Cargando…

Validity and reliability of the Australian Therapy Outcome Measures – Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry)

BACKGROUND: Valid and reliable outcome measure enable measurement of health care service impact. There are limited valid and reliable outcome measures for use in podiatry practice to measure the impact of treatment. This research aimed to test the face validity of the AusTOMs for Physiotherapy (AusT...

Descripción completa

Detalles Bibliográficos
Autores principales: Williams, Cylie M., Davies, Nina, Kolic, Jessica, Caserta, Antoni, James, Alicia M., Unsworth, Carolyn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7183624/
https://www.ncbi.nlm.nih.gov/pubmed/32334625
http://dx.doi.org/10.1186/s13047-020-00385-0
_version_ 1783526456710660096
author Williams, Cylie M.
Davies, Nina
Kolic, Jessica
Caserta, Antoni
James, Alicia M.
Unsworth, Carolyn
author_facet Williams, Cylie M.
Davies, Nina
Kolic, Jessica
Caserta, Antoni
James, Alicia M.
Unsworth, Carolyn
author_sort Williams, Cylie M.
collection PubMed
description BACKGROUND: Valid and reliable outcome measure enable measurement of health care service impact. There are limited valid and reliable outcome measures for use in podiatry practice to measure the impact of treatment. This research aimed to test the face validity of the AusTOMs for Physiotherapy (AusTOMs-PT), it’s adaptability to podiatry clinical practice and the reliability of its use with podiatrists. METHODS: Stage 1 used a nominal group technique with podiatrists who worked in public and/or private settings. All podiatrists underwent self-directed training in the AusTOMs framework and measures prior to interviews or focus group discussion. Discussion was centred about transferability of the core scales of the AusTOMs-PT and an adjunct measure, AusTOMs for Occupational Therapy (AusTOMs-OT) to podiatry practice. Stage 2 used 10 case studies representative of people who had foot or ankle concerns. Podiatrists were recruited and trained in the use of the relevant AusTOMs-PT scales. Podiatrists individually scored the cases at two timepoints (1 month apart) using the six scales from the AusTOMs-PT deemed by stage 1 as relevant to podiatry. Intra and inter-rater reliability of scales were determined using intraclass correlation coefficients (ICCs). RESULTS: Thirteen podiatrists participated in individual or focus group interviews in Stage 1. Consensus was gained on six of the nine core scales adopted from the AusTOMs-PT. These were 1. Balance and Postural Control, 3. Musculoskeletal Movement Related Functions, 4. Neurological Movement Related Functions, 5. Pain, 7. Sensory Functions, 8. Skin Functions. Each core scale rated the functional domains of Impairment, Activity Limitation, Participation Restriction and Wellbeing/Distress relating to that presentation of goals of the person in the case study. There were 22 podiatrists complete training and scored two rounds of case studies using the six scales in Stage 2. There were 91%(n = 20) participants with an intra-rater ICC > 0.5 (moderate or greater). Each domain had an inter-rater reliability of > 0.9 (excellent) during the first round. CONCLUSIONS: The AusTOMs-PT for use in podiatry may be implemented to record change in impairment, function, participation and wellbeing of people receiving podiatry treatment. Podiatry specific training and mentoring, together with repeated use could be expected to improve intra-reliability.
format Online
Article
Text
id pubmed-7183624
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-71836242020-04-29 Validity and reliability of the Australian Therapy Outcome Measures – Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry) Williams, Cylie M. Davies, Nina Kolic, Jessica Caserta, Antoni James, Alicia M. Unsworth, Carolyn J Foot Ankle Res Research BACKGROUND: Valid and reliable outcome measure enable measurement of health care service impact. There are limited valid and reliable outcome measures for use in podiatry practice to measure the impact of treatment. This research aimed to test the face validity of the AusTOMs for Physiotherapy (AusTOMs-PT), it’s adaptability to podiatry clinical practice