Cargando…

Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing

In transcranial penetration, ultrasound undergoes refraction, diffraction, multi-reflection, and mode conversion. These factors lead to phase aberration and waveform distortion, which impede the realization of transcranial ultrasonic imaging and therapy. Ray tracing has been used to correct the phas...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Chen, Li, Dan, Xu, Feng, Li, Ying, Liu, Chengcheng, Ta, Dean
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7174677/
https://www.ncbi.nlm.nih.gov/pubmed/32351351
http://dx.doi.org/10.3389/fnins.2020.00317
_version_ 1783524674814083072
author Jiang, Chen
Li, Dan
Xu, Feng
Li, Ying
Liu, Chengcheng
Ta, Dean
author_facet Jiang, Chen
Li, Dan
Xu, Feng
Li, Ying
Liu, Chengcheng
Ta, Dean
author_sort Jiang, Chen
collection PubMed
description In transcranial penetration, ultrasound undergoes refraction, diffraction, multi-reflection, and mode conversion. These factors lead to phase aberration and waveform distortion, which impede the realization of transcranial ultrasonic imaging and therapy. Ray tracing has been used to correct the phase aberration and is computationally more efficient than traditional full-wave simulation. However, when ray tracing has been used for transcranial investigation, it has generally been on the premise that the skull medium is homogeneous. To find suitable homogeneity that balances computational speed and accuracy, the present work investigates how the focus deviates after phase-aberration compensation with ray tracing using time-reversal theory. The waveforms are synthetized with ray tracing for phase aberration, by which the properties of the skull bone are simplified for refraction calculation as those of either (i) the cortical bone or (ii) the mean of the entire skull bone, and the focusing accuracy is evaluated for each hypothesis. The propagation of ultrasound for transcranial focusing is simulated with the elastic model using the k-space pseudospectral method. Unlike the fluid model, the elastic model does not omit shear waves in the skull bones, and the influence of that omission is investigated, with the fluid model resulting in a focal deflection of 0.5 mm. The focusing deviations are huge when the properties of the skull bone are idealized with ray tracing as those of the mean of the entire skull bone. The focusing accuracy improves when the properties of the skull bone are idealized as those of the cortical bone. The results reveal minimal deviation (8.6, 3.9, and 3.2% in the three Cartesian coordinates) in the focal region and suggest that transcranial focusing deflections are caused mostly by ultrasonic refraction on the surface of the skull bone. A heterogeneous skull bone causes wave bending but minimal focusing deflection. The proposed simplification of a homogeneous skull bone is more accurate for transcranial ultrasonic path estimation and offers promising applications in transcranial ultrasonic focusing and imaging.
format Online
Article
Text
id pubmed-7174677
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-71746772020-04-29 Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing Jiang, Chen Li, Dan Xu, Feng Li, Ying Liu, Chengcheng Ta, Dean Front Neurosci Neuroscience In transcranial penetration, ultrasound undergoes refraction, diffraction, multi-reflection, and mode conversion. These factors lead to phase aberration and waveform distortion, which impede the realization of transcranial ultrasonic imaging and therapy. Ray tracing has been used to correct the phase aberration and is computationally more efficient than traditional full-wave simulation. However, when ray tracing has been used for transcranial investigation, it has generally been on the premise that the skull medium is homogeneous. To find suitable homogeneity that balances computational speed and accuracy, the present work investigates how the focus deviates after phase-aberration compensation with ray tracing using time-reversal theory. The waveforms are synthetized with ray tracing for phase aberration, by which the properties of the skull bone are simplified for refraction calculation as those of either (i) the cortical bone or (ii) the mean of the entire skull bone, and the focusing accuracy is evaluated for each hypothesis. The propagation of ultrasound for transcranial focusing is simulated with the elastic model using the k-space pseudospectral method. Unlike the fluid model, the elastic model does not omit shear waves in the skull bones, and the influence of that omission is investigated, with the fluid model resulting in a focal deflection of 0.5 mm. The focusing deviations are huge when the properties of the skull bone are idealized with ray tracing as those of the mean of the entire skull bone. The focusing accuracy improves when the properties of the skull bone are idealized as those of the cortical bone. The results reveal minimal deviation (8.6, 3.9, and 3.2% in the three Cartesian coordinates) in the focal region and suggest that transcranial focusing deflections are caused mostly by ultrasonic refraction on the surface of the skull bone. A heterogeneous skull bone causes wave bending but minimal focusing deflection. The proposed simplification of a homogeneous skull bone is more accurate for transcranial ultrasonic path estimation and offers promising applications in transcranial ultrasonic focusing and imaging. Frontiers Media S.A. 2020-04-15 /pmc/articles/PMC7174677/ /pubmed/32351351 http://dx.doi.org/10.3389/fnins.2020.00317 Text en Copyright © 2020 Jiang, Li, Xu, Li, Liu and Ta. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Jiang, Chen
Li, Dan
Xu, Feng
Li, Ying
Liu, Chengcheng
Ta, Dean
Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing
title Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing
title_full Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing
title_fullStr Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing
title_full_unstemmed Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing
title_short Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing
title_sort numerical evaluation of the influence of skull heterogeneity on transcranial ultrasonic focusing
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7174677/
https://www.ncbi.nlm.nih.gov/pubmed/32351351
http://dx.doi.org/10.3389/fnins.2020.00317
work_keys_str_mv AT jiangchen numericalevaluationoftheinfluenceofskullheterogeneityontranscranialultrasonicfocusing
AT lidan numericalevaluationoftheinfluenceofskullheterogeneityontranscranialultrasonicfocusing
AT xufeng numericalevaluationoftheinfluenceofskullheterogeneityontranscranialultrasonicfocusing
AT liying numericalevaluationoftheinfluenceofskullheterogeneityontranscranialultrasonicfocusing
AT liuchengcheng numericalevaluationoftheinfluenceofskullheterogeneityontranscranialultrasonicfocusing
AT tadean numericalevaluationoftheinfluenceofskullheterogeneityontranscranialultrasonicfocusing