Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing
AIM: Current pricing of commercial mechanical ventilators in low-/middle-income countries (LMICs) markedly restricts their availability, and consequently a considerable number of patients with acute/chronic respiratory failure cannot be adequately treated. Our aim was to design and test an affordabl...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
European Respiratory Society
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7173672/ https://www.ncbi.nlm.nih.gov/pubmed/32312862 http://dx.doi.org/10.1183/13993003.00846-2020 |
_version_ | 1783524500582694912 |
---|---|
author | Garmendia, Onintza Rodríguez-Lazaro, Miguel A. Otero, Jorge Phan, Phuong Stoyanova, Alexandrina Dinh-Xuan, Anh Tuan Gozal, David Navajas, Daniel Montserrat, Josep M. Farré, Ramon |
author_facet | Garmendia, Onintza Rodríguez-Lazaro, Miguel A. Otero, Jorge Phan, Phuong Stoyanova, Alexandrina Dinh-Xuan, Anh Tuan Gozal, David Navajas, Daniel Montserrat, Josep M. Farré, Ramon |
author_sort | Garmendia, Onintza |
collection | PubMed |
description | AIM: Current pricing of commercial mechanical ventilators in low-/middle-income countries (LMICs) markedly restricts their availability, and consequently a considerable number of patients with acute/chronic respiratory failure cannot be adequately treated. Our aim was to design and test an affordable and easy-to-build noninvasive bilevel pressure ventilator to allow a reduction in the serious shortage of ventilators in LMICs. METHODS: The ventilator was built using off-the-shelf materials available via e-commerce and was based on a high-pressure blower, two pressure transducers and an Arduino Nano controller with a digital display (total retail cost <75 USD), with construction details provided open source for free replication. The ventilator was evaluated, and compared with a commercially available device (Lumis 150 ventilator; Resmed, San Diego, CA, USA): 1) in the bench setting using an actively breathing patient simulator mimicking a range of obstructive/restrictive diseases; and b) in 12 healthy volunteers wearing high airway resistance and thoracic/abdominal bands to mimic obstructive/restrictive patients. RESULTS: The designed ventilator provided inspiratory/expiratory pressures up to 20/10 cmH(2)O, respectively, with no faulty triggering or cycling; both in the bench test and in volunteers. The breathing difficulty score rated (1–10 scale) by the loaded breathing subjects was significantly (p<0.005) decreased from 5.45±1.68 without support to 2.83±1.66 when using the prototype ventilator, which showed no difference with the commercial device (2.80±1.48; p=1.000). CONCLUSION: The low-cost, easy-to-build noninvasive ventilator performs similarly to a high-quality commercial device, with its open-source hardware description, which will allow for free replication and use in LMICs, facilitating application of this life-saving therapy to patients who otherwise could not be treated. |
format | Online Article Text |
id | pubmed-7173672 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | European Respiratory Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-71736722020-04-21 Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing Garmendia, Onintza Rodríguez-Lazaro, Miguel A. Otero, Jorge Phan, Phuong Stoyanova, Alexandrina Dinh-Xuan, Anh Tuan Gozal, David Navajas, Daniel Montserrat, Josep M. Farré, Ramon Eur Respir J Original Articles AIM: Current pricing of commercial mechanical ventilators in low-/middle-income countries (LMICs) markedly restricts their availability, and consequently a considerable number of patients with acute/chronic respiratory failure cannot be adequately treated. Our aim was to design and test an affordable and easy-to-build noninvasive bilevel pressure ventilator to allow a reduction in the serious shortage of ventilators in LMICs. METHODS: The ventilator was built using off-the-shelf materials available via e-commerce and was based on a high-pressure blower, two pressure transducers and an Arduino Nano controller with a digital display (total retail cost <75 USD), with construction details provided open source for free replication. The ventilator was evaluated, and compared with a commercially available device (Lumis 150 ventilator; Resmed, San Diego, CA, USA): 1) in the bench setting using an actively breathing patient simulator mimicking a range of obstructive/restrictive diseases; and b) in 12 healthy volunteers wearing high airway resistance and thoracic/abdominal bands to mimic obstructive/restrictive patients. RESULTS: The designed ventilator provided inspiratory/expiratory pressures up to 20/10 cmH(2)O, respectively, with no faulty triggering or cycling; both in the bench test and in volunteers. The breathing difficulty score rated (1–10 scale) by the loaded breathing subjects was significantly (p<0.005) decreased from 5.45±1.68 without support to 2.83±1.66 when using the prototype ventilator, which showed no difference with the commercial device (2.80±1.48; p=1.000). CONCLUSION: The low-cost, easy-to-build noninvasive ventilator performs similarly to a high-quality commercial device, with its open-source hardware description, which will allow for free replication and use in LMICs, facilitating application of this life-saving therapy to patients who otherwise could not be treated. European Respiratory Society 2020-06-04 /pmc/articles/PMC7173672/ /pubmed/32312862 http://dx.doi.org/10.1183/13993003.00846-2020 Text en Copyright ©ERS 2020 http://creativecommons.org/licenses/by-nc/4.0/This version is distributed under the terms of the Creative Commons Attribution Non-Commercial Licence 4.0. |
spellingShingle | Original Articles Garmendia, Onintza Rodríguez-Lazaro, Miguel A. Otero, Jorge Phan, Phuong Stoyanova, Alexandrina Dinh-Xuan, Anh Tuan Gozal, David Navajas, Daniel Montserrat, Josep M. Farré, Ramon Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing |
title | Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing |
title_full | Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing |
title_fullStr | Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing |
title_full_unstemmed | Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing |
title_short | Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing |
title_sort | low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7173672/ https://www.ncbi.nlm.nih.gov/pubmed/32312862 http://dx.doi.org/10.1183/13993003.00846-2020 |
work_keys_str_mv | AT garmendiaonintza lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT rodriguezlazaromiguela lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT oterojorge lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT phanphuong lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT stoyanovaalexandrina lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT dinhxuananhtuan lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT gozaldavid lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT navajasdaniel lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT montserratjosepm lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting AT farreramon lowcosteasytobuildnoninvasivepressuresupportventilatorforunderresourcedregionsopensourcehardwaredescriptionperformanceandfeasibilitytesting |