Cargando…

Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT

PURPOSE: We compare the effect of tube current modulation (TCM) and fixed tube current (FTC) on size‐specific dose estimates (SSDE) and image quality in lung cancer screening with low‐dose CT (LDCT) for patients of all sizes. METHODS: Initially, 107 lung screening examinations were performed using F...

Descripción completa

Detalles Bibliográficos
Autores principales: Barreto, Izabella, Verma, Nupur, Quails, Nathan, Olguin, Catherine, Correa, Nathalie, Mohammed, Tan‐Lucien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7170290/
https://www.ncbi.nlm.nih.gov/pubmed/32250062
http://dx.doi.org/10.1002/acm2.12857
_version_ 1783523864394858496
author Barreto, Izabella
Verma, Nupur
Quails, Nathan
Olguin, Catherine
Correa, Nathalie
Mohammed, Tan‐Lucien
author_facet Barreto, Izabella
Verma, Nupur
Quails, Nathan
Olguin, Catherine
Correa, Nathalie
Mohammed, Tan‐Lucien
author_sort Barreto, Izabella
collection PubMed
description PURPOSE: We compare the effect of tube current modulation (TCM) and fixed tube current (FTC) on size‐specific dose estimates (SSDE) and image quality in lung cancer screening with low‐dose CT (LDCT) for patients of all sizes. METHODS: Initially, 107 lung screening examinations were performed using FTC, which satisfied the Centers for Medicare & Medicaid Services' volumetric CT dose index (CTDI(vol)) limit of 3.0 mGy for standard‐sized patients. Following protocol modification, 287 examinations were performed using TCM. Patient size and examination parameters were collected and water‐equivalent diameter (D(w)) and SSDE were determined for each patient. Regression models were used to correlate CTDI(vol) and SSDE with D(w). Objective and subjective image quality were measured in 20 patients who had consecutive annual screenings with both FTC and TCM. RESULTS: CTDI(vol) was 2.3 mGy for all FTC scans and increased exponentially with D(w) (range = 0.96–4.50 mGy, R(2) = 0.73) for TCM scans. As patient D(w) increased, SSDE decreased for FTC examinations (R(2) = 1) and increased for TCM examinations (R(2) = 0.54). Image quality measurements were superior with FTC for smaller sized patients and with TCM for larger sized patients (R(2) > 0.5, P < 0.005). Radiologist graded all images acceptable for diagnostic evaluation of lung cancer screening. CONCLUSION: Although FTC protocol offered a consistently low CTDI(vol) for all patients, it yielded unnecessarily high SSDE for small patients and increased image noise for large patients. Lung cancer screening with LDCT using TCM produces radiation doses that are appropriately reduced for small patients and increased for large patients with diagnostic image quality for all patients.
format Online
Article
Text
id pubmed-7170290
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-71702902020-04-21 Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT Barreto, Izabella Verma, Nupur Quails, Nathan Olguin, Catherine Correa, Nathalie Mohammed, Tan‐Lucien J Appl Clin Med Phys Medical Imaging PURPOSE: We compare the effect of tube current modulation (TCM) and fixed tube current (FTC) on size‐specific dose estimates (SSDE) and image quality in lung cancer screening with low‐dose CT (LDCT) for patients of all sizes. METHODS: Initially, 107 lung screening examinations were performed using FTC, which satisfied the Centers for Medicare & Medicaid Services' volumetric CT dose index (CTDI(vol)) limit of 3.0 mGy for standard‐sized patients. Following protocol modification, 287 examinations were performed using TCM. Patient size and examination parameters were collected and water‐equivalent diameter (D(w)) and SSDE were determined for each patient. Regression models were used to correlate CTDI(vol) and SSDE with D(w). Objective and subjective image quality were measured in 20 patients who had consecutive annual screenings with both FTC and TCM. RESULTS: CTDI(vol) was 2.3 mGy for all FTC scans and increased exponentially with D(w) (range = 0.96–4.50 mGy, R(2) = 0.73) for TCM scans. As patient D(w) increased, SSDE decreased for FTC examinations (R(2) = 1) and increased for TCM examinations (R(2) = 0.54). Image quality measurements were superior with FTC for smaller sized patients and with TCM for larger sized patients (R(2) > 0.5, P < 0.005). Radiologist graded all images acceptable for diagnostic evaluation of lung cancer screening. CONCLUSION: Although FTC protocol offered a consistently low CTDI(vol) for all patients, it yielded unnecessarily high SSDE for small patients and increased image noise for large patients. Lung cancer screening with LDCT using TCM produces radiation doses that are appropriately reduced for small patients and increased for large patients with diagnostic image quality for all patients. John Wiley and Sons Inc. 2020-04-06 /pmc/articles/PMC7170290/ /pubmed/32250062 http://dx.doi.org/10.1002/acm2.12857 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Barreto, Izabella
Verma, Nupur
Quails, Nathan
Olguin, Catherine
Correa, Nathalie
Mohammed, Tan‐Lucien
Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT
title Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT
title_full Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT
title_fullStr Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT
title_full_unstemmed Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT
title_short Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT
title_sort patient size matters: effect of tube current modulation on size‐specific dose estimates (ssde) and image quality in low‐dose lung cancer screening ct
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7170290/
https://www.ncbi.nlm.nih.gov/pubmed/32250062
http://dx.doi.org/10.1002/acm2.12857
work_keys_str_mv AT barretoizabella patientsizematterseffectoftubecurrentmodulationonsizespecificdoseestimatesssdeandimagequalityinlowdoselungcancerscreeningct
AT vermanupur patientsizematterseffectoftubecurrentmodulationonsizespecificdoseestimatesssdeandimagequalityinlowdoselungcancerscreeningct
AT quailsnathan patientsizematterseffectoftubecurrentmodulationonsizespecificdoseestimatesssdeandimagequalityinlowdoselungcancerscreeningct
AT olguincatherine patientsizematterseffectoftubecurrentmodulationonsizespecificdoseestimatesssdeandimagequalityinlowdoselungcancerscreeningct
AT correanathalie patientsizematterseffectoftubecurrentmodulationonsizespecificdoseestimatesssdeandimagequalityinlowdoselungcancerscreeningct
AT mohammedtanlucien patientsizematterseffectoftubecurrentmodulationonsizespecificdoseestimatesssdeandimagequalityinlowdoselungcancerscreeningct