Cargando…

Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes

In this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less...

Descripción completa

Detalles Bibliográficos
Autores principales: Rajchowski, Piotr, Stefanski, Jacek, Sadowski, Jaroslaw, Cwalina, Krzysztof K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7180623/
https://www.ncbi.nlm.nih.gov/pubmed/32252269
http://dx.doi.org/10.3390/s20071984
_version_ 1783525861771706368
author Rajchowski, Piotr
Stefanski, Jacek
Sadowski, Jaroslaw
Cwalina, Krzysztof K.
author_facet Rajchowski, Piotr
Stefanski, Jacek
Sadowski, Jaroslaw
Cwalina, Krzysztof K.
author_sort Rajchowski, Piotr
collection PubMed
description In this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations. The presented method allows to continuously provide localization service even in areas with disturbed propagation of the radio signals. Authors performed simulation and measurement studies of the proposed method to verify the precision of position estimation of a moving person in an indoor environment. It is worth noting that to determine the simulation parameters and realize the experimental studies the hybrid localization system demonstrator was developed, combining inertial navigation and radio distance measurements. In the proposed solution, results of distance measurements taken to less than three reference nodes are used to compensate the drift of the position estimated using the inertial sensor. In the obtained simulation and experimental results it was possible to reduce the localization error by nearly 50% regarding the case when only inertial navigation was used, additionally keeping the long term root mean square error at the level of ca. 0.50 m. That gives a degradation of localization precision below 0.1 m with respect to the fusion Kalman filtration when four reference nodes are present.
format Online
Article
Text
id pubmed-7180623
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-71806232020-05-01 Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes Rajchowski, Piotr Stefanski, Jacek Sadowski, Jaroslaw Cwalina, Krzysztof K. Sensors (Basel) Article In this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations. The presented method allows to continuously provide localization service even in areas with disturbed propagation of the radio signals. Authors performed simulation and measurement studies of the proposed method to verify the precision of position estimation of a moving person in an indoor environment. It is worth noting that to determine the simulation parameters and realize the experimental studies the hybrid localization system demonstrator was developed, combining inertial navigation and radio distance measurements. In the proposed solution, results of distance measurements taken to less than three reference nodes are used to compensate the drift of the position estimated using the inertial sensor. In the obtained simulation and experimental results it was possible to reduce the localization error by nearly 50% regarding the case when only inertial navigation was used, additionally keeping the long term root mean square error at the level of ca. 0.50 m. That gives a degradation of localization precision below 0.1 m with respect to the fusion Kalman filtration when four reference nodes are present. MDPI 2020-04-02 /pmc/articles/PMC7180623/ /pubmed/32252269 http://dx.doi.org/10.3390/s20071984 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rajchowski, Piotr
Stefanski, Jacek
Sadowski, Jaroslaw
Cwalina, Krzysztof K.
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
title Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
title_full Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
title_fullStr Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
title_full_unstemmed Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
title_short Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
title_sort person tracking in ultra-wide band hybrid localization system using reduced number of reference nodes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7180623/
https://www.ncbi.nlm.nih.gov/pubmed/32252269
http://dx.doi.org/10.3390/s20071984
work_keys_str_mv AT rajchowskipiotr persontrackinginultrawidebandhybridlocalizationsystemusingreducednumberofreferencenodes
AT stefanskijacek persontrackinginultrawidebandhybridlocalizationsystemusingreducednumberofreferencenodes
AT sadowskijaroslaw persontrackinginultrawidebandhybridlocalizationsystemusingreducednumberofreferencenodes
AT cwalinakrzysztofk persontrackinginultrawidebandhybridlocalizationsystemusingreducednumberofreferencenodes