Cargando…

Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study

BACKGROUND: Since the introduction of endovascular aortic repair (EVAR) for treatment of abdominal aortic aneurysms (AAAs), progressive improvements in results have been achieved. However, conventional bifurcated stent grafts have been proven to have a nonnegligible risk of failure and secondary int...

Descripción completa

Detalles Bibliográficos
Autores principales: Silingardi, Roberto, Sirignano, Pasqualino, Andreoli, Francesco, Mansour, Wassim, Migliari, Mattia, Speziale, Francesco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7171559/
https://www.ncbi.nlm.nih.gov/pubmed/32250278
http://dx.doi.org/10.2196/16959
_version_ 1783524095195873280
author Silingardi, Roberto
Sirignano, Pasqualino
Andreoli, Francesco
Mansour, Wassim
Migliari, Mattia
Speziale, Francesco
author_facet Silingardi, Roberto
Sirignano, Pasqualino
Andreoli, Francesco
Mansour, Wassim
Migliari, Mattia
Speziale, Francesco
author_sort Silingardi, Roberto
collection PubMed
description BACKGROUND: Since the introduction of endovascular aortic repair (EVAR) for treatment of abdominal aortic aneurysms (AAAs), progressive improvements in results have been achieved. However, conventional bifurcated stent grafts have been proven to have a nonnegligible risk of failure and secondary intervention, principally due to the lack of adequate proximal sealing. The unique AFX 2 Endovascular AAA System (Endologix, Irvine, CA) unibody device, which provides different sealing and fixation features compared with conventional devices, seems to overcome these limitations. OBJECTIVE: The aim of this study is to evaluate intraoperative, perioperative, and postoperative results in patients treated with the AFX 2 Endovascular AAA System endografts for elective AAA repair in a large cohort of consecutive patients. METHODS: All eligible EVAR patients will be included in this observational, multicenter, prospective, nonrandomized study. The number of patients to be enrolled is 500. RESULTS: The primary endpoint of the study is to evaluate the technical and clinical success of EVAR with unibody endografts in short- (90-day), mid- (1-year), and long-term (5-year) follow-up periods. The following secondary endpoints will also be addressed: operative time, intraoperative radiation exposure, contrast medium usage, AAA sac shrinkage at 12-month and 5-year follow-up, and any potential role of patients’ baseline characteristics and device configuration on primary endpoint. The actual start date of the investigation was November 2019. The final patient is expected to be treated by the end of December 2020, and the estimated study completion date is December 2025. CONCLUSIONS: This study will provide verified real-world data on AAAs treated by AFX 2 endografts and followed for a long-term interval. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/16959
format Online
Article
Text
id pubmed-7171559
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-71715592020-04-28 Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study Silingardi, Roberto Sirignano, Pasqualino Andreoli, Francesco Mansour, Wassim Migliari, Mattia Speziale, Francesco JMIR Res Protoc Protocol BACKGROUND: Since the introduction of endovascular aortic repair (EVAR) for treatment of abdominal aortic aneurysms (AAAs), progressive improvements in results have been achieved. However, conventional bifurcated stent grafts have been proven to have a nonnegligible risk of failure and secondary intervention, principally due to the lack of adequate proximal sealing. The unique AFX 2 Endovascular AAA System (Endologix, Irvine, CA) unibody device, which provides different sealing and fixation features compared with conventional devices, seems to overcome these limitations. OBJECTIVE: The aim of this study is to evaluate intraoperative, perioperative, and postoperative results in patients treated with the AFX 2 Endovascular AAA System endografts for elective AAA repair in a large cohort of consecutive patients. METHODS: All eligible EVAR patients will be included in this observational, multicenter, prospective, nonrandomized study. The number of patients to be enrolled is 500. RESULTS: The primary endpoint of the study is to evaluate the technical and clinical success of EVAR with unibody endografts in short- (90-day), mid- (1-year), and long-term (5-year) follow-up periods. The following secondary endpoints will also be addressed: operative time, intraoperative radiation exposure, contrast medium usage, AAA sac shrinkage at 12-month and 5-year follow-up, and any potential role of patients’ baseline characteristics and device configuration on primary endpoint. The actual start date of the investigation was November 2019. The final patient is expected to be treated by the end of December 2020, and the estimated study completion date is December 2025. CONCLUSIONS: This study will provide verified real-world data on AAAs treated by AFX 2 endografts and followed for a long-term interval. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/16959 JMIR Publications 2020-04-06 /pmc/articles/PMC7171559/ /pubmed/32250278 http://dx.doi.org/10.2196/16959 Text en ©Roberto Silingardi, Pasqualino Sirignano, Francesco Andreoli, Wassim Mansour, Mattia Migliari, Francesco Speziale, LIVE Study Collaborators. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 06.04.2020. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Research Protocols, is properly cited. The complete bibliographic information, a link to the original publication on http://www.researchprotocols.org, as well as this copyright and license information must be included.
spellingShingle Protocol
Silingardi, Roberto
Sirignano, Pasqualino
Andreoli, Francesco
Mansour, Wassim
Migliari, Mattia
Speziale, Francesco
Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study
title Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study
title_full Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study
title_fullStr Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study
title_full_unstemmed Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study
title_short Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study
title_sort unibody endograft using afx 2 for less invasive and faster endovascular aortic repair: protocol for a multicenter nonrandomized study
topic Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7171559/
https://www.ncbi.nlm.nih.gov/pubmed/32250278
http://dx.doi.org/10.2196/16959
work_keys_str_mv AT silingardiroberto unibodyendograftusingafx2forlessinvasiveandfasterendovascularaorticrepairprotocolforamulticenternonrandomizedstudy
AT sirignanopasqualino unibodyendograftusingafx2forlessinvasiveandfasterendovascularaorticrepairprotocolforamulticenternonrandomizedstudy
AT andreolifrancesco unibodyendograftusingafx2forlessinvasiveandfasterendovascularaorticrepairprotocolforamulticenternonrandomizedstudy
AT mansourwassim unibodyendograftusingafx2forlessinvasiveandfasterendovascularaorticrepairprotocolforamulticenternonrandomizedstudy
AT migliarimattia unibodyendograftusingafx2forlessinvasiveandfasterendovascularaorticrepairprotocolforamulticenternonrandomizedstudy
AT spezialefrancesco unibodyendograftusingafx2forlessinvasiveandfasterendovascularaorticrepairprotocolforamulticenternonrandomizedstudy
AT unibodyendograftusingafx2forlessinvasiveandfasterendovascularaorticrepairprotocolforamulticenternonrandomizedstudy