Cargando…

Comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study

BACKGROUND AND AIMS: Tricuspid regurgitation (TR) is a frequent valvular heart disease with relevant adverse impact on patients' prognosis. Adequate TR imaging and evaluation is challenging. In this study, we aimed to compare different imaging modalities (echocardiography and multi‐slice comput...

Descripción completa

Detalles Bibliográficos
Autores principales: Öztürk, Can, Schueler, Robert, Weber, Marcel, Nickenig, Georg, Hammerstingl, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7180046/
https://www.ncbi.nlm.nih.gov/pubmed/32337374
http://dx.doi.org/10.1002/hsr2.159
_version_ 1783525755044495360
author Öztürk, Can
Schueler, Robert
Weber, Marcel
Nickenig, Georg
Hammerstingl, Christoph
author_facet Öztürk, Can
Schueler, Robert
Weber, Marcel
Nickenig, Georg
Hammerstingl, Christoph
author_sort Öztürk, Can
collection PubMed
description BACKGROUND AND AIMS: Tricuspid regurgitation (TR) is a frequent valvular heart disease with relevant adverse impact on patients' prognosis. Adequate TR imaging and evaluation is challenging. In this study, we aimed to compare different imaging modalities (echocardiography and multi‐slice computed tomography) for the assessment of tricuspid valve (TV) function and geometry. METHODS: We retrospectively investigated patients that presented to University Hospital Bonn, Germany, between September 2018 and March 2019, who underwent comprehensive echocardiography and multi‐slice computed tomography (MSCT) to evaluate TR. MSCT was considered the reference approach for dimensional assessment of TV anatomy and echocardiography (transthoracic echocardiography + transesophageal echocardiography) for functional assessment of TV. We used Spearman's Rank order correlation, Bland‐Altman analysis, and intra‐class correlation to compare the different imaging modalities. RESULTS: Forty patients (Mean Age ± SD: 77.5 ± 7.1 years; 35% female) with high grade TR (effective regurgitant orifice area, EROA: 0.49 ± 0.3 cm(2), RegVol: 49.5 ± 13.4 mL) were included. There was a statistically significant but moderate correlation between 2D‐TEE and MSCT for anteroposterior (AP) (r = 0.68, 95% confidence interval [CI]: 0.44‐0.93, P = .05; intraclass correlation [ICC]: 0.77, P = .03) and septolateral (SL) diameters (r = 0.71, 95% CI: 0.33‐0.93, P = .03; ICC = 0.76, P = .05). MSCT and 3D‐TEE showed a strong correlation for determination of TV annulus area (r = 0.94, 95% CI: 0.57‐0.98, P = .002; ICC = 0.95, P = .4), perimeter (r = 0.9, 95% CI: 0.6‐0.98, P = .002; ICC = 0.97, P = .3) and diameters (AP‐Diameter: r = 0.73, 95% CI: 0.06‐0.94, P = .03; ICC = 0.83, P = .09; SL‐Diameter: r = 0.86, 95% CI: 0.47‐0.97, P = .02; ICC = 0.95, P = .1). Only 3D‐TEE allowed for direct measurement of planimetric EROA, which exhibited a significant difference from calculated EROA (0.49 ± 0.4 cm(2), 0.67 ± 0.17 cm(2), P = .05; r = 0.93, 95% CI: 0.5 to 0.99, P = .006). According to Bland‐Altman analysis, we found a relevant agreement between MSCT and 3D‐TEE only for TV area (bias: −1.95, 95% limits of agreement −3.6 to −0.1). CONCLUSION: Only 3D‐TEE allowed for sufficient simultaneous functional and dimensional assessment of TR in our cohort.
format Online
Article
Text
id pubmed-7180046
