Cargando…

In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus

BACKGROUND/AIMS: Esophageal transit scintigraphy (ETS) is a useful tool for evaluating esophageal motility disorders, although conflicting results are seen due to lack of ideal bolus. Semisolid/solid boluses have shown superiority over liquid boluses, and the present study aims to establish the util...

Descripción completa

Detalles Bibliográficos
Autores principales: Sood, Ashwani, Gambhir, Sanjay, Singh, Deepa, Kumar, K Utham, Parihar, Ashwin Singh, Kheruka, Subhash, Dube, Veeresh, Deswal, Satyawati
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7182328/
https://www.ncbi.nlm.nih.gov/pubmed/32351267
http://dx.doi.org/10.4103/ijnm.IJNM_204_19
_version_ 1783526224700637184
author Sood, Ashwani
Gambhir, Sanjay
Singh, Deepa
Kumar, K Utham
Parihar, Ashwin Singh
Kheruka, Subhash
Dube, Veeresh
Deswal, Satyawati
author_facet Sood, Ashwani
Gambhir, Sanjay
Singh, Deepa
Kumar, K Utham
Parihar, Ashwin Singh
Kheruka, Subhash
Dube, Veeresh
Deswal, Satyawati
author_sort Sood, Ashwani
collection PubMed
description BACKGROUND/AIMS: Esophageal transit scintigraphy (ETS) is a useful tool for evaluating esophageal motility disorders, although conflicting results are seen due to lack of ideal bolus. Semisolid/solid boluses have shown superiority over liquid boluses, and the present study aims to establish the utility of in-house-prepared bolus in normal volunteers and its comparison with liquid bolus. MATERIALS AND METHODS: Thirty-three healthy volunteers were selected for ETS with in-house-prepared semisolid bolus jelly containing (99m)Tc-sulfur colloid. Dynamic studies were acquired in anterior projection with single swallow for both supine and sitting positions. T90% esophageal emptying time (EET) was calculated for whole and three equally divided segments of esophagus and also done with liquid bolus on different day. RESULTS: The median value of EET for semisolid bolus for whole esophagus in sitting and supine positions was 11.7 s (interquartile range [IQR]: 8.0–16.7) and 17.7 s (IQR: 12.0–33.0). EET of liquid bolus for whole esophagus in sitting and supine positions was 9.3 s (IQR: 8.0–13.3) and 13.0 s (IQR: 9.7–25.0), respectively. Significantly different EET for whole esophagus and lower one-third esophagus between sitting and supine positions was seen for semisolid (whole esophagus;P = 0.003, lower one-third esophagus; P = 0.025) and liquid boluses (whole esophagus; P = 0.032, lower one-third esophagus; P = 0.016). Comparing EET using semisolid and liquid boluses, only lower one-third esophagus in supine position showed significant difference (P = 0.033). CONCLUSIONS: In-house-prepared semisolid radiolabeled jelly is inexpensive, easy to prepare with good radiolabeling. Condensed dynamic images from semisolid bolus were better, sharper, and reproducible in comparison to liquid bolus without fragmentation. This study standardized semisolid bolus and verified its suitability for clinical use.
format Online
Article
Text
id pubmed-7182328
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-71823282020-04-29 In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus Sood, Ashwani Gambhir, Sanjay Singh, Deepa Kumar, K Utham Parihar, Ashwin Singh Kheruka, Subhash Dube, Veeresh Deswal, Satyawati Indian J Nucl Med Original Article BACKGROUND/AIMS: Esophageal transit scintigraphy (ETS) is a useful tool for evaluating esophageal motility disorders, although conflicting results are seen due to lack of ideal bolus. Semisolid/solid boluses have shown superiority over liquid boluses, and the present study aims to establish the utility of in-house-prepared bolus in normal volunteers and its comparison with liquid bolus. MATERIALS AND METHODS: Thirty-three healthy volunteers were selected for ETS with in-house-prepared semisolid bolus jelly containing (99m)Tc-sulfur colloid. Dynamic studies were acquired in anterior projection with single swallow for both supine and sitting positions. T90% esophageal emptying time (EET) was calculated for whole and three equally divided segments of esophagus and also done with liquid bolus on different day. RESULTS: The median value of EET for semisolid bolus for whole esophagus in sitting and supine positions was 11.7 s (interquartile range [IQR]: 8.0–16.7) and 17.7 s (IQR: 12.0–33.0). EET of liquid bolus for whole esophagus in sitting and supine positions was 9.3 s (IQR: 8.0–13.3) and 13.0 s (IQR: 9.7–25.0), respectively. Significantly different EET for whole esophagus and lower one-third esophagus between sitting and supine positions was seen for semisolid (whole esophagus;P = 0.003, lower one-third esophagus; P = 0.025) and liquid boluses (whole esophagus; P = 0.032, lower one-third esophagus; P = 0.016). Comparing EET using semisolid and liquid boluses, only lower one-third esophagus in supine position showed significant difference (P = 0.033). CONCLUSIONS: In-house-prepared semisolid radiolabeled jelly is inexpensive, easy to prepare with good radiolabeling. Condensed dynamic images from semisolid bolus were better, sharper, and reproducible in comparison to liquid bolus without fragmentation. This study standardized semisolid bolus and verified its suitability for clinical use. Wolters Kluwer - Medknow 2020 2020-03-12 /pmc/articles/PMC7182328/ /pubmed/32351267 http://dx.doi.org/10.4103/ijnm.IJNM_204_19 Text en Copyright: © 2020 Indian Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sood, Ashwani
Gambhir, Sanjay
Singh, Deepa
Kumar, K Utham
Parihar, Ashwin Singh
Kheruka, Subhash
Dube, Veeresh
Deswal, Satyawati
In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus
title In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus
title_full In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus
title_fullStr In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus
title_full_unstemmed In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus
title_short In-house-Prepared Semisolid Bolus for Esophageal Transit Scintigraphy in Normal Volunteers and its Comparison with Liquid Bolus
title_sort in-house-prepared semisolid bolus for esophageal transit scintigraphy in normal volunteers and its comparison with liquid bolus
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7182328/
https://www.ncbi.nlm.nih.gov/pubmed/32351267
http://dx.doi.org/10.4103/ijnm.IJNM_204_19
work_keys_str_mv AT soodashwani inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus
AT gambhirsanjay inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus
AT singhdeepa inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus
AT kumarkutham inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus
AT pariharashwinsingh inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus
AT kherukasubhash inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus
AT dubeveeresh inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus
AT deswalsatyawati inhousepreparedsemisolidbolusforesophagealtransitscintigraphyinnormalvolunteersanditscomparisonwithliquidbolus