Cargando…
In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus
BACKGROUND/AIMS: Esophageal transit scintigraphy (ETS) is a useful tool for evaluating esophageal motility disorders, although conflicting results are seen due to lack of ideal bolus. Semisolid/solid boluses have shown superiority over liquid boluses, and the present study aims to establish the util...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7182328/ https://www.ncbi.nlm.nih.gov/pubmed/32351267 http://dx.doi.org/10.4103/ijnm.IJNM_204_19 |
_version_ | 1783526224700637184 |
---|---|
author | Sood, Ashwani Gambhir, Sanjay Singh, Deepa Kumar, K Utham Parihar, Ashwin Singh Kheruka, Subhash Dube, Veeresh Deswal, Satyawati |
author_facet | Sood, Ashwani Gambhir, Sanjay Singh, Deepa Kumar, K Utham Parihar, Ashwin Singh Kheruka, Subhash Dube, Veeresh Deswal, Satyawati |
author_sort | Sood, Ashwani |
collection | PubMed |
description | BACKGROUND/AIMS: Esophageal transit scintigraphy (ETS) is a useful tool for evaluating esophageal motility disorders, although conflicting results are seen due to lack of ideal bolus. Semisolid/solid boluses have shown superiority over liquid boluses, and the present study aims to establish the utility of in-house-prepared bolus in normal volunteers and its comparison with liquid bolus. MATERIALS AND METHODS: Thirty-three healthy volunteers were selected for ETS with in-house-prepared semisolid bolus jelly containing (99m)Tc-sulfur colloid. Dynamic studies were acquired in anterior projection with single swallow for both supine and sitting positions. T90% esophageal emptying time (EET) was calculated for whole and three equally divided segments of esophagus and also done with liquid bolus on different day. RESULTS: The median value of EET for semisolid bolus for whole esophagus in sitting and supine positions was 11.7 s (interquartile range [IQR]: 8.0–16.7) and 17.7 s (IQR: 12.0–33.0). EET of liquid bolus for whole esophagus in sitting and supine positions was 9.3 s (IQR: 8.0–13.3) and 13.0 s (IQR: 9.7–25.0), respectively. Significantly different EET for whole esophagus and lower one-third esophagus between sitting and supine positions was seen for semisolid (whole esophagus;P = 0.003, lower one-third esophagus; P = 0.025) and liquid boluses (whole esophagus; P = 0.032, lower one-third esophagus; P = 0.016). Comparing EET using semisolid and liquid boluses, only lower one-third esophagus in supine position showed significant difference (P = 0.033). CONCLUSIONS: In-house-prepared semisolid radiolabeled jelly is inexpensive, easy to prepare with good radiolabeling. Condensed dynamic images from semisolid bolus were better, sharper, and reproducible in comparison to liquid bolus without fragmentation. This study standardized semisolid bolus and verified its suitability for clinical use. |
format | Online Article Text |
id | pubmed-7182328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-71823282020-04-29 In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus Sood, Ashwani Gambhir, Sanjay Singh, Deepa Kumar, K Utham Parihar, Ashwin Singh Kheruka, Subhash Dube, Veeresh Deswal, Satyawati Indian J Nucl Med Original Article BACKGROUND/AIMS: Esophageal transit scintigraphy (ETS) is a useful tool for evaluating esophageal motility disorders, although conflicting results are seen due to lack of ideal bolus. Semisolid/solid boluses have shown superiority over liquid boluses, and the present study aims to establish the utility of in-house-prepared bolus in normal volunteers and its comparison with liquid bolus. MATERIALS AND METHODS: Thirty-three healthy volunteers were selected for ETS with in-house-prepared semisolid bolus jelly containing (99m)Tc-sulfur colloid. Dynamic studies were acquired in anterior projection with single swallow for both supine and sitting positions. T90% esophageal emptying time (EET) was calculated for whole and three equally divided segments of esophagus and also done with liquid bolus on different day. RESULTS: The median value of EET for semisolid bolus for whole esophagus in sitting and supine positions was 11.7 s (interquartile range [IQR]: 8.0–16.7) and 17.7 s (IQR: 12.0–33.0). EET of liquid bolus for whole esophagus in sitting and supine positions was 9.3 s (IQR: 8.0–13.3) and 13.0 s (IQR: 9.7–25.0), respectively. Significantly different EET for whole esophagus and lower one-third esophagus between sitting and supine positions was seen for semisolid (whole esophagus;P = 0.003, lower one-third esophagus; P = 0.025) and liquid boluses (whole esophagus; P = 0.032, lower one-third esophagus; P = 0.016). Comparing EET using semisolid and liquid boluses, only lower one-third esophagus in supine position showed significant difference (P = 0.033). CONCLUSIONS: In-house-prepared semisolid radiolabeled jelly is inexpensive, easy to prepare with good radiolabeling. Condensed dynamic images from semisolid bolus were better, sharper, and reproducible in comparison to liquid bolus without fragmentation. This study standardized semisolid bolus and verified its suitability for clinical use. Wolters Kluwer - Medknow 2020 2020-03-12 /pmc/articles/PMC7182328/ /pubmed/32351267 http://dx.doi.org/10.4103/ijnm.IJNM_204_19 Text en Copyright: © 2020 Indian Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Sood, Ashwani Gambhir, Sanjay Singh, Deepa Kumar, K Utham Parihar, Ashwin Singh Kheruka, Subhash Dube, Veeresh Deswal, Satyawati In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus |
title | In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus |
title_full | In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus |
title_fullStr | In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus |
title_full_unstemmed | In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus |
title_short | In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus |
title_sort | in-house-prepared semisolid bolus for esophageal transit scintigraphy in normal volunteers and its comparison with liquid bolus |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7182328/ https://www.ncbi.nlm.nih.gov/pubmed/32351267 http://dx.doi.org/10.4103/ijnm.IJNM_204_19 |
work_keys_str_mv | AT soodashwani inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus AT gambhirsanjay inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus AT singhdeepa inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus AT kumarkutham inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus AT pariharashwinsingh inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus AT kherukasubhash inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus AT dubeveeresh inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus AT deswalsatyawati inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus |