Cargando…

Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging

In this study, a photoacoustic microscopy (PAM) system based on a multifocal point (MFP) transducer was fabricated to produce a large depth-of-field tissue image. The customized MFP transducer has seven focal points, distributed along with the transducer’s axis, fabricated by separate spherically-fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, Thanh Phuoc, Nguyen, Van Tu, Mondal, Sudip, Pham, Van Hiep, Vu, Dinh Dat, Kim, Byung-Gak, Oh, Junghwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7181221/
https://www.ncbi.nlm.nih.gov/pubmed/32260296
http://dx.doi.org/10.3390/s20072020
_version_ 1783525999825125376
author Nguyen, Thanh Phuoc
Nguyen, Van Tu
Mondal, Sudip
Pham, Van Hiep
Vu, Dinh Dat
Kim, Byung-Gak
Oh, Junghwan
author_facet Nguyen, Thanh Phuoc
Nguyen, Van Tu
Mondal, Sudip
Pham, Van Hiep
Vu, Dinh Dat
Kim, Byung-Gak
Oh, Junghwan
author_sort Nguyen, Thanh Phuoc
collection PubMed
description In this study, a photoacoustic microscopy (PAM) system based on a multifocal point (MFP) transducer was fabricated to produce a large depth-of-field tissue image. The customized MFP transducer has seven focal points, distributed along with the transducer’s axis, fabricated by separate spherically-focused surfaces. These surfaces generate distinct focal zones that are overlapped to extend the depth-of-field. This design allows extending the focal zone of 10 mm for the 11 MHz MFP transducer, which is a great improvement over the 0.48 mm focal zone of the 11 MHz single focal point (SFP) transducer. The PAM image penetration depths of a chicken-hemoglobin phantom using SFP and MFP transducers were measured as 5 mm and 8 mm, respectively. The significant increase in the PAM image-based penetration depth of the chicken-hemoglobin phantom was a result of using the customized MFP transducer.
format Online
Article
Text
id pubmed-7181221
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-71812212020-04-28 Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging Nguyen, Thanh Phuoc Nguyen, Van Tu Mondal, Sudip Pham, Van Hiep Vu, Dinh Dat Kim, Byung-Gak Oh, Junghwan Sensors (Basel) Article In this study, a photoacoustic microscopy (PAM) system based on a multifocal point (MFP) transducer was fabricated to produce a large depth-of-field tissue image. The customized MFP transducer has seven focal points, distributed along with the transducer’s axis, fabricated by separate spherically-focused surfaces. These surfaces generate distinct focal zones that are overlapped to extend the depth-of-field. This design allows extending the focal zone of 10 mm for the 11 MHz MFP transducer, which is a great improvement over the 0.48 mm focal zone of the 11 MHz single focal point (SFP) transducer. The PAM image penetration depths of a chicken-hemoglobin phantom using SFP and MFP transducers were measured as 5 mm and 8 mm, respectively. The significant increase in the PAM image-based penetration depth of the chicken-hemoglobin phantom was a result of using the customized MFP transducer. MDPI 2020-04-03 /pmc/articles/PMC7181221/ /pubmed/32260296 http://dx.doi.org/10.3390/s20072020 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nguyen, Thanh Phuoc
Nguyen, Van Tu
Mondal, Sudip
Pham, Van Hiep
Vu, Dinh Dat
Kim, Byung-Gak
Oh, Junghwan
Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging
title Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging
title_full Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging
title_fullStr Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging
title_full_unstemmed Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging
title_short Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging
title_sort improved depth-of-field photoacoustic microscopy with a multifocal point transducer for biomedical imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7181221/
https://www.ncbi.nlm.nih.gov/pubmed/32260296
http://dx.doi.org/10.3390/s20072020
work_keys_str_mv AT nguyenthanhphuoc improveddepthoffieldphotoacousticmicroscopywithamultifocalpointtransducerforbiomedicalimaging
AT nguyenvantu improveddepthoffieldphotoacousticmicroscopywithamultifocalpointtransducerforbiomedicalimaging
AT mondalsudip improveddepthoffieldphotoacousticmicroscopywithamultifocalpointtransducerforbiomedicalimaging
AT phamvanhiep improveddepthoffieldphotoacousticmicroscopywithamultifocalpointtransducerforbiomedicalimaging
AT vudinhdat improveddepthoffieldphotoacousticmicroscopywithamultifocalpointtransducerforbiomedicalimaging
AT kimbyunggak improveddepthoffieldphotoacousticmicroscopywithamultifocalpointtransducerforbiomedicalimaging
AT ohjunghwan improveddepthoffieldphotoacousticmicroscopywithamultifocalpointtransducerforbiomedicalimaging