In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation

BACKGROUND: Drilling is one of the most widely used process in orthopaedic surgical operation and the same drill bit is used a number of times in hospitals. Using the same drill bit a several times may be the cause of osteosynthesis and osteonecrosis. METHODS: In the present work, the effect of repe...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Vishal, Pandey, Pulak M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7175678/
https://www.ncbi.nlm.nih.gov/pubmed/32355608
http://dx.doi.org/10.1186/s40759-017-0019-z
_version_ 1783524879239217152
author Gupta, Vishal
Pandey, Pulak M.
author_facet Gupta, Vishal
Pandey, Pulak M.
author_sort Gupta, Vishal
collection PubMed
description BACKGROUND: Drilling is one of the most widely used process in orthopaedic surgical operation and the same drill bit is used a number of times in hospitals. Using the same drill bit a several times may be the cause of osteosynthesis and osteonecrosis. METHODS: In the present work, the effect of repeated orthopaedic surgical twist drill bit on the tool wear, force, torque, temperature and chip morphology during porcine cortical bone drilling is studied. Results were compared with rotary ultrasonic drilling (RUD) on the same bone using a hollow drill tool coated with diamond grains. A sequence of 200 experiments (100 with each process, RUD and CD) were performed with constant process parameters. RESULTS: Wear area on the drill bit is significantly increased as the drill bit is used repeatedly in CD, whereas no attritious wear was found on the diamond coated grains in RUD. CONCLUSIONS: Comparative results showed that cutting force, torque and temperature increased as a function of tool wear in CD as the same drill bit was used a number of times. No significant variation in the cutting force and torque was observed in RUD as the number of drilled holes increased.
format Online
Article
Text
id pubmed-7175678
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-71756782020-04-28 In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation Gupta, Vishal Pandey, Pulak M. Mech Adv Mater Mod Process Research BACKGROUND: Drilling is one of the most widely used process in orthopaedic surgical operation and the same drill bit is used a number of times in hospitals. Using the same drill bit a several times may be the cause of osteosynthesis and osteonecrosis. METHODS: In the present work, the effect of repeated orthopaedic surgical twist drill bit on the tool wear, force, torque, temperature and chip morphology during porcine cortical bone drilling is studied. Results were compared with rotary ultrasonic drilling (RUD) on the same bone using a hollow drill tool coated with diamond grains. A sequence of 200 experiments (100 with each process, RUD and CD) were performed with constant process parameters. RESULTS: Wear area on the drill bit is significantly increased as the drill bit is used repeatedly in CD, whereas no attritious wear was found on the diamond coated grains in RUD. CONCLUSIONS: Comparative results showed that cutting force, torque and temperature increased as a function of tool wear in CD as the same drill bit was used a number of times. No significant variation in the cutting force and torque was observed in RUD as the number of drilled holes increased. Springer International Publishing 2017-01-25 2017 /pmc/articles/PMC7175678/ /pubmed/32355608 http://dx.doi.org/10.1186/s40759-017-0019-z Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Gupta, Vishal
Pandey, Pulak M.
In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation
title In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation
title_full In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation
title_fullStr In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation
title_full_unstemmed In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation
title_short In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation
title_sort in-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7175678/
https://www.ncbi.nlm.nih.gov/pubmed/32355608
http://dx.doi.org/10.1186/s40759-017-0019-z
work_keys_str_mv AT guptavishal insitutoolwearmonitoringanditseffectsontheperformanceofporcinecorticalbonedrillingacomparativeinvitroinvestigation
AT pandeypulakm insitutoolwearmonitoringanditseffectsontheperformanceofporcinecorticalbonedrillingacomparativeinvitroinvestigation