Cargando…

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

PURPOSE: The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conven...

Descripción completa

Detalles Bibliográficos
Autores principales: Freifrau von Maltzahn, Nadine, Bernhard, Florian, Kohorst, Philipp
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7183853/
https://www.ncbi.nlm.nih.gov/pubmed/32377323
http://dx.doi.org/10.4047/jap.2020.12.2.100
_version_ 1783526504688254976
author Freifrau von Maltzahn, Nadine
Bernhard, Florian
Kohorst, Philipp
author_facet Freifrau von Maltzahn, Nadine
Bernhard, Florian
Kohorst, Philipp
author_sort Freifrau von Maltzahn, Nadine
collection PubMed
description PURPOSE: The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS: A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS: Mean absolute marginal discrepancy ranged between 20 µm (group_cer_npl for specimens of Ceramill NPL) and 43 µm (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 µm and 28 µm without the oxide layer. The internal gap varied between 33 µm (group_ti_nem for test samples of Tizian NEM) and 75 µm (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 µm and 76 µm without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION: Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.
format Online
Article
Text
id pubmed-7183853
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-71838532020-05-06 Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes Freifrau von Maltzahn, Nadine Bernhard, Florian Kohorst, Philipp J Adv Prosthodont Original Article PURPOSE: The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS: A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS: Mean absolute marginal discrepancy ranged between 20 µm (group_cer_npl for specimens of Ceramill NPL) and 43 µm (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 µm and 28 µm without the oxide layer. The internal gap varied between 33 µm (group_ti_nem for test samples of Tizian NEM) and 75 µm (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 µm and 76 µm without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION: Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work. The Korean Academy of Prosthodontics 2020-04 2020-04-22 /pmc/articles/PMC7183853/ /pubmed/32377323 http://dx.doi.org/10.4047/jap.2020.12.2.100 Text en © 2020 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Freifrau von Maltzahn, Nadine
Bernhard, Florian
Kohorst, Philipp
Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes
title Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes
title_full Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes
title_fullStr Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes
title_full_unstemmed Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes
title_short Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes
title_sort fitting accuracy of ceramic veneered co-cr crowns produced by different manufacturing processes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7183853/
https://www.ncbi.nlm.nih.gov/pubmed/32377323
http://dx.doi.org/10.4047/jap.2020.12.2.100
work_keys_str_mv AT freifrauvonmaltzahnnadine fittingaccuracyofceramicveneeredcocrcrownsproducedbydifferentmanufacturingprocesses
AT bernhardflorian fittingaccuracyofceramicveneeredcocrcrownsproducedbydifferentmanufacturingprocesses
AT kohorstphilipp fittingaccuracyofceramicveneeredcocrcrownsproducedbydifferentmanufacturingprocesses