Cargando…
Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head–Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move
Model-based Roentgen stereophotogrammetric analysis (RSA) using elementary geometrical shape (EGS) models allows migration measurement of implants without the necessity of additional attached implant markers. The aims of this study were: (i) to assess the possibility of measuring potential head–tape...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7178274/ https://www.ncbi.nlm.nih.gov/pubmed/32230788 http://dx.doi.org/10.3390/ma13071543 |
_version_ | 1783525418428530688 |
---|---|
author | Xu, Jing Sonntag, Robert Kretzer, J. Philippe Taylor, Dominic Forst, Raimund Seehaus, Frank |
author_facet | Xu, Jing Sonntag, Robert Kretzer, J. Philippe Taylor, Dominic Forst, Raimund Seehaus, Frank |
author_sort | Xu, Jing |
collection | PubMed |
description | Model-based Roentgen stereophotogrammetric analysis (RSA) using elementary geometrical shape (EGS) models allows migration measurement of implants without the necessity of additional attached implant markers. The aims of this study were: (i) to assess the possibility of measuring potential head–taper movement in THA in vivo using model-based RSA and (ii) to prove the validity of measured head–taper migration data in vitro and in vivo. From a previous RSA study with a 10 years follow-up, retrospectively for n = 45 patients head–taper migration was calculated as the relative migration between femoral ball head and taper of the femoral stem using model-based RSA. A head–taper migration of 0.026 mm/year can be detected with available RSA technology. In vitro validation showed a total migration of 268 ± 11 µm along the taper axis in a similar range to what has been reported using the RSA method. In vivo, a proof for interchangeable applicability of model-based RSA (EGS) and standard marker-based RSA methods was indicated by a significant deviation within the migration result after 12-month follow-up for all translation measurements, which was significantly correlated to the measured head–taper migration (r from 0.40 to 0.67; p < 0.05). The results identified that model-based RSA (EGS) could be used to detect head–taper migration in vivo and the measured movement could be validated in vitro and in vivo as well. Those findings supported the possibility of applying RSA for helping evaluate the head–taper corrosion related failure (trunnionosis). |
format | Online Article Text |
id | pubmed-7178274 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-71782742020-04-28 Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head–Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move Xu, Jing Sonntag, Robert Kretzer, J. Philippe Taylor, Dominic Forst, Raimund Seehaus, Frank Materials (Basel) Article Model-based Roentgen stereophotogrammetric analysis (RSA) using elementary geometrical shape (EGS) models allows migration measurement of implants without the necessity of additional attached implant markers. The aims of this study were: (i) to assess the possibility of measuring potential head–taper movement in THA in vivo using model-based RSA and (ii) to prove the validity of measured head–taper migration data in vitro and in vivo. From a previous RSA study with a 10 years follow-up, retrospectively for n = 45 patients head–taper migration was calculated as the relative migration between femoral ball head and taper of the femoral stem using model-based RSA. A head–taper migration of 0.026 mm/year can be detected with available RSA technology. In vitro validation showed a total migration of 268 ± 11 µm along the taper axis in a similar range to what has been reported using the RSA method. In vivo, a proof for interchangeable applicability of model-based RSA (EGS) and standard marker-based RSA methods was indicated by a significant deviation within the migration result after 12-month follow-up for all translation measurements, which was significantly correlated to the measured head–taper migration (r from 0.40 to 0.67; p < 0.05). The results identified that model-based RSA (EGS) could be used to detect head–taper migration in vivo and the measured movement could be validated in vitro and in vivo as well. Those findings supported the possibility of applying RSA for helping evaluate the head–taper corrosion related failure (trunnionosis). MDPI 2020-03-27 /pmc/articles/PMC7178274/ /pubmed/32230788 http://dx.doi.org/10.3390/ma13071543 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xu, Jing Sonntag, Robert Kretzer, J. Philippe Taylor, Dominic Forst, Raimund Seehaus, Frank Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head–Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move |
title | Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head–Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move |
title_full | Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head–Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move |
title_fullStr | Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head–Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move |
title_full_unstemmed | Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head–Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move |
title_short | Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head–Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move |
title_sort | model-based roentgen stereophotogrammetric analysis to monitor the head–taper junction in total hip arthroplasty in vivo—and they do move |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7178274/ https://www.ncbi.nlm.nih.gov/pubmed/32230788 http://dx.doi.org/10.3390/ma13071543 |
work_keys_str_mv | AT xujing modelbasedroentgenstereophotogrammetricanalysistomonitortheheadtaperjunctionintotalhiparthroplastyinvivoandtheydomove AT sonntagrobert modelbasedroentgenstereophotogrammetricanalysistomonitortheheadtaperjunctionintotalhiparthroplastyinvivoandtheydomove AT kretzerjphilippe modelbasedroentgenstereophotogrammetricanalysistomonitortheheadtaperjunctionintotalhiparthroplastyinvivoandtheydomove AT taylordominic modelbasedroentgenstereophotogrammetricanalysistomonitortheheadtaperjunctionintotalhiparthroplastyinvivoandtheydomove AT forstraimund modelbasedroentgenstereophotogrammetricanalysistomonitortheheadtaperjunctionintotalhiparthroplastyinvivoandtheydomove AT seehausfrank modelbasedroentgenstereophotogrammetricanalysistomonitortheheadtaperjunctionintotalhiparthroplastyinvivoandtheydomove |