Cargando…

The reliability of Anycheck device related to healing abutment diameter

PURPOSE: The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS: Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Dong-Hoon, Shin, Yo-Han, Park, Jin-Hong, Shim, Ji-Suk, Shin, Sang-Wan, Lee, Jeong-Yol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7183851/
https://www.ncbi.nlm.nih.gov/pubmed/32377321
http://dx.doi.org/10.4047/jap.2020.12.2.83
_version_ 1783526504190181376
author Lee, Dong-Hoon
Shin, Yo-Han
Park, Jin-Hong
Shim, Ji-Suk
Shin, Sang-Wan
Lee, Jeong-Yol
author_facet Lee, Dong-Hoon
Shin, Yo-Han
Park, Jin-Hong
Shim, Ji-Suk
Shin, Sang-Wan
Lee, Jeong-Yol
author_sort Lee, Dong-Hoon
collection PubMed
description PURPOSE: The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS: Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS: The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was −0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION: There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values.
format Online
Article
Text
id pubmed-7183851
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-71838512020-05-06 The reliability of Anycheck device related to healing abutment diameter Lee, Dong-Hoon Shin, Yo-Han Park, Jin-Hong Shim, Ji-Suk Shin, Sang-Wan Lee, Jeong-Yol J Adv Prosthodont Original Article PURPOSE: The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS: Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS: The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was −0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION: There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values. The Korean Academy of Prosthodontics 2020-04 2020-04-22 /pmc/articles/PMC7183851/ /pubmed/32377321 http://dx.doi.org/10.4047/jap.2020.12.2.83 Text en © 2020 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Dong-Hoon
Shin, Yo-Han
Park, Jin-Hong
Shim, Ji-Suk
Shin, Sang-Wan
Lee, Jeong-Yol
The reliability of Anycheck device related to healing abutment diameter
title The reliability of Anycheck device related to healing abutment diameter
title_full The reliability of Anycheck device related to healing abutment diameter
title_fullStr The reliability of Anycheck device related to healing abutment diameter
title_full_unstemmed The reliability of Anycheck device related to healing abutment diameter
title_short The reliability of Anycheck device related to healing abutment diameter
title_sort reliability of anycheck device related to healing abutment diameter
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7183851/
https://www.ncbi.nlm.nih.gov/pubmed/32377321
http://dx.doi.org/10.4047/jap.2020.12.2.83
work_keys_str_mv AT leedonghoon thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT shinyohan thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT parkjinhong thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT shimjisuk thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT shinsangwan thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT leejeongyol thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT leedonghoon reliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT shinyohan reliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT parkjinhong reliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT shimjisuk reliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT shinsangwan reliabilityofanycheckdevicerelatedtohealingabutmentdiameter
AT leejeongyol reliabilityofanycheckdevicerelatedtohealingabutmentdiameter