No functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature

BACKGROUND: Surgical reattachment of the tendon is still the gold standard for ruptures of the distal biceps brachii tendon. Several fixation techniques have been described in the literature, with suture anchors being one of the most common fixation techniques. Currently, there is no data available...

Descripción completa

Detalles Bibliográficos
Autores principales: Weißenberger, Manuel, Heinz, Tizian, Rueckl, Kilian, Rudert, Maximilian, Klug, Alexander, Hoffmann, Reinhard, Schmidt-Horlohé, Kay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7187509/
https://www.ncbi.nlm.nih.gov/pubmed/32340623
http://dx.doi.org/10.1186/s12891-020-03304-3
_version_ 1783527190838640640
author Weißenberger, Manuel
Heinz, Tizian
Rueckl, Kilian
Rudert, Maximilian
Klug, Alexander
Hoffmann, Reinhard
Schmidt-Horlohé, Kay
author_facet Weißenberger, Manuel
Heinz, Tizian
Rueckl, Kilian
Rudert, Maximilian
Klug, Alexander
Hoffmann, Reinhard
Schmidt-Horlohé, Kay
author_sort Weißenberger, Manuel
collection PubMed
description BACKGROUND: Surgical reattachment of the tendon is still the gold standard for ruptures of the distal biceps brachii tendon. Several fixation techniques have been described in the literature, with suture anchors being one of the most common fixation techniques. Currently, there is no data available on how many anchors are required for a safe and stable refixation. In this case report clinical data of a patient with non-simultaneous bilateral distal biceps tendon ruptures treated with a different number of suture anchors for each side (one vs. two) are demonstrated. CASE PRESENTATION: A 47-year-old factory worker suffered a rupture of the distal biceps tendon on both arms following two different occasions. The left side was fixed using a single suture anchor, while refixation on the right side was performed with two anchors. The patient was prospectively followed for one year. Functional outcome was assessed using the Andrews Carson Score (ACS), the Oxford Elbow Score (OES), and the Disabilities of Arm, Shoulder and Hand (DASH) Score after six, twelve, 24 and 48 weeks. Furthermore, an isokinetic strength measurement for flexion strength was performed after 24 and 48 weeks. After 48 weeks the patient presented with excellent functional outcome scores and no follow-up complications. During the follow-up period, no differences in the functional scores nor in the isokinetic flexion strength measurement could be detected. Furthermore, no radiological complications (like heterotopic ossifications) could be detected in the postoperative radiographs after one year. CONCLUSIONS: Anatomic reattachment of the distal biceps tendon is a successful operative treatment option for distal biceps tendon ruptures. Suture anchor fixation remains one of the most common techniques, as it allows fast surgery and provides good results with respect to range of motion (ROM) and functional scoring according to the current literature. However, the number of anchors required for a stable fixation remains unclear. As indicated by our presented case, we hypothesize, that there are no significant differences between a one-point or a two-point fixation. In the presented case report, no intraindividual differences between the usage of one versus two suture anchors were evident in the short-term follow-up.
format Online
Article
Text
id pubmed-7187509
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-71875092020-04-30 No functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature Weißenberger, Manuel Heinz, Tizian Rueckl, Kilian Rudert, Maximilian Klug, Alexander Hoffmann, Reinhard Schmidt-Horlohé, Kay BMC Musculoskelet Disord Case Report BACKGROUND: Surgical reattachment of the tendon is still the gold standard for ruptures of the distal biceps brachii tendon. Several fixation techniques have been described in the literature, with suture anchors being one of the most common fixation techniques. Currently, there is no data available on how many anchors are required for a safe and stable refixation. In this case report clinical data of a patient with non-simultaneous bilateral distal biceps tendon ruptures treated with a different number of suture anchors for each side (one vs. two) are demonstrated. CASE PRESENTATION: A 47-year-old factory worker suffered a rupture of the distal biceps tendon on both arms following two different occasions. The left side was fixed using a single suture anchor, while refixation on the right side was performed with two anchors. The patient was prospectively followed for one year. Functional outcome was assessed using the Andrews Carson Score (ACS), the Oxford Elbow Score (OES), and the Disabilities of Arm, Shoulder and Hand (DASH) Score after six, twelve, 24 and 48 weeks. Furthermore, an isokinetic strength measurement for flexion strength was performed after 24 and 48 weeks. After 48 weeks the patient presented with excellent functional outcome scores and no follow-up complications. During the follow-up period, no differences in the functional scores nor in the isokinetic flexion strength measurement could be detected. Furthermore, no radiological complications (like heterotopic ossifications) could be detected in the postoperative radiographs after one year. CONCLUSIONS: Anatomic reattachment of the distal biceps tendon is a successful operative treatment option for distal biceps tendon ruptures. Suture anchor fixation remains one of the most common techniques, as it allows fast surgery and provides good results with respect to range of motion (ROM) and functional scoring according to the current literature. However, the number of anchors required for a stable fixation remains unclear. As indicated by our presented case, we hypothesize, that there are no significant differences between a one-point or a two-point fixation. In the presented case report, no intraindividual differences between the usage of one versus two suture anchors were evident in the short-term follow-up. BioMed Central 2020-04-27 /pmc/articles/PMC7187509/ /pubmed/32340623 http://dx.doi.org/10.1186/s12891-020-03304-3 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Case Report
Weißenberger, Manuel
Heinz, Tizian
Rueckl, Kilian
Rudert, Maximilian
Klug, Alexander
Hoffmann, Reinhard
Schmidt-Horlohé, Kay
No functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature
title No functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature
title_full No functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature
title_fullStr No functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature
title_full_unstemmed No functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature
title_short No functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature
title_sort no functional differences in anatomic reconstruction with one vs. two suture anchors after non-simultaneous bilateral distal biceps brachii tendon rupture: a case report and review of the literature
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7187509/
https://www.ncbi.nlm.nih.gov/pubmed/32340623
http://dx.doi.org/10.1186/s12891-020-03304-3
work_keys_str_mv AT weißenbergermanuel nofunctionaldifferencesinanatomicreconstructionwithonevstwosutureanchorsafternonsimultaneousbilateraldistalbicepsbrachiitendonruptureacasereportandreviewoftheliterature
AT heinztizian nofunctionaldifferencesinanatomicreconstructionwithonevstwosutureanchorsafternonsimultaneousbilateraldistalbicepsbrachiitendonruptureacasereportandreviewoftheliterature
AT ruecklkilian nofunctionaldifferencesinanatomicreconstructionwithonevstwosutureanchorsafternonsimultaneousbilateraldistalbicepsbrachiitendonruptureacasereportandreviewoftheliterature
AT rudertmaximilian nofunctionaldifferencesinanatomicreconstructionwithonevstwosutureanchorsafternonsimultaneousbilateraldistalbicepsbrachiitendonruptureacasereportandreviewoftheliterature
AT klugalexander nofunctionaldifferencesinanatomicreconstructionwithonevstwosutureanchorsafternonsimultaneousbilateraldistalbicepsbrachiitendonruptureacasereportandreviewoftheliterature
AT hoffmannreinhard nofunctionaldifferencesinanatomicreconstructionwithonevstwosutureanchorsafternonsimultaneousbilateraldistalbicepsbrachiitendonruptureacasereportandreviewoftheliterature
AT schmidthorlohekay nofunctionaldifferencesinanatomicreconstructionwithonevstwosutureanchorsafternonsimultaneousbilateraldistalbicepsbrachiitendonruptureacasereportandreviewoftheliterature