Cargando…

Novel Energy Devices in Head and Neck Robotic Surgery – A Narrative Review

The advent of trans-oral robotic surgery (TORS) has facilitated removal of tumors previously deemed unresectable, by providing access to the deep structures of the head and neck. Despite this, the wider dissemination of TORS has been restricted due to issues with line of access, as the da Vinci robo...

Descripción completa

Detalles Bibliográficos
Autores principales: Ross, Talisa, Tolley, Neil S, Awad, Zaid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7187864/
https://www.ncbi.nlm.nih.gov/pubmed/32426397
http://dx.doi.org/10.2147/RSRR.S247455
_version_ 1783527239965474816
author Ross, Talisa
Tolley, Neil S
Awad, Zaid
author_facet Ross, Talisa
Tolley, Neil S
Awad, Zaid
author_sort Ross, Talisa
collection PubMed
description The advent of trans-oral robotic surgery (TORS) has facilitated removal of tumors previously deemed unresectable, by providing access to the deep structures of the head and neck. Despite this, the wider dissemination of TORS has been restricted due to issues with line of access, as the da Vinci robot was never designed with head and neck surgery in mind. Flexible instruments and novel energy delivery devices offer great potential in overcoming some of the existing challenges surrounding TORS. This review aimed to summarize the existing literature surrounding energy delivery in TORS and highlight areas of future innovation. MEDLINE was searched for studies relating to energy delivery in TORS in November 2019. The existing literature surrounding monopolar and bipolar electrocautery, LASER (CO(2), Tm:YAG and blue LASER), Ligasure and Harmonic was reviewed. Additionally, the latest iteration of the da Vinci; the SP, and the FLEX robot were evaluated as novel methods of energy delivery in TORS. Overall, these novel energy devices and robotic systems are predicted to further improve energy delivery to the head and neck. The use of flexible LASER in particular is well substantiated in the literature. This has the potential to achieve treatment de-escalation, based on the excellent outcomes demonstrated for disease-free margins and post-operative morbidity.
format Online
Article
Text
id pubmed-7187864
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-71878642020-05-18 Novel Energy Devices in Head and Neck Robotic Surgery – A Narrative Review Ross, Talisa Tolley, Neil S Awad, Zaid Robot Surg Review The advent of trans-oral robotic surgery (TORS) has facilitated removal of tumors previously deemed unresectable, by providing access to the deep structures of the head and neck. Despite this, the wider dissemination of TORS has been restricted due to issues with line of access, as the da Vinci robot was never designed with head and neck surgery in mind. Flexible instruments and novel energy delivery devices offer great potential in overcoming some of the existing challenges surrounding TORS. This review aimed to summarize the existing literature surrounding energy delivery in TORS and highlight areas of future innovation. MEDLINE was searched for studies relating to energy delivery in TORS in November 2019. The existing literature surrounding monopolar and bipolar electrocautery, LASER (CO(2), Tm:YAG and blue LASER), Ligasure and Harmonic was reviewed. Additionally, the latest iteration of the da Vinci; the SP, and the FLEX robot were evaluated as novel methods of energy delivery in TORS. Overall, these novel energy devices and robotic systems are predicted to further improve energy delivery to the head and neck. The use of flexible LASER in particular is well substantiated in the literature. This has the potential to achieve treatment de-escalation, based on the excellent outcomes demonstrated for disease-free margins and post-operative morbidity. Dove 2020-04-23 /pmc/articles/PMC7187864/ /pubmed/32426397 http://dx.doi.org/10.2147/RSRR.S247455 Text en © 2020 Ross et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Review
Ross, Talisa
Tolley, Neil S
Awad, Zaid
Novel Energy Devices in Head and Neck Robotic Surgery – A Narrative Review
title Novel Energy Devices in Head and Neck Robotic Surgery – A Narrative Review
title_full Novel Energy Devices in Head and Neck Robotic Surgery – A Narrative Review
title_fullStr Novel Energy Devices in Head and Neck Robotic Surgery – A Narrative Review
title_full_unstemmed Novel Energy Devices in Head and Neck Robotic Surgery – A Narrative Review
title_short Novel Energy Devices in Head and Neck Robotic Surgery – A Narrative Review
title_sort novel energy devices in head and neck robotic surgery – a narrative review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7187864/
https://www.ncbi.nlm.nih.gov/pubmed/32426397
http://dx.doi.org/10.2147/RSRR.S247455
work_keys_str_mv AT rosstalisa novelenergydevicesinheadandneckroboticsurgeryanarrativereview
AT tolleyneils novelenergydevicesinheadandneckroboticsurgeryanarrativereview
AT awadzaid novelenergydevicesinheadandneckroboticsurgeryanarrativereview