A 49-year-old man with CTEPH (pre-procedural mean pulmonary artery pressure: 36 mmHg) underwent balloon pulmonary angioplasty. Chronic total occlusion of the left inferior pulmonary artery trunk was observed. To evaluate the collateral vessels of the chronic total occlusion, 4D-CTA was performed. The examination was performed using a 256-row detector CT system using the test bolus tracking method. 4D-CTA showed the bronchial artery-to-left inferior pulmonary artery collateral supply, which was confirmed by a selective bronchial artery angiography. The patient’s symptoms improved with balloon pulmonary angioplasty of the other stenotic lesions. 4D-CTA can noninvasively evaluate the anatomy and hemodynamics of multiple systemic collaterals simultaneously. This technique can support interventions in systemic artery-to-pulmonary artery collaterals, such as embolization, and could be helpful in challenging balloon pulmonary angioplasty interventions for chronic total occlusion to identify vessel structures distal to the chronic total occlusion and collateral channels for a retrograde approach. SAGE Publications 2020-04-16 /pmc/articles/PMC7163237/ /pubmed/32328236 http://dx.doi.org/10.1177/2045894019881065 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Case Report Tamura, Masashi Kawakami, Takashi Yamada, Yoshitake Kataoka, Masaharu Nakatsuka, Seishi Fukuda, Keiichi Jinzaki, Masahiro Successful depiction of systemic collateral supply to pulmonary artery in CTEPH using time-resolved 4D CT angiography: a case report |
title | Successful depiction of systemic collateral supply to pulmonary
artery in CTEPH using time-resolved 4D CT angiography: a case
report |
title_full | Successful depiction of systemic collateral supply to pulmonary
artery in CTEPH using time-resolved 4D CT angiography: a case
report |
title_fullStr | Successful depiction of systemic collateral supply to pulmonary
artery in CTEPH using time-resolved 4D CT angiography: a case
report |
title_full_unstemmed | Successful depiction of systemic collateral supply to pulmonary
artery in CTEPH using time-resolved 4D CT angiography: a case
report |
title_short | Successful depiction of systemic collateral supply to pulmonary
artery in CTEPH using time-resolved 4D CT angiography: a case
report |
title_sort | successful depiction of systemic collateral supply to pulmonary
artery in cteph using time-resolved 4d ct angiography: a case
report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7163237/ https://www.ncbi.nlm.nih.gov/pubmed/32328236 http://dx.doi.org/10.1177/2045894019881065 |
work_keys_str_mv | AT tamuramasashi successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport AT kawakamitakashi successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport AT yamadayoshitake successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport AT kataokamasaharu successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport AT nakatsukaseishi successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport AT fukudakeiichi successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport AT jinzakimasahiro successfuldepictionofsystemiccollateralsupplytopulmonaryarteryinctephusingtimeresolved4dctangiographyacasereport |