PURPOSE: The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS: Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7183851/ https://www.ncbi.nlm.nih.gov/pubmed/32377321 http://dx.doi.org/10.4047/jap.2020.12.2.83 |
_version_ | 1783526504190181376 |
---|---|
author | Lee, Dong-Hoon Shin, Yo-Han Park, Jin-Hong Shim, Ji-Suk Shin, Sang-Wan Lee, Jeong-Yol |
author_facet | Lee, Dong-Hoon Shin, Yo-Han Park, Jin-Hong Shim, Ji-Suk Shin, Sang-Wan Lee, Jeong-Yol |
author_sort | Lee, Dong-Hoon |
collection | PubMed |
description | PURPOSE: The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS: Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS: The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was −0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION: There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values. |
format | Online Article Text |
id | pubmed-7183851 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-71838512020-05-06 The reliability of Anycheck device related to healing abutment diameter Lee, Dong-Hoon Shin, Yo-Han Park, Jin-Hong Shim, Ji-Suk Shin, Sang-Wan Lee, Jeong-Yol J Adv Prosthodont Original Article PURPOSE: The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS: Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS: The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was −0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION: There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values. The Korean Academy of Prosthodontics 2020-04 2020-04-22 /pmc/articles/PMC7183851/ /pubmed/32377321 http://dx.doi.org/10.4047/jap.2020.12.2.83 Text en © 2020 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Dong-Hoon Shin, Yo-Han Park, Jin-Hong Shim, Ji-Suk Shin, Sang-Wan Lee, Jeong-Yol The reliability of Anycheck device related to healing abutment diameter |
title | The reliability of Anycheck device related to healing abutment diameter |
title_full | The reliability of Anycheck device related to healing abutment diameter |
title_fullStr | The reliability of Anycheck device related to healing abutment diameter |
title_full_unstemmed | The reliability of Anycheck device related to healing abutment diameter |
title_short | The reliability of Anycheck device related to healing abutment diameter |
title_sort | reliability of anycheck device related to healing abutment diameter |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7183851/ https://www.ncbi.nlm.nih.gov/pubmed/32377321 http://dx.doi.org/10.4047/jap.2020.12.2.83 |
work_keys_str_mv | AT leedonghoon thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT shinyohan thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT parkjinhong thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT shimjisuk thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT shinsangwan thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT leejeongyol thereliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT leedonghoon reliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT shinyohan reliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT parkjinhong reliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT shimjisuk reliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT shinsangwan reliabilityofanycheckdevicerelatedtohealingabutmentdiameter AT leejeongyol reliabilityofanycheckdevicerelatedtohealingabutmentdiameter |