Cargando…
Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis
Recently, cation exchange chromatography (CEX) using aqueous volatile buffers was directly coupled with mass spectrometry (MS) and applied for intact analysis of therapeutic proteins and antibodies. In our study, chemical modifications responsible for charge variants were identified by CEX-UV-MS for...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7188404/ https://www.ncbi.nlm.nih.gov/pubmed/32292112 http://dx.doi.org/10.1080/19420862.2020.1739825 |
_version_ | 1783527305659809792 |
---|---|
author | Shi, Rachel Liuqing Xiao, Gang Dillon, Thomas M. Ricci, Margaret S. Bondarenko, Pavel V. |
author_facet | Shi, Rachel Liuqing Xiao, Gang Dillon, Thomas M. Ricci, Margaret S. Bondarenko, Pavel V. |
author_sort | Shi, Rachel Liuqing |
collection | PubMed |
description | Recently, cation exchange chromatography (CEX) using aqueous volatile buffers was directly coupled with mass spectrometry (MS) and applied for intact analysis of therapeutic proteins and antibodies. In our study, chemical modifications responsible for charge variants were identified by CEX-UV-MS for a monoclonal antibody (mAb), a bispecific antibody, and an Fc-fusion protein. We also report post-CEX column addition of organic solvent and acid followed by mixing at elevated temperatures, which unfolded proteins, increased ion intensity (sensitivity) and facilitated top-down analysis. mAb stressed by hydrogen peroxide oxidation was used as a model system, which produced additional CEX peaks. The on-line CEX-UV-MS top-down analysis produced gas-phase fragments containing one or two methionine residues. Oxidation of some methionine residues contributed to earlier (acidic), some to later (basic) eluting peaks, while oxidation of other residues did not change CEX elution. The abundance of the oxidized and non-oxidized fragment ions also allowed estimation of the oxidation percentage of different methionine residues in stressed mAb. CEX-UV-MS measurement revealed a new intact antibody proteoform at 5% that eluted as a basic peak and included paired modifications: high-mannose glycosylation and remaining C-terminal lysine residue (M5/M5 + K). This finding was confirmed by peptide mapping and on-column disulfide reduction coupled with reversed-phase liquid chromatography – top-down MS analysis of the collected basic peak. Overall, our results demonstrate the utility of the on-line method in providing site-specific structural information of charge modifications without fraction collection and laborious peptide mapping. |
format | Online Article Text |
id | pubmed-7188404 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-71884042020-05-01 Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis Shi, Rachel Liuqing Xiao, Gang Dillon, Thomas M. Ricci, Margaret S. Bondarenko, Pavel V. MAbs Report Recently, cation exchange chromatography (CEX) using aqueous volatile buffers was directly coupled with mass spectrometry (MS) and applied for intact analysis of therapeutic proteins and antibodies. In our study, chemical modifications responsible for charge variants were identified by CEX-UV-MS for a monoclonal antibody (mAb), a bispecific antibody, and an Fc-fusion protein. We also report post-CEX column addition of organic solvent and acid followed by mixing at elevated temperatures, which unfolded proteins, increased ion intensity (sensitivity) and facilitated top-down analysis. mAb stressed by hydrogen peroxide oxidation was used as a model system, which produced additional CEX peaks. The on-line CEX-UV-MS top-down analysis produced gas-phase fragments containing one or two methionine residues. Oxidation of some methionine residues contributed to earlier (acidic), some to later (basic) eluting peaks, while oxidation of other residues did not change CEX elution. The abundance of the oxidized and non-oxidized fragment ions also allowed estimation of the oxidation percentage of different methionine residues in stressed mAb. CEX-UV-MS measurement revealed a new intact antibody proteoform at 5% that eluted as a basic peak and included paired modifications: high-mannose glycosylation and remaining C-terminal lysine residue (M5/M5 + K). This finding was confirmed by peptide mapping and on-column disulfide reduction coupled with reversed-phase liquid chromatography – top-down MS analysis of the collected basic peak. Overall, our results demonstrate the utility of the on-line method in providing site-specific structural information of charge modifications without fraction collection and laborious peptide mapping. Taylor & Francis 2020-04-15 /pmc/articles/PMC7188404/ /pubmed/32292112 http://dx.doi.org/10.1080/19420862.2020.1739825 Text en © 2020 Amgen. Published with license by Taylor & Francis Group, LLC. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Report Shi, Rachel Liuqing Xiao, Gang Dillon, Thomas M. Ricci, Margaret S. Bondarenko, Pavel V. Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis |
title | Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis |
title_full | Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis |
title_fullStr | Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis |
title_full_unstemmed | Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis |
title_short | Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis |
title_sort | characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis |
topic | Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7188404/ https://www.ncbi.nlm.nih.gov/pubmed/32292112 http://dx.doi.org/10.1080/19420862.2020.1739825 |
work_keys_str_mv | AT shirachelliuqing characterizationoftherapeuticproteinsbycationexchangechromatographymassspectrometryandtopdownanalysis AT xiaogang characterizationoftherapeuticproteinsbycationexchangechromatographymassspectrometryandtopdownanalysis AT dillonthomasm characterizationoftherapeuticproteinsbycationexchangechromatographymassspectrometryandtopdownanalysis AT riccimargarets characterizationoftherapeuticproteinsbycationexchangechromatographymassspectrometryandtopdownanalysis AT bondarenkopavelv characterizationoftherapeuticproteinsbycationexchangechromatographymassspectrometryandtopdownanalysis |