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-71800462020-04-24 Comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study Öztürk, Can Schueler, Robert Weber, Marcel Nickenig, Georg Hammerstingl, Christoph Health Sci Rep Research Articles BACKGROUND AND AIMS: Tricuspid regurgitation (TR) is a frequent valvular heart disease with relevant adverse impact on patients' prognosis. Adequate TR imaging and evaluation is challenging. In this study, we aimed to compare different imaging modalities (echocardiography and multi‐slice computed tomography) for the assessment of tricuspid valve (TV) function and geometry. METHODS: We retrospectively investigated patients that presented to University Hospital Bonn, Germany, between September 2018 and March 2019, who underwent comprehensive echocardiography and multi‐slice computed tomography (MSCT) to evaluate TR. MSCT was considered the reference approach for dimensional assessment of TV anatomy and echocardiography (transthoracic echocardiography + transesophageal echocardiography) for functional assessment of TV. We used Spearman's Rank order correlation, Bland‐Altman analysis, and intra‐class correlation to compare the different imaging modalities. RESULTS: Forty patients (Mean Age ± SD: 77.5 ± 7.1 years; 35% female) with high grade TR (effective regurgitant orifice area, EROA: 0.49 ± 0.3 cm(2), RegVol: 49.5 ± 13.4 mL) were included. There was a statistically significant but moderate correlation between 2D‐TEE and MSCT for anteroposterior (AP) (r = 0.68, 95% confidence interval [CI]: 0.44‐0.93, P = .05; intraclass correlation [ICC]: 0.77, P = .03) and septolateral (SL) diameters (r = 0.71, 95% CI: 0.33‐0.93, P = .03; ICC = 0.76, P = .05). MSCT and 3D‐TEE showed a strong correlation for determination of TV annulus area (r = 0.94, 95% CI: 0.57‐0.98, P = .002; ICC = 0.95, P = .4), perimeter (r = 0.9, 95% CI: 0.6‐0.98, P = .002; ICC = 0.97, P = .3) and diameters (AP‐Diameter: r = 0.73, 95% CI: 0.06‐0.94, P = .03; ICC = 0.83, P = .09; SL‐Diameter: r = 0.86, 95% CI: 0.47‐0.97, P = .02; ICC = 0.95, P = .1). Only 3D‐TEE allowed for direct measurement of planimetric EROA, which exhibited a significant difference from calculated EROA (0.49 ± 0.4 cm(2), 0.67 ± 0.17 cm(2), P = .05; r = 0.93, 95% CI: 0.5 to 0.99, P = .006). According to Bland‐Altman analysis, we found a relevant agreement between MSCT and 3D‐TEE only for TV area (bias: −1.95, 95% limits of agreement −3.6 to −0.1). CONCLUSION: Only 3D‐TEE allowed for sufficient simultaneous functional and dimensional assessment of TR in our cohort. John Wiley and Sons Inc. 2020-04-23 /pmc/articles/PMC7180046/ /pubmed/32337374 http://dx.doi.org/10.1002/hsr2.159 Text en © 2020 The Authors. Health Science Reports published by Wiley Periodicals LLC This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Articles
Öztürk, Can
Schueler, Robert
Weber, Marcel
Nickenig, Georg
Hammerstingl, Christoph
Comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study
title Comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study
title_full Comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study
title_fullStr Comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study
title_full_unstemmed Comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study
title_short Comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study
title_sort comparison of different imaging modalities for the quantification of tricuspid valve geometry and regurgitation: a retrospective, single‐center study
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7180046/
https://www.ncbi.nlm.nih.gov/pubmed/32337374
http://dx.doi.org/10.1002/hsr2.159
work_keys_str_mv AT ozturkcan comparisonofdifferentimagingmodalitiesforthequantificationoftricuspidvalvegeometryandregurgitationaretrospectivesinglecenterstudy
AT schuelerrobert comparisonofdifferentimagingmodalitiesforthequantificationoftricuspidvalvegeometryandregurgitationaretrospectivesinglecenterstudy
AT webermarcel comparisonofdifferentimagingmodalitiesforthequantificationoftricuspidvalvegeometryandregurgitationaretrospectivesinglecenterstudy
AT nickeniggeorg comparisonofdifferentimagingmodalitiesforthequantificationoftricuspidvalvegeometryandregurgitationaretrospectivesinglecenterstudy
AT hammerstinglchristoph comparisonofdifferentimagingmodalitiesforthequantificationoftricuspidvalvegeometryandregurgitationaretrospectivesinglecenterstudy