Cargando…

Development and Validation of a MATLAB Software Program for Decoding the Treatment Errors in Real-time Position Management™ Gating-generated Breathing Trace

INTRODUCTION: The Real-time Position Management™ (RPM) is used as a motion management tool to reduce normal tissue complication. However, no commercial software is available to quantify the “beam-on” errors in RPM-generated breathing traces. This study aimed to develop and validate an in-house-coded...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumawat, Naveen, Shrotriya, Anil Kumar, Heigrujam, Malhotra Singh, Patro, Kartikeswar, Kumar, Satendra, Bansal, Anil Kumar, Munjal, Ram Kishan, Anand, Anil Kumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7185710/
https://www.ncbi.nlm.nih.gov/pubmed/32355431
http://dx.doi.org/10.4103/jmp.JMP_30_19
_version_ 1783526814678777856
author Kumawat, Naveen
Shrotriya, Anil Kumar
Heigrujam, Malhotra Singh
Patro, Kartikeswar
Kumar, Satendra
Bansal, Anil Kumar
Munjal, Ram Kishan
Anand, Anil Kumar
author_facet Kumawat, Naveen
Shrotriya, Anil Kumar
Heigrujam, Malhotra Singh
Patro, Kartikeswar
Kumar, Satendra
Bansal, Anil Kumar
Munjal, Ram Kishan
Anand, Anil Kumar
author_sort Kumawat, Naveen
collection PubMed
description INTRODUCTION: The Real-time Position Management™ (RPM) is used as a motion management tool to reduce normal tissue complication. However, no commercial software is available to quantify the “beam-on” errors in RPM-generated breathing traces. This study aimed to develop and validate an in-house-coded MATLAB program to quantify the “beam-on” errors in the breathing trace. MATERIALS AND METHODS: A graphical user interface (GUI) was developed using MATLAB (Matrix Laboratory Ra2016) software. The GUI was validated using two phantoms (Varian-gated phantom and Brainlab ET gating phantom) with three regular motion profiles. Treatment time delay was calculated using regular sinusoidal motion profile. Ten patient's irregular breathing profiles were also analyzed using this GUI. RESULTS: The beam-on comparison between the recorded reference trace and irradiated trace profile was done in two ways: (1) beam-on time error and (2) beam-on displacement error. These errors were ≤1.5% with no statistical difference for phase- and amplitude-based treatments. The predicated amplitude levels of reference phase-based profiles, and the actual amplitude levels of amplitude-based irradiated profiles were almost equal. The average treatment time delay was 47 ± 0.003 ms. The irregular breathing profile analysis showed that the amplitude-based gating treatment was more accurate than phase based. CONCLUSION: The developed GUI gave the same and acceptable results for all regular profiles. These errors were due to the lag time of the linear accelerator with gating treatment. This program can be used as to quantifying the intrafraction “beam-on” errors in breathing trace with both mode of gating techniques for irregular breathing trace, and in addition, it is capable to convert phase-based gating parameters to amplitude-based gating parameters for treatment.
