Compact Open-Path Sensor for Fast Measurements of CO(2) and H(2)O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method

We report here the development of a compact, open-path CO(2) and H(2)O sensor based on the newly introduced scanned-wavelength modulation spectroscopy with the first harmonic phase angle (scanned-WMS-θ1f) method for high-sensitivity, high temporal resolution, ground-based measurements. The considera...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Xiang, Yuan, Feng, Hu, Mai, Chen, Bin, He, Yabai, Yang, Chenguang, Shi, Lifang, Kan, Ruifeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7181033/
https://www.ncbi.nlm.nih.gov/pubmed/32235470
http://dx.doi.org/10.3390/s20071910
_version_ 1783525959199096832
author Li, Xiang
Yuan, Feng
Hu, Mai
Chen, Bin
He, Yabai
Yang, Chenguang
Shi, Lifang
Kan, Ruifeng
author_facet Li, Xiang
Yuan, Feng
Hu, Mai
Chen, Bin
He, Yabai
Yang, Chenguang
Shi, Lifang
Kan, Ruifeng
author_sort Li, Xiang
collection PubMed
description We report here the development of a compact, open-path CO(2) and H(2)O sensor based on the newly introduced scanned-wavelength modulation spectroscopy with the first harmonic phase angle (scanned-WMS-θ1f) method for high-sensitivity, high temporal resolution, ground-based measurements. The considerable advantage of the sensor, compared with existing commercial ones, lies in its fast response of 500 Hz that makes this instrument ideal for resolving details of high-frequency turbulent motion in exceptionally dynamic coastal regions. The good agreement with a commercial nondispersive infrared analyzer supports the utility and accuracy of the sensor. Allan variance analysis shows that the concentration measurement sensitivities can reach 62 ppb CO(2) in 0.06 s and 0.89 ppm H(2)O vapor in 0.26 s averaging time. Autonomous field operation for 15-day continuous measurements of greenhouse gases (CO(2)/H(2)O) was performed on a shore-based monitoring tower in Daya Bay, demonstrating the sensor’s long-term performance. The capability for high-quality fast turbulent atmospheric gas observations allow the potential for better characterization of oceanographic processes.
format Online
Article
Text
id pubmed-7181033
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-71810332020-04-30 Compact Open-Path Sensor for Fast Measurements of CO(2) and H(2)O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method Li, Xiang Yuan, Feng Hu, Mai Chen, Bin He, Yabai Yang, Chenguang Shi, Lifang Kan, Ruifeng Sensors (Basel) Article We report here the development of a compact, open-path CO(2) and H(2)O sensor based on the newly introduced scanned-wavelength modulation spectroscopy with the first harmonic phase angle (scanned-WMS-θ1f) method for high-sensitivity, high temporal resolution, ground-based measurements. The considerable advantage of the sensor, compared with existing commercial ones, lies in its fast response of 500 Hz that makes this instrument ideal for resolving details of high-frequency turbulent motion in exceptionally dynamic coastal regions. The good agreement with a commercial nondispersive infrared analyzer supports the utility and accuracy of the sensor. Allan variance analysis shows that the concentration measurement sensitivities can reach 62 ppb CO(2) in 0.06 s and 0.89 ppm H(2)O vapor in 0.26 s averaging time. Autonomous field operation for 15-day continuous measurements of greenhouse gases (CO(2)/H(2)O) was performed on a shore-based monitoring tower in Daya Bay, demonstrating the sensor’s long-term performance. The capability for high-quality fast turbulent atmospheric gas observations allow the potential for better characterization of oceanographic processes. MDPI 2020-03-30 /pmc/articles/PMC7181033/ /pubmed/32235470 http://dx.doi.org/10.3390/s20071910 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Xiang
Yuan, Feng
Hu, Mai
Chen, Bin
He, Yabai
Yang, Chenguang
Shi, Lifang
Kan, Ruifeng
Compact Open-Path Sensor for Fast Measurements of CO(2) and H(2)O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method
title Compact Open-Path Sensor for Fast Measurements of CO(2) and H(2)O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method
title_full Compact Open-Path Sensor for Fast Measurements of CO(2) and H(2)O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method
title_fullStr Compact Open-Path Sensor for Fast Measurements of CO(2) and H(2)O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method
title_full_unstemmed Compact Open-Path Sensor for Fast Measurements of CO(2) and H(2)O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method
title_short Compact Open-Path Sensor for Fast Measurements of CO(2) and H(2)O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method
title_sort compact open-path sensor for fast measurements of co(2) and h(2)o using scanned-wavelength modulation spectroscopy with 1f-phase method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7181033/
https://www.ncbi.nlm.nih.gov/pubmed/32235470
http://dx.doi.org/10.3390/s20071910
work_keys_str_mv AT lixiang compactopenpathsensorforfastmeasurementsofco2andh2ousingscannedwavelengthmodulationspectroscopywith1fphasemethod
AT yuanfeng compactopenpathsensorforfastmeasurementsofco2andh2ousingscannedwavelengthmodulationspectroscopywith1fphasemethod
AT humai compactopenpathsensorforfastmeasurementsofco2andh2ousingscannedwavelengthmodulationspectroscopywith1fphasemethod
AT chenbin compactopenpathsensorforfastmeasurementsofco2andh2ousingscannedwavelengthmodulationspectroscopywith1fphasemethod
AT heyabai compactopenpathsensorforfastmeasurementsofco2andh2ousingscannedwavelengthmodulationspectroscopywith1fphasemethod
AT yangchenguang compactopenpathsensorforfastmeasurementsofco2andh2ousingscannedwavelengthmodulationspectroscopywith1fphasemethod
AT shilifang compactopenpathsensorforfastmeasurementsofco2andh2ousingscannedwavelengthmodulationspectroscopywith1fphasemethod
AT kanruifeng compactopenpathsensorforfastmeasurementsofco2andh2ousingscannedwavelengthmodulationspectroscopywith1fphasemethod