Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis
The concrete filled pultrusion-GFRP (Glass Fiber Reinforced Polymer) tubular column (CFGC) is popular in hydraulic structures or regions with poor environmental conditions due to its excellent corrosion resistance. Considering the influence of concrete hydration heat, shrinkage, and creep, debonding...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7180894/ https://www.ncbi.nlm.nih.gov/pubmed/32290195 http://dx.doi.org/10.3390/s20072149 |
_version_ | 1783525925332189184 |
---|---|
author | Yang, Wenwei Yang, Xia Li, Shuntao |
author_facet | Yang, Wenwei Yang, Xia Li, Shuntao |
author_sort | Yang, Wenwei |
collection | PubMed |
description | The concrete filled pultrusion-GFRP (Glass Fiber Reinforced Polymer) tubular column (CFGC) is popular in hydraulic structures or regions with poor environmental conditions due to its excellent corrosion resistance. Considering the influence of concrete hydration heat, shrinkage, and creep, debonding may occur in the interface between the GFRP tube and the concrete, which will greatly reduce the cooperation of the GFRP tube and concrete, and will weaken the mechanical property of CFGC. This paper introduces an active monitoring method based on the piezoelectric transducer. In the active sensing approach, the smart aggregate (SA) embedded in the concrete acted as a driver to transmit a modulated stress wave, and the PZT (Lead Zirconate Titanate) patches attached on the outer surface of CFGC serve as sensors to receive signals and transfer them to the computer for saving. Two groups of experiments were designed with the different debonding areas and thicknesses. The artificial damage of CFGC was identified and located by comparing the value of the delay under pulse excitation and the difference of wavelet-based energy under sweep excitation, and the damage indexes were defined based on the wavelet packet energy to quantify the level of the interface damage. The results showed that the debonding damage area of CFGC can be identified effectively through the active monitoring method, and the damage index can accurately reflect the damage level of the interface of GFRP tube and concrete. Therefore, this method can be used to identify and evaluate the interface debonding of CFGC in real time. In addition, if the method can be combined with remote sensing technology, it can be used as a real-time remote sensing monitoring technology to provide a solution for interface health monitoring of CFGC. |
format | Online Article Text |
id | pubmed-7180894 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-71808942020-05-01 Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis Yang, Wenwei Yang, Xia Li, Shuntao Sensors (Basel) Article The concrete filled pultrusion-GFRP (Glass Fiber Reinforced Polymer) tubular column (CFGC) is popular in hydraulic structures or regions with poor environmental conditions due to its excellent corrosion resistance. Considering the influence of concrete hydration heat, shrinkage, and creep, debonding may occur in the interface between the GFRP tube and the concrete, which will greatly reduce the cooperation of the GFRP tube and concrete, and will weaken the mechanical property of CFGC. This paper introduces an active monitoring method based on the piezoelectric transducer. In the active sensing approach, the smart aggregate (SA) embedded in the concrete acted as a driver to transmit a modulated stress wave, and the PZT (Lead Zirconate Titanate) patches attached on the outer surface of CFGC serve as sensors to receive signals and transfer them to the computer for saving. Two groups of experiments were designed with the different debonding areas and thicknesses. The artificial damage of CFGC was identified and located by comparing the value of the delay under pulse excitation and the difference of wavelet-based energy under sweep excitation, and the damage indexes were defined based on the wavelet packet energy to quantify the level of the interface damage. The results showed that the debonding damage area of CFGC can be identified effectively through the active monitoring method, and the damage index can accurately reflect the damage level of the interface of GFRP tube and concrete. Therefore, this method can be used to identify and evaluate the interface debonding of CFGC in real time. In addition, if the method can be combined with remote sensing technology, it can be used as a real-time remote sensing monitoring technology to provide a solution for interface health monitoring of CFGC. MDPI 2020-04-10 /pmc/articles/PMC7180894/ /pubmed/32290195 http://dx.doi.org/10.3390/s20072149 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yang, Wenwei Yang, Xia Li, Shuntao Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis |
title | Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis |
title_full | Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis |
title_fullStr | Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis |
title_full_unstemmed | Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis |
title_short | Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis |
title_sort | monitoring of interfacial debonding of concrete filled pultrusion-gfrp tubular column based on piezoelectric smart aggregate and wavelet analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7180894/ https://www.ncbi.nlm.nih.gov/pubmed/32290195 http://dx.doi.org/10.3390/s20072149 |
work_keys_str_mv | AT yangwenwei monitoringofinterfacialdebondingofconcretefilledpultrusiongfrptubularcolumnbasedonpiezoelectricsmartaggregateandwaveletanalysis AT yangxia monitoringofinterfacialdebondingofconcretefilledpultrusiongfrptubularcolumnbasedonpiezoelectricsmartaggregateandwaveletanalysis AT lishuntao monitoringofinterfacialdebondingofconcretefilledpultrusiongfrptubularcolumnbasedonpiezoelectricsmartaggregateandwaveletanalysis |