Cargando…
Fundamental Properties and Thermal Transferability of Masonry Built by Autoclaved Aerated Concrete Self-Insulation Blocks
This paper performed a detailed study on the fundamental properties and thermal conductivity of autoclaved aerated concrete (AAC) self-insulation block, and the mechanical properties and heat transfer resistance of the AAC self-insulation block masonry. Different kinds of joints and the plastering s...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7178685/ https://www.ncbi.nlm.nih.gov/pubmed/32260236 http://dx.doi.org/10.3390/ma13071680 |
_version_ | 1783525513465167872 |
---|---|
author | Li, Fenglan Chen, Gonglian Zhang, Yunyun Hao, Yongchang Si, Zhengkai |
author_facet | Li, Fenglan Chen, Gonglian Zhang, Yunyun Hao, Yongchang Si, Zhengkai |
author_sort | Li, Fenglan |
collection | PubMed |
description | This paper performed a detailed study on the fundamental properties and thermal conductivity of autoclaved aerated concrete (AAC) self-insulation block, and the mechanical properties and heat transfer resistance of the AAC self-insulation block masonry. Different kinds of joints and the plastering surface were used to build the masonry specimens. The distinctive feature of the blocks and mortars is the lower thermal conductivity with expected strength. Compared to those with larger thickness of insulation mortar joints, the masonry with thin-layer mortar joints had better compressive performance and lower shear strength. The compressive strength of masonry was related with the block and mortar strengths, the shear strength of masonry along mortar joints was related with the mortar strength. The stress–strain relationship of masonry in compression could be predicted by the similar expression of conventional block masonry. The tested heat transfer coefficient of AAC self-insulation block masonry with thickness of 250 mm without plastering surfaces was (0.558 ± 0.003) W/(m(2)·K). With the plastering surfaces, the heat transfer coefficient reduced by 4.4% to 8.9%. Good agreements in values of heat transfer coefficient existed by using the test, theoretical computation and ANSYS (ANSYS Inc. Canonsburg, PA, USA) analytical methods. Based on the extensibility analyses, the heat transfer coefficients of AAC self-insultation block masonry with different thickness are proposed. The best thickness is proposed for the outer walls of residential buildings in different cold zone to meet the design requirement of energy conservation. |
format | Online Article Text |
id | pubmed-7178685 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-71786852020-04-28 Fundamental Properties and Thermal Transferability of Masonry Built by Autoclaved Aerated Concrete Self-Insulation Blocks Li, Fenglan Chen, Gonglian Zhang, Yunyun Hao, Yongchang Si, Zhengkai Materials (Basel) Article This paper performed a detailed study on the fundamental properties and thermal conductivity of autoclaved aerated concrete (AAC) self-insulation block, and the mechanical properties and heat transfer resistance of the AAC self-insulation block masonry. Different kinds of joints and the plastering surface were used to build the masonry specimens. The distinctive feature of the blocks and mortars is the lower thermal conductivity with expected strength. Compared to those with larger thickness of insulation mortar joints, the masonry with thin-layer mortar joints had better compressive performance and lower shear strength. The compressive strength of masonry was related with the block and mortar strengths, the shear strength of masonry along mortar joints was related with the mortar strength. The stress–strain relationship of masonry in compression could be predicted by the similar expression of conventional block masonry. The tested heat transfer coefficient of AAC self-insulation block masonry with thickness of 250 mm without plastering surfaces was (0.558 ± 0.003) W/(m(2)·K). With the plastering surfaces, the heat transfer coefficient reduced by 4.4% to 8.9%. Good agreements in values of heat transfer coefficient existed by using the test, theoretical computation and ANSYS (ANSYS Inc. Canonsburg, PA, USA) analytical methods. Based on the extensibility analyses, the heat transfer coefficients of AAC self-insultation block masonry with different thickness are proposed. The best thickness is proposed for the outer walls of residential buildings in different cold zone to meet the design requirement of energy conservation. MDPI 2020-04-03 /pmc/articles/PMC7178685/ /pubmed/32260236 http://dx.doi.org/10.3390/ma13071680 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Fenglan Chen, Gonglian Zhang, Yunyun Hao, Yongchang Si, Zhengkai Fundamental Properties and Thermal Transferability of Masonry Built by Autoclaved Aerated Concrete Self-Insulation Blocks |
title | Fundamental Properties and Thermal Transferability of Masonry Built by Autoclaved Aerated Concrete Self-Insulation Blocks |
title_full | Fundamental Properties and Thermal Transferability of Masonry Built by Autoclaved Aerated Concrete Self-Insulation Blocks |
title_fullStr | Fundamental Properties and Thermal Transferability of Masonry Built by Autoclaved Aerated Concrete Self-Insulation Blocks |
title_full_unstemmed | Fundamental Properties and Thermal Transferability of Masonry Built by Autoclaved Aerated Concrete Self-Insulation Blocks |
title_short | Fundamental Properties and Thermal Transferability of Masonry Built by Autoclaved Aerated Concrete Self-Insulation Blocks |
title_sort | fundamental properties and thermal transferability of masonry built by autoclaved aerated concrete self-insulation blocks |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7178685/ https://www.ncbi.nlm.nih.gov/pubmed/32260236 http://dx.doi.org/10.3390/ma13071680 |
work_keys_str_mv | AT lifenglan fundamentalpropertiesandthermaltransferabilityofmasonrybuiltbyautoclavedaeratedconcreteselfinsulationblocks AT chengonglian fundamentalpropertiesandthermaltransferabilityofmasonrybuiltbyautoclavedaeratedconcreteselfinsulationblocks AT zhangyunyun fundamentalpropertiesandthermaltransferabilityofmasonrybuiltbyautoclavedaeratedconcreteselfinsulationblocks AT haoyongchang fundamentalpropertiesandthermaltransferabilityofmasonrybuiltbyautoclavedaeratedconcreteselfinsulationblocks AT sizhengkai fundamentalpropertiesandthermaltransferabilityofmasonrybuiltbyautoclavedaeratedconcreteselfinsulationblocks |