Cargando…

Ideal Oscillation of a Hydrogenated Deformable Rotor in a Gigahertz Rotation–Translation Nanoconverter at Low Temperatures

It was discovered that large-amplitude axial oscillation can occur on a rotor with an internally hydrogenated deformable part (HDP) in a rotation–translation nanoconverter. The dynamic outputs of the system were investigated using molecular dynamics simulations. When an input rotational frequency (1...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Bo, Shi, Jiao, Wang, Jinbao, Shen, Jianhu, Cai, Kun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7181254/
https://www.ncbi.nlm.nih.gov/pubmed/32244648
http://dx.doi.org/10.3390/s20071969
_version_ 1783526007765991424
author Song, Bo
Shi, Jiao
Wang, Jinbao
Shen, Jianhu
Cai, Kun
author_facet Song, Bo
Shi, Jiao
Wang, Jinbao
Shen, Jianhu
Cai, Kun
author_sort Song, Bo
collection PubMed
description It was discovered that large-amplitude axial oscillation can occur on a rotor with an internally hydrogenated deformable part (HDP) in a rotation–translation nanoconverter. The dynamic outputs of the system were investigated using molecular dynamics simulations. When an input rotational frequency (100 GHz > ω > 20 GHz) was applied at one end of the rotor, the HDP deformed under the centrifugal and van der Waals forces, which simultaneously led to the axial translation of the other end of the rotor. Except at too high an input rotational frequency (e.g., >100 GHz), which led to eccentric rotation and even collapse of the system, the present system could generate a periodic axial oscillation with an amplitude above 0.5 nm at a temperature below 50 K. In other ranges of temperature and amplitude, the oscillation dampened quickly due to the drastic thermal vibrations of the atoms. Furthermore, the effects of the hydrogenation scheme and the length of HDP on the equilibrium position, amplitude, and frequency of oscillation were investigated. The conclusions can be applied to the design of an ideal nano-oscillator based on the present rotation–translation converter model.
format Online
Article
Text
id pubmed-7181254
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-71812542020-04-28 Ideal Oscillation of a Hydrogenated Deformable Rotor in a Gigahertz Rotation–Translation Nanoconverter at Low Temperatures Song, Bo Shi, Jiao Wang, Jinbao Shen, Jianhu Cai, Kun Sensors (Basel) Article It was discovered that large-amplitude axial oscillation can occur on a rotor with an internally hydrogenated deformable part (HDP) in a rotation–translation nanoconverter. The dynamic outputs of the system were investigated using molecular dynamics simulations. When an input rotational frequency (100 GHz > ω > 20 GHz) was applied at one end of the rotor, the HDP deformed under the centrifugal and van der Waals forces, which simultaneously led to the axial translation of the other end of the rotor. Except at too high an input rotational frequency (e.g., >100 GHz), which led to eccentric rotation and even collapse of the system, the present system could generate a periodic axial oscillation with an amplitude above 0.5 nm at a temperature below 50 K. In other ranges of temperature and amplitude, the oscillation dampened quickly due to the drastic thermal vibrations of the atoms. Furthermore, the effects of the hydrogenation scheme and the length of HDP on the equilibrium position, amplitude, and frequency of oscillation were investigated. The conclusions can be applied to the design of an ideal nano-oscillator based on the present rotation–translation converter model. MDPI 2020-04-01 /pmc/articles/PMC7181254/ /pubmed/32244648 http://dx.doi.org/10.3390/s20071969 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Song, Bo
Shi, Jiao
Wang, Jinbao
Shen, Jianhu
Cai, Kun
Ideal Oscillation of a Hydrogenated Deformable Rotor in a Gigahertz Rotation–Translation Nanoconverter at Low Temperatures
title Ideal Oscillation of a Hydrogenated Deformable Rotor in a Gigahertz Rotation–Translation Nanoconverter at Low Temperatures
title_full Ideal Oscillation of a Hydrogenated Deformable Rotor in a Gigahertz Rotation–Translation Nanoconverter at Low Temperatures
title_fullStr Ideal Oscillation of a Hydrogenated Deformable Rotor in a Gigahertz Rotation–Translation Nanoconverter at Low Temperatures
title_full_unstemmed Ideal Oscillation of a Hydrogenated Deformable Rotor in a Gigahertz Rotation–Translation Nanoconverter at Low Temperatures
title_short Ideal Oscillation of a Hydrogenated Deformable Rotor in a Gigahertz Rotation–Translation Nanoconverter at Low Temperatures
title_sort ideal oscillation of a hydrogenated deformable rotor in a gigahertz rotation–translation nanoconverter at low temperatures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7181254/
https://www.ncbi.nlm.nih.gov/pubmed/32244648
http://dx.doi.org/10.3390/s20071969
work_keys_str_mv AT songbo idealoscillationofahydrogenateddeformablerotorinagigahertzrotationtranslationnanoconverteratlowtemperatures
AT shijiao idealoscillationofahydrogenateddeformablerotorinagigahertzrotationtranslationnanoconverteratlowtemperatures
AT wangjinbao idealoscillationofahydrogenateddeformablerotorinagigahertzrotationtranslationnanoconverteratlowtemperatures
AT shenjianhu idealoscillationofahydrogenateddeformablerotorinagigahertzrotationtranslationnanoconverteratlowtemperatures
AT caikun idealoscillationofahydrogenateddeformablerotorinagigahertzrotationtranslationnanoconverteratlowtemperatures