Shear-Wave Elastography Variability Analysis and Relation with Kidney Allograft Dysfunction: A Single-Center Study
Shear-wave elastography (SWE) showed the absence or presence of significant differences among stable kidney allograft function and allograft dysfunction. We evaluated the variability of kidney allograft stiffness in relation to allograft dysfunction, respectively, in terms of a correlation of stiffn...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7169400/ https://www.ncbi.nlm.nih.gov/pubmed/31941112 http://dx.doi.org/10.3390/diagnostics10010041 |
Sumario: | Shear-wave elastography (SWE) showed the absence or presence of significant differences among stable kidney allograft function and allograft dysfunction. We evaluated the variability of kidney allograft stiffness in relation to allograft dysfunction, respectively, in terms of a correlation of stiffness with patients’ characteristics. A single-center prospective study on patients who had undergone renal transplantation was conducted between October 2017 and November 2018. Patients were clinically classified as having a stable allograft function or allograft dysfunction. SWE examinations performed by the same radiologist with a LOGIQ E9 were evaluated. Ten measurements were done for Young’s modulus (kPa) at the level of allograft cortex and another ten at the level of medulla. Eighty-three SWE examinations from 63 patients, 69 stable allografts, and 14 allografts with dysfunction were included in the analysis. The intra-examinations stiffness showed high variability, with the quantile covariation coefficient ranging from 2.21% to 45.04%. The inter-examinations stiffness showed heterogeneity (from 28.66% to 42.38%). The kidney allograft cortex stiffness showed significantly higher values in cases with dysfunction (median = 28.70 kPa, interquartile range (IQR) = (25.68–31.98) kPa) as compared to those with stable function (median = 20.99 kPa, interquartile range = (16.08–27.68) kPa; p-value = 0.0142). Allograft tissue stiffness (both cortex and medulla) was significantly negatively correlated with body mass index (−0.44, p-value < 0.0001 for allograft cortex and −0.42, p-value = 0.0001 for allograft medulla), and positively correlated with Proteinuria/Creatinuria ratio (0.33, p-value = 0.0021 for allograft cortex and 0.28, p-value = 0.0105 for allograft medulla) but remained statistically significant only in cases with stable function. The cortical tissue stiffness proved significantly higher values for patients with allograft dysfunction as compared to patients with stable function, but to evolve as an additional tool for the evaluation of patients with a kidney transplant and to change the clinical practice, more extensive studies are needed. |
---|