Cargando…
Validity and reliability of State-Trait Anxiety Inventory in Danish women aged 45 years and older with abnormal cervical screening results
BACKGROUND: State Trait Anxiety Inventory (STAI) scale was developed in the 1980’s and has been widely used both in clinical settings and in research. However the Danish version of STAI has not been validated. The aim of this study was to assess the validity and reliability of STAI - state anxiety s...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7178932/ https://www.ncbi.nlm.nih.gov/pubmed/32326886 http://dx.doi.org/10.1186/s12874-020-00982-4 |
_version_ | 1783525566337515520 |
---|---|
author | Gustafson, L. W. Gabel, P. Hammer, A. Lauridsen, H. H. Petersen, L. K. Andersen, B. Bor, P. Larsen, M. B. |
author_facet | Gustafson, L. W. Gabel, P. Hammer, A. Lauridsen, H. H. Petersen, L. K. Andersen, B. Bor, P. Larsen, M. B. |
author_sort | Gustafson, L. W. |
collection | PubMed |
description | BACKGROUND: State Trait Anxiety Inventory (STAI) scale was developed in the 1980’s and has been widely used both in clinical settings and in research. However the Danish version of STAI has not been validated. The aim of this study was to assess the validity and reliability of STAI - state anxiety scale in Danish women aged 45 years and older with abnormal cervical cancer screening results. METHODS: Women ≥45 years referred with an abnormal cervical cytology and healthy volunteers (n = 12) underwent cognitive interview after completing STAI. Further, STAI was sent out in an electronic questionnaire to women (n = 109) seen at the gynecological department with abnormal cervical cancer screening test during 2018. Validity and reliability of STAI was evaluated according to the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist by examining internal consistency, test-retest reliability, measurement error, floor and ceiling, construct validity and content validity. RESULTS: In the cognitive interviews the content validity was evaluated to be very good. The internal consistency of the scale was excellent with Cronbach’s α = 0.93. Test-retest reliability was good with an intra-class correlation coefficient of 0.80 and the systematic difference between test-retest results was negligible. The construct validity was good. CONCLUSION: To our best knowledge, this is the first validation study of the Danish translation of STAI-state anxiety scale. This version of STAI demonstrates an acceptable reliability and validity when used in a gynecological setting. |
format | Online Article Text |
id | pubmed-7178932 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-71789322020-04-26 Validity and reliability of State-Trait Anxiety Inventory in Danish women aged 45 years and older with abnormal cervical screening results Gustafson, L. W. Gabel, P. Hammer, A. Lauridsen, H. H. Petersen, L. K. Andersen, B. Bor, P. Larsen, M. B. BMC Med Res Methodol Research Article BACKGROUND: State Trait Anxiety Inventory (STAI) scale was developed in the 1980’s and has been widely used both in clinical settings and in research. However the Danish version of STAI has not been validated. The aim of this study was to assess the validity and reliability of STAI - state anxiety scale in Danish women aged 45 years and older with abnormal cervical cancer screening results. METHODS: Women ≥45 years referred with an abnormal cervical cytology and healthy volunteers (n = 12) underwent cognitive interview after completing STAI. Further, STAI was sent out in an electronic questionnaire to women (n = 109) seen at the gynecological department with abnormal cervical cancer screening test during 2018. Validity and reliability of STAI was evaluated according to the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist by examining internal consistency, test-retest reliability, measurement error, floor and ceiling, construct validity and content validity. RESULTS: In the cognitive interviews the content validity was evaluated to be very good. The internal consistency of the scale was excellent with Cronbach’s α = 0.93. Test-retest reliability was good with an intra-class correlation coefficient of 0.80 and the systematic difference between test-retest results was negligible. The construct validity was good. CONCLUSION: To our best knowledge, this is the first validation study of the Danish translation of STAI-state anxiety scale. This version of STAI demonstrates an acceptable reliability and validity when used in a gynecological setting. BioMed Central 2020-04-23 /pmc/articles/PMC7178932/ /pubmed/32326886 http://dx.doi.org/10.1186/s12874-020-00982-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Gustafson, L. W. Gabel, P. Hammer, A. Lauridsen, H. H. Petersen, L. K. Andersen, B. Bor, P. Larsen, M. B. Validity and reliability of State-Trait Anxiety Inventory in Danish women aged 45 years and older with abnormal cervical screening results |
title | Validity and reliability of State-Trait Anxiety Inventory in Danish women aged 45 years and older with abnormal cervical screening results |
title_full | Validity and reliability of State-Trait Anxiety Inventory in Danish women aged 45 years and older with abnormal cervical screening results |
title_fullStr | Validity and reliability of State-Trait Anxiety Inventory in Danish women aged 45 years and older with abnormal cervical screening results |
title_full_unstemmed | Validity and reliability of State-Trait Anxiety Inventory in Danish women aged 45 years and older with abnormal cervical screening results |
title_short | Validity and reliability of State-Trait Anxiety Inventory in Danish women aged 45 years and older with abnormal cervical screening results |
title_sort | validity and reliability of state-trait anxiety inventory in danish women aged 45 years and older with abnormal cervical screening results |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7178932/ https://www.ncbi.nlm.nih.gov/pubmed/32326886 http://dx.doi.org/10.1186/s12874-020-00982-4 |
work_keys_str_mv | AT gustafsonlw validityandreliabilityofstatetraitanxietyinventoryindanishwomenaged45yearsandolderwithabnormalcervicalscreeningresults AT gabelp validityandreliabilityofstatetraitanxietyinventoryindanishwomenaged45yearsandolderwithabnormalcervicalscreeningresults AT hammera validityandreliabilityofstatetraitanxietyinventoryindanishwomenaged45yearsandolderwithabnormalcervicalscreeningresults AT lauridsenhh validityandreliabilityofstatetraitanxietyinventoryindanishwomenaged45yearsandolderwithabnormalcervicalscreeningresults AT petersenlk validityandreliabilityofstatetraitanxietyinventoryindanishwomenaged45yearsandolderwithabnormalcervicalscreeningresults AT andersenb validityandreliabilityofstatetraitanxietyinventoryindanishwomenaged45yearsandolderwithabnormalcervicalscreeningresults AT borp validityandreliabilityofstatetraitanxietyinventoryindanishwomenaged45yearsandolderwithabnormalcervicalscreeningresults AT larsenmb validityandreliabilityofstatetraitanxietyinventoryindanishwomenaged45yearsandolderwithabnormalcervicalscreeningresults |