Cargando…
Non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers
PURPOSE: The aim of this study was to determine the inter- and intra-observer reliability of knee laxity assessment using a non-invasive navigation system in a population of healthy young athletes. It was hypothesized that knee laxity parameters recorded using non-invasive computer navigation would...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7163905/ https://www.ncbi.nlm.nih.gov/pubmed/32303912 http://dx.doi.org/10.1186/s40634-020-00239-5 |
_version_ | 1783523228155641856 |
---|---|
author | Monaco, Edoardo Bruni, Giorgio Lo Torto, Sara Carrozzo, Alessandro Daggett, Matthew Annibaldi, Alessandro Saithna, Adnan Ferretti, Andrea |
author_facet | Monaco, Edoardo Bruni, Giorgio Lo Torto, Sara Carrozzo, Alessandro Daggett, Matthew Annibaldi, Alessandro Saithna, Adnan Ferretti, Andrea |
author_sort | Monaco, Edoardo |
collection | PubMed |
description | PURPOSE: The aim of this study was to determine the inter- and intra-observer reliability of knee laxity assessment using a non-invasive navigation system in a population of healthy young athletes. It was hypothesized that knee laxity parameters recorded using non-invasive computer navigation would demonstrate good inter- and intra-observer reliability. METHODS: Healthy volunteers aged between 18 to 30 years were recruited to the study. Static and dynamic knee laxity parameters including anterior tibial translation and tibial rotation during the pivot shift test were recorded on awake patients using non-invasive computer navigation by two independent observers: at the first visit each athlete was evaluated by the consultant and resident surgeons independently; 6 weeks after the first visit all the participants were re-tested only by the resident surgeon. Inter- and intra-observer reliability was calculated and then interpreted according to Cicchetti’s criteria. RESULTS: One hundred healthy volunteers were recruited to the study, of these 38 were women (38%), and the average age was 25.5 ± 2.4 years. According to Cicchetti’s criteria the intra- and inter-observer reliability for static measurements were fair for anterior tibial translation (0.572 and 0.529, respectively) and excellent for total passive tibial rotation (0.859 and 0.883, respectively). For the dynamic measurements of translation and rotation during the pivot shift maneuver both measurements demonstrated good to excellent reliability with intra and inter observer reliability ranging from 0.684 to 0.936. CONCLUSION: Non-invasive navigation for the assessment of knee laxity is associated with fair to excellent inter- and intra-observer reliability in a population of healthy volunteers. |
format | Online Article Text |
id | pubmed-7163905 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-71639052020-04-24 Non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers Monaco, Edoardo Bruni, Giorgio Lo Torto, Sara Carrozzo, Alessandro Daggett, Matthew Annibaldi, Alessandro Saithna, Adnan Ferretti, Andrea J Exp Orthop Research PURPOSE: The aim of this study was to determine the inter- and intra-observer reliability of knee laxity assessment using a non-invasive navigation system in a population of healthy young athletes. It was hypothesized that knee laxity parameters recorded using non-invasive computer navigation would demonstrate good inter- and intra-observer reliability. METHODS: Healthy volunteers aged between 18 to 30 years were recruited to the study. Static and dynamic knee laxity parameters including anterior tibial translation and tibial rotation during the pivot shift test were recorded on awake patients using non-invasive computer navigation by two independent observers: at the first visit each athlete was evaluated by the consultant and resident surgeons independently; 6 weeks after the first visit all the participants were re-tested only by the resident surgeon. Inter- and intra-observer reliability was calculated and then interpreted according to Cicchetti’s criteria. RESULTS: One hundred healthy volunteers were recruited to the study, of these 38 were women (38%), and the average age was 25.5 ± 2.4 years. According to Cicchetti’s criteria the intra- and inter-observer reliability for static measurements were fair for anterior tibial translation (0.572 and 0.529, respectively) and excellent for total passive tibial rotation (0.859 and 0.883, respectively). For the dynamic measurements of translation and rotation during the pivot shift maneuver both measurements demonstrated good to excellent reliability with intra and inter observer reliability ranging from 0.684 to 0.936. CONCLUSION: Non-invasive navigation for the assessment of knee laxity is associated with fair to excellent inter- and intra-observer reliability in a population of healthy volunteers. Springer Berlin Heidelberg 2020-04-17 /pmc/articles/PMC7163905/ /pubmed/32303912 http://dx.doi.org/10.1186/s40634-020-00239-5 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Research Monaco, Edoardo Bruni, Giorgio Lo Torto, Sara Carrozzo, Alessandro Daggett, Matthew Annibaldi, Alessandro Saithna, Adnan Ferretti, Andrea Non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers |
title | Non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers |
title_full | Non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers |
title_fullStr | Non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers |
title_full_unstemmed | Non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers |
title_short | Non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers |
title_sort | non-invasive computer navigation can quantify the pivot shift maneuver with good to excellent reliability in healthy volunteers |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7163905/ https://www.ncbi.nlm.nih.gov/pubmed/32303912 http://dx.doi.org/10.1186/s40634-020-00239-5 |
work_keys_str_mv | AT monacoedoardo noninvasivecomputernavigationcanquantifythepivotshiftmaneuverwithgoodtoexcellentreliabilityinhealthyvolunteers AT brunigiorgio noninvasivecomputernavigationcanquantifythepivotshiftmaneuverwithgoodtoexcellentreliabilityinhealthyvolunteers AT lotortosara noninvasivecomputernavigationcanquantifythepivotshiftmaneuverwithgoodtoexcellentreliabilityinhealthyvolunteers AT carrozzoalessandro noninvasivecomputernavigationcanquantifythepivotshiftmaneuverwithgoodtoexcellentreliabilityinhealthyvolunteers AT daggettmatthew noninvasivecomputernavigationcanquantifythepivotshiftmaneuverwithgoodtoexcellentreliabilityinhealthyvolunteers AT annibaldialessandro noninvasivecomputernavigationcanquantifythepivotshiftmaneuverwithgoodtoexcellentreliabilityinhealthyvolunteers AT saithnaadnan noninvasivecomputernavigationcanquantifythepivotshiftmaneuverwithgoodtoexcellentreliabilityinhealthyvolunteers AT ferrettiandrea noninvasivecomputernavigationcanquantifythepivotshiftmaneuverwithgoodtoexcellentreliabilityinhealthyvolunteers |