Cargando…

Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia

Current designs of leg‐lengthening implants have faced serious failures due to inadequacies in the mechanical design. The failure typically is the result of fatigue induced by a combined loading condition with axial and shear components acting in the tubular body of the implant. One of the reasons l...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanerva, Mikko, Pärnänen, Tuomas, Jokinen, Jarno, Haaja, Juha, Ritvanen, Antti, Schlenzka, Dietrich
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7187242/
https://www.ncbi.nlm.nih.gov/pubmed/31788838
http://dx.doi.org/10.1002/jor.24545
_version_ 1783527133547593728
author Kanerva, Mikko
Pärnänen, Tuomas
Jokinen, Jarno
Haaja, Juha
Ritvanen, Antti
Schlenzka, Dietrich
author_facet Kanerva, Mikko
Pärnänen, Tuomas
Jokinen, Jarno
Haaja, Juha
Ritvanen, Antti
Schlenzka, Dietrich
author_sort Kanerva, Mikko
collection PubMed
description Current designs of leg‐lengthening implants have faced serious failures due to inadequacies in the mechanical design. The failure typically is the result of fatigue induced by a combined loading condition with axial and shear components acting in the tubular body of the implant. One of the reasons leading to the failure is improper verification testing for the design of the fatigue limit. The current test standards for pre‐clinical design phases of nail implants are relatively straightforward and widely accepted yet cannot produce the three‐dimensional stress state representative of the anticipated operation in a patient during the consolidation phase. This work introduces a major improvement toward a method for verifying fatigue life of tubular as well as solid implants under combined torque, axial load, and bending. The report describes a new loading fixture, a calibration method, and compares the qualification results of finite element simulation analyses and experimental measurements during cyclic loading tests. The findings state that the fixture produces controlled multi‐axial loadings to study varied osteotomy locations, quasi‐static strength and fatigue of intramedullary implants at an intermediate, 2 Hz, cycle rate. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 38:984‐995, 2020
format Online
Article
Text
id pubmed-7187242
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-71872422020-04-28 Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia Kanerva, Mikko Pärnänen, Tuomas Jokinen, Jarno Haaja, Juha Ritvanen, Antti Schlenzka, Dietrich J Orthop Res Research Articles Current designs of leg‐lengthening implants have faced serious failures due to inadequacies in the mechanical design. The failure typically is the result of fatigue induced by a combined loading condition with axial and shear components acting in the tubular body of the implant. One of the reasons leading to the failure is improper verification testing for the design of the fatigue limit. The current test standards for pre‐clinical design phases of nail implants are relatively straightforward and widely accepted yet cannot produce the three‐dimensional stress state representative of the anticipated operation in a patient during the consolidation phase. This work introduces a major improvement toward a method for verifying fatigue life of tubular as well as solid implants under combined torque, axial load, and bending. The report describes a new loading fixture, a calibration method, and compares the qualification results of finite element simulation analyses and experimental measurements during cyclic loading tests. The findings state that the fixture produces controlled multi‐axial loadings to study varied osteotomy locations, quasi‐static strength and fatigue of intramedullary implants at an intermediate, 2 Hz, cycle rate. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 38:984‐995, 2020 John Wiley and Sons Inc. 2019-12-10 2020-05 /pmc/articles/PMC7187242/ /pubmed/31788838 http://dx.doi.org/10.1002/jor.24545 Text en © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Kanerva, Mikko
Pärnänen, Tuomas
Jokinen, Jarno
Haaja, Juha
Ritvanen, Antti
Schlenzka, Dietrich
Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia
title Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia
title_full Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia
title_fullStr Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia
title_full_unstemmed Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia
title_short Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia
title_sort multi‐axis fatigue experimentation system of intramedullary implants for femur and tibia
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7187242/
https://www.ncbi.nlm.nih.gov/pubmed/31788838
http://dx.doi.org/10.1002/jor.24545
work_keys_str_mv AT kanervamikko multiaxisfatigueexperimentationsystemofintramedullaryimplantsforfemurandtibia
AT parnanentuomas multiaxisfatigueexperimentationsystemofintramedullaryimplantsforfemurandtibia
AT jokinenjarno multiaxisfatigueexperimentationsystemofintramedullaryimplantsforfemurandtibia
AT haajajuha multiaxisfatigueexperimentationsystemofintramedullaryimplantsforfemurandtibia
AT ritvanenantti multiaxisfatigueexperimentationsystemofintramedullaryimplantsforfemurandtibia
AT schlenzkadietrich multiaxisfatigueexperimentationsystemofintramedullaryimplantsforfemurandtibia