format Online
Article
Text
id pubmed-7185710
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-71857102020-04-30 Development and Validation of a MATLAB Software Program for Decoding the Treatment Errors in Real-time Position Management™ Gating-generated Breathing Trace Kumawat, Naveen Shrotriya, Anil Kumar Heigrujam, Malhotra Singh Patro, Kartikeswar Kumar, Satendra Bansal, Anil Kumar Munjal, Ram Kishan Anand, Anil Kumar J Med Phys Original Article INTRODUCTION: The Real-time Position Management™ (RPM) is used as a motion management tool to reduce normal tissue complication. However, no commercial software is available to quantify the “beam-on” errors in RPM-generated breathing traces. This study aimed to develop and validate an in-house-coded MATLAB program to quantify the “beam-on” errors in the breathing trace. MATERIALS AND METHODS: A graphical user interface (GUI) was developed using MATLAB (Matrix Laboratory Ra2016) software. The GUI was validated using two phantoms (Varian-gated phantom and Brainlab ET gating phantom) with three regular motion profiles. Treatment time delay was calculated using regular sinusoidal motion profile. Ten patient's irregular breathing profiles were also analyzed using this GUI. RESULTS: The beam-on comparison between the recorded reference trace and irradiated trace profile was done in two ways: (1) beam-on time error and (2) beam-on displacement error. These errors were ≤1.5% with no statistical difference for phase- and amplitude-based treatments. The predicated amplitude levels of reference phase-based profiles, and the actual amplitude levels of amplitude-based irradiated profiles were almost equal. The average treatment time delay was 47 ± 0.003 ms. The irregular breathing profile analysis showed that the amplitude-based gating treatment was more accurate than phase based. CONCLUSION: The developed GUI gave the same and acceptable results for all regular profiles. These errors were due to the lag time of the linear accelerator with gating treatment. This program can be used as to quantifying the intrafraction “beam-on” errors in breathing trace with both mode of gating techniques for irregular breathing trace, and in addition, it is capable to convert phase-based gating parameters to amplitude-based gating parameters for treatment. Wolters Kluwer - Medknow 2020 2020-03-13 /pmc/articles/PMC7185710/ /pubmed/32355431 http://dx.doi.org/10.4103/jmp.JMP_30_19 Text en Copyright: © 2020 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kumawat, Naveen
Shrotriya, Anil Kumar
Heigrujam, Malhotra Singh
Patro, Kartikeswar
Kumar, Satendra
Bansal, Anil Kumar
Munjal, Ram Kishan
Anand, Anil Kumar
Development and Validation of a MATLAB Software Program for Decoding the Treatment Errors in Real-time Position Management™ Gating-generated Breathing Trace
title Development and Validation of a MATLAB Software Program for Decoding the Treatment Errors in Real-time Position Management™ Gating-generated Breathing Trace
title_full Development and Validation of a MATLAB Software Program for Decoding the Treatment Errors in Real-time Position Management™ Gating-generated Breathing Trace
title_fullStr Development and Validation of a MATLAB Software Program for Decoding the Treatment Errors in Real-time Position Management™ Gating-generated Breathing Trace
title_full_unstemmed Development and Validation of a MATLAB Software Program for Decoding the Treatment Errors in Real-time Position Management™ Gating-generated Breathing Trace
title_short Development and Validation of a MATLAB Software Program for Decoding the Treatment Errors in Real-time Position Management™ Gating-generated Breathing Trace
title_sort development and validation of a matlab software program for decoding the treatment errors in real-time position management™ gating-generated breathing trace
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7185710/
https://www.ncbi.nlm.nih.gov/pubmed/32355431
http://dx.doi.org/10.4103/jmp.JMP_30_19
work_keys_str_mv AT kumawatnaveen developmentandvalidationofamatlabsoftwareprogramfordecodingthetreatmenterrorsinrealtimepositionmanagementgatinggeneratedbreathingtrace
AT shrotriyaanilkumar developmentandvalidationofamatlabsoftwareprogramfordecodingthetreatmenterrorsinrealtimepositionmanagementgatinggeneratedbreathingtrace
AT heigrujammalhotrasingh developmentandvalidationofamatlabsoftwareprogramfordecodingthetreatmenterrorsinrealtimepositionmanagementgatinggeneratedbreathingtrace
AT patrokartikeswar developmentandvalidationofamatlabsoftwareprogramfordecodingthetreatmenterrorsinrealtimepositionmanagementgatinggeneratedbreathingtrace
AT kumarsatendra developmentandvalidationofamatlabsoftwareprogramfordecodingthetreatmenterrorsinrealtimepositionmanagementgatinggeneratedbreathingtrace
AT bansalanilkumar developmentandvalidationofamatlabsoftwareprogramfordecodingthetreatmenterrorsinrealtimepositionmanagementgatinggeneratedbreathingtrace
AT munjalramkishan developmentandvalidationofamatlabsoftwareprogramfordecodingthetreatmenterrorsinrealtimepositionmanagementgatinggeneratedbreathingtrace
AT anandanilkumar developmentandvalidationofamatlabsoftwareprogramfordecodingthetreatmenterrorsinrealtimepositionmanagementgatinggeneratedbreathingtrace