Cargando…
Analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color Doppler M-mode echocardiography
Assessment of intraventricular pressure gradients (IVPG) using color Doppler M-mode echocardiography has gained increasing interest in the evaluation of cardiac function. However, standardized analysis tools for IVPG quantification are missing. We aimed to evaluate the feasibility, the test-retest o...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7188811/ https://www.ncbi.nlm.nih.gov/pubmed/32346030 http://dx.doi.org/10.1038/s41598-020-64059-4 |
_version_ | 1783527373080100864 |
---|---|
author | Hodzic, Amir Bonnefous, Odile Langet, Hélène Hamiche, Walid Chaufourier, Laure Tournoux, Francois Milliez, Paul Normand, Hervé Saloux, Eric |
author_facet | Hodzic, Amir Bonnefous, Odile Langet, Hélène Hamiche, Walid Chaufourier, Laure Tournoux, Francois Milliez, Paul Normand, Hervé Saloux, Eric |
author_sort | Hodzic, Amir |
collection | PubMed |
description | Assessment of intraventricular pressure gradients (IVPG) using color Doppler M-mode echocardiography has gained increasing interest in the evaluation of cardiac function. However, standardized analysis tools for IVPG quantification are missing. We aimed to evaluate the feasibility, the test-retest observer reproducibility, and the inter-system variability of a semi-automated IVPG quantification algorithm. The study included forty healthy volunteers (50% were men). All volunteers were examined using two ultrasound systems, the Philips Epiq 7 and the General Electric Vivid 6. Left ventricular diastolic (DIVPG) and systolic (SIVPG) intraventricular pressure gradients were measured from the spatiotemporal distribution of intraventricular propagation flow velocities using color Doppler M-mode in standard apical views. There was good feasibility for both systolic and diastolic IVPG measurements (82.5% and 85%, respectively). Intra and inter-observer test-retest variability measured with the intraclass correlation coefficient were 0.98 and 0.93 for DIVPG respectively, and 0.95 and 0.89 for SIVPG respectively. The inter-system concordance was weak to moderate with Lin’s concordance correlation coefficient of 0.59 for DIVPG and 0.25 for SIVPG. In conclusion, it is feasible and reproducible to assess systolic and diastolic IVPG using color Doppler M-mode in healthy volunteers. However, the inter-system variability in IVPG analysis needs to be taken into account, especially when using displayed data. |
format | Online Article Text |
id | pubmed-7188811 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-71888112020-05-04 Analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color Doppler M-mode echocardiography Hodzic, Amir Bonnefous, Odile Langet, Hélène Hamiche, Walid Chaufourier, Laure Tournoux, Francois Milliez, Paul Normand, Hervé Saloux, Eric Sci Rep Article Assessment of intraventricular pressure gradients (IVPG) using color Doppler M-mode echocardiography has gained increasing interest in the evaluation of cardiac function. However, standardized analysis tools for IVPG quantification are missing. We aimed to evaluate the feasibility, the test-retest observer reproducibility, and the inter-system variability of a semi-automated IVPG quantification algorithm. The study included forty healthy volunteers (50% were men). All volunteers were examined using two ultrasound systems, the Philips Epiq 7 and the General Electric Vivid 6. Left ventricular diastolic (DIVPG) and systolic (SIVPG) intraventricular pressure gradients were measured from the spatiotemporal distribution of intraventricular propagation flow velocities using color Doppler M-mode in standard apical views. There was good feasibility for both systolic and diastolic IVPG measurements (82.5% and 85%, respectively). Intra and inter-observer test-retest variability measured with the intraclass correlation coefficient were 0.98 and 0.93 for DIVPG respectively, and 0.95 and 0.89 for SIVPG respectively. The inter-system concordance was weak to moderate with Lin’s concordance correlation coefficient of 0.59 for DIVPG and 0.25 for SIVPG. In conclusion, it is feasible and reproducible to assess systolic and diastolic IVPG using color Doppler M-mode in healthy volunteers. However, the inter-system variability in IVPG analysis needs to be taken into account, especially when using displayed data. Nature Publishing Group UK 2020-04-28 /pmc/articles/PMC7188811/ /pubmed/32346030 http://dx.doi.org/10.1038/s41598-020-64059-4 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Hodzic, Amir Bonnefous, Odile Langet, Hélène Hamiche, Walid Chaufourier, Laure Tournoux, Francois Milliez, Paul Normand, Hervé Saloux, Eric Analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color Doppler M-mode echocardiography |
title | Analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color Doppler M-mode echocardiography |
title_full | Analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color Doppler M-mode echocardiography |
title_fullStr | Analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color Doppler M-mode echocardiography |
title_full_unstemmed | Analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color Doppler M-mode echocardiography |
title_short | Analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color Doppler M-mode echocardiography |
title_sort | analysis of inter-system variability of systolic and diastolic intraventricular pressure gradients derived from color doppler m-mode echocardiography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7188811/ https://www.ncbi.nlm.nih.gov/pubmed/32346030 http://dx.doi.org/10.1038/s41598-020-64059-4 |
work_keys_str_mv | AT hodzicamir analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography AT bonnefousodile analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography AT langethelene analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography AT hamichewalid analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography AT chaufourierlaure analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography AT tournouxfrancois analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography AT milliezpaul analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography AT normandherve analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography AT salouxeric analysisofintersystemvariabilityofsystolicanddiastolicintraventricularpressuregradientsderivedfromcolordopplermmodeechocardiography |