and the reliability of its use with podiatrists. METHODS: Stage 1 used a nominal group technique with podiatrists who worked in public and/or private settings. All podiatrists underwent self-directed training in the AusTOMs framework and measures prior to interviews or focus group discussion. Discussion was centred about transferability of the core scales of the AusTOMs-PT and an adjunct measure, AusTOMs for Occupational Therapy (AusTOMs-OT) to podiatry practice. Stage 2 used 10 case studies representative of people who had foot or ankle concerns. Podiatrists were recruited and trained in the use of the relevant AusTOMs-PT scales. Podiatrists individually scored the cases at two timepoints (1 month apart) using the six scales from the AusTOMs-PT deemed by stage 1 as relevant to podiatry. Intra and inter-rater reliability of scales were determined using intraclass correlation coefficients (ICCs). RESULTS: Thirteen podiatrists participated in individual or focus group interviews in Stage 1. Consensus was gained on six of the nine core scales adopted from the AusTOMs-PT. These were 1. Balance and Postural Control, 3. Musculoskeletal Movement Related Functions, 4. Neurological Movement Related Functions, 5. Pain, 7. Sensory Functions, 8. Skin Functions. Each core scale rated the functional domains of Impairment, Activity Limitation, Participation Restriction and Wellbeing/Distress relating to that presentation of goals of the person in the case study. There were 22 podiatrists complete training and scored two rounds of case studies using the six scales in Stage 2. There were 91%(n = 20) participants with an intra-rater ICC > 0.5 (moderate or greater). Each domain had an inter-rater reliability of > 0.9 (excellent) during the first round. CONCLUSIONS: The AusTOMs-PT for use in podiatry may be implemented to record change in impairment, function, participation and wellbeing of people receiving podiatry treatment. Podiatry specific training and mentoring, together with repeated use could be expected to improve intra-reliability. BioMed Central 2020-04-25 /pmc/articles/PMC7183624/ /pubmed/32334625 http://dx.doi.org/10.1186/s13047-020-00385-0 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Williams, Cylie M.
Davies, Nina
Kolic, Jessica
Caserta, Antoni
James, Alicia M.
Unsworth, Carolyn
Validity and reliability of the Australian Therapy Outcome Measures – Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry)
title Validity and reliability of the Australian Therapy Outcome Measures – Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry)
title_full Validity and reliability of the Australian Therapy Outcome Measures – Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry)
title_fullStr Validity and reliability of the Australian Therapy Outcome Measures – Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry)
title_full_unstemmed Validity and reliability of the Australian Therapy Outcome Measures – Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry)
title_short Validity and reliability of the Australian Therapy Outcome Measures – Physiotherapy, for podiatry (AusTOMs-PT for use in podiatry)
title_sort validity and reliability of the australian therapy outcome measures – physiotherapy, for podiatry (austoms-pt for use in podiatry)
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7183624/
https://www.ncbi.nlm.nih.gov/pubmed/32334625
http://dx.doi.org/10.1186/s13047-020-00385-0
work_keys_str_mv AT williamscyliem validityandreliabilityoftheaustraliantherapyoutcomemeasuresphysiotherapyforpodiatryaustomsptforuseinpodiatry
AT daviesnina validityandreliabilityoftheaustraliantherapyoutcomemeasuresphysiotherapyforpodiatryaustomsptforuseinpodiatry
AT kolicjessica validityandreliabilityoftheaustraliantherapyoutcomemeasuresphysiotherapyforpodiatryaustomsptforuseinpodiatry
AT casertaantoni validityandreliabilityoftheaustraliantherapyoutcomemeasuresphysiotherapyforpodiatryaustomsptforuseinpodiatry
AT jamesaliciam validityandreliabilityoftheaustraliantherapyoutcomemeasuresphysiotherapyforpodiatryaustomsptforuseinpodiatry
AT unsworthcarolyn validityandreliabilityoftheaustraliantherapyoutcomemeasuresphysiotherapyforpodiatryaustomsptforuseinpodiatry