Cargando…

Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker

A method, quantitative analysis of multicomponents by single marker (QAMS), was established and fully verified based on high-performance liquid chromatography (HPLC) for simultaneous determination of six chromone indicators of Saposhnikoviae Radix (SR). In the present study, cimifugin (C), 5-O-methy...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jinhua, Chen, Luxiao, Qiu, Junna, Zhang, Yu, Wang, Lu, Jiang, Lijuan, Jiang, Yanyan, Liu, Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7178536/
https://www.ncbi.nlm.nih.gov/pubmed/32351756
http://dx.doi.org/10.1155/2020/7867046
_version_ 1783525477457068032
author Zhang, Jinhua
Chen, Luxiao
Qiu, Junna
Zhang, Yu
Wang, Lu
Jiang, Lijuan
Jiang, Yanyan
Liu, Bin
author_facet Zhang, Jinhua
Chen, Luxiao
Qiu, Junna
Zhang, Yu
Wang, Lu
Jiang, Lijuan
Jiang, Yanyan
Liu, Bin
author_sort Zhang, Jinhua
collection PubMed
description A method, quantitative analysis of multicomponents by single marker (QAMS), was established and fully verified based on high-performance liquid chromatography (HPLC) for simultaneous determination of six chromone indicators of Saposhnikoviae Radix (SR). In the present study, cimifugin (C), 5-O-methylvisamminol (V), hamaudol (H), and their corresponding glycosides, prim-O-glucosylcimifugin (GC), 4′-O-β-D-glucosyl-5-O-methylvisamminol (GV), and sec-O-glucosylhamaudol (GH), were selected as bioactive constituents and indicators for the quality evaluation of SR. GV was chosen as the unique reference standard, and relative correction factors (RCF) between GV and the other five chromones were calculated. The feasibility of QAMS for the analysis of chromones was investigated by comparing with the traditional external standard method (ESM). Furthermore, the method was proven to have accuracy (96.98%–102.50%), repeatability (RSD <3%), stability (RSD <3%), precision (RSD <3%), and desirable linearity (R(2) ≧0.9999). Subsequently, 55 batches of commercial SR from different regions were determined by QAMS, and their contents were analyzed by principal component analysis (PCA), correlation analysis, and hierarchical cluster analysis (HCA), respectively. Based on the results, a more refined quality standard of commercial SR was proposed: SR was qualified when the total contents of six chromones were greater than 3 mg·g(−1). Furthermore, SR could initially be regarded as a superior medicine when it satisfied both conditions at the same time: the total content of GC, C, GV, V, GH, and H was greater than 8 mg·g(−1), and the proportion of the total content of C, V, and H was greater than 10%. This study demonstrated that the quality of SR could be successfully evaluated by the developed QAMS method; meanwhile, valuable information was provided for improving the quality standard of SR.
format Online
Article
Text
id pubmed-7178536
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-71785362020-04-29 Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker Zhang, Jinhua Chen, Luxiao Qiu, Junna Zhang, Yu Wang, Lu Jiang, Lijuan Jiang, Yanyan Liu, Bin J Anal Methods Chem Research Article A method, quantitative analysis of multicomponents by single marker (QAMS), was established and fully verified based on high-performance liquid chromatography (HPLC) for simultaneous determination of six chromone indicators of Saposhnikoviae Radix (SR). In the present study, cimifugin (C), 5-O-methylvisamminol (V), hamaudol (H), and their corresponding glycosides, prim-O-glucosylcimifugin (GC), 4′-O-β-D-glucosyl-5-O-methylvisamminol (GV), and sec-O-glucosylhamaudol (GH), were selected as bioactive constituents and indicators for the quality evaluation of SR. GV was chosen as the unique reference standard, and relative correction factors (RCF) between GV and the other five chromones were calculated. The feasibility of QAMS for the analysis of chromones was investigated by comparing with the traditional external standard method (ESM). Furthermore, the method was proven to have accuracy (96.98%–102.50%), repeatability (RSD <3%), stability (RSD <3%), precision (RSD <3%), and desirable linearity (R(2) ≧0.9999). Subsequently, 55 batches of commercial SR from different regions were determined by QAMS, and their contents were analyzed by principal component analysis (PCA), correlation analysis, and hierarchical cluster analysis (HCA), respectively. Based on the results, a more refined quality standard of commercial SR was proposed: SR was qualified when the total contents of six chromones were greater than 3 mg·g(−1). Furthermore, SR could initially be regarded as a superior medicine when it satisfied both conditions at the same time: the total content of GC, C, GV, V, GH, and H was greater than 8 mg·g(−1), and the proportion of the total content of C, V, and H was greater than 10%. This study demonstrated that the quality of SR could be successfully evaluated by the developed QAMS method; meanwhile, valuable information was provided for improving the quality standard of SR. Hindawi 2020-04-14 /pmc/articles/PMC7178536/ /pubmed/32351756 http://dx.doi.org/10.1155/2020/7867046 Text en Copyright © 2020 Jinhua Zhang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhang, Jinhua
Chen, Luxiao
Qiu, Junna
Zhang, Yu
Wang, Lu
Jiang, Lijuan
Jiang, Yanyan
Liu, Bin
Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker
title Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker
title_full Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker
title_fullStr Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker
title_full_unstemmed Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker
title_short Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker
title_sort simultaneous determination of six chromones in saposhnikoviae radix via quantitative analysis of multicomponents by single marker
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7178536/
https://www.ncbi.nlm.nih.gov/pubmed/32351756
http://dx.doi.org/10.1155/2020/7867046
work_keys_str_mv AT zhangjinhua simultaneousdeterminationofsixchromonesinsaposhnikoviaeradixviaquantitativeanalysisofmulticomponentsbysinglemarker
AT chenluxiao simultaneousdeterminationofsixchromonesinsaposhnikoviaeradixviaquantitativeanalysisofmulticomponentsbysinglemarker
AT qiujunna simultaneousdeterminationofsixchromonesinsaposhnikoviaeradixviaquantitativeanalysisofmulticomponentsbysinglemarker
AT zhangyu simultaneousdeterminationofsixchromonesinsaposhnikoviaeradixviaquantitativeanalysisofmulticomponentsbysinglemarker
AT wanglu simultaneousdeterminationofsixchromonesinsaposhnikoviaeradixviaquantitativeanalysisofmulticomponentsbysinglemarker
AT jianglijuan simultaneousdeterminationofsixchromonesinsaposhnikoviaeradixviaquantitativeanalysisofmulticomponentsbysinglemarker
AT jiangyanyan simultaneousdeterminationofsixchromonesinsaposhnikoviaeradixviaquantitativeanalysisofmulticomponentsbysinglemarker
AT liubin simultaneousdeterminationofsixchromonesinsaposhnikoviaeradixviaquantitativeanalysisofmulticomponentsbysinglemarker