Cargando…
Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis
OBJECTIVE: To compare the von Mises stresses of the pedicle screw system and the displacement of injured vertebrae using 3‐D finite element analysis, and to evaluate the curative effect of the pedicle screw system. METHODS: Finite element methods were used for biomechanical comparison of four poster...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons Australia, Ltd
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7189051/ https://www.ncbi.nlm.nih.gov/pubmed/32124568 http://dx.doi.org/10.1111/os.12643 |
_version_ | 1783527427725590528 |
---|---|
author | Wang, Tie‐nan Wu, Bao‐lin Duan, Rui‐meng Yuan, Ya‐shuai Qu, Ming‐jia Zhang, Shuo Huang, Wei Liu, Tao Yu, Xiao‐bing |
author_facet | Wang, Tie‐nan Wu, Bao‐lin Duan, Rui‐meng Yuan, Ya‐shuai Qu, Ming‐jia Zhang, Shuo Huang, Wei Liu, Tao Yu, Xiao‐bing |
author_sort | Wang, Tie‐nan |
collection | PubMed |
description | OBJECTIVE: To compare the von Mises stresses of the pedicle screw system and the displacement of injured vertebrae using 3‐D finite element analysis, and to evaluate the curative effect of the pedicle screw system. METHODS: Finite element methods were used for biomechanical comparison of four posterior short segment pedicle screw fixation techniques. The different pedicle screw models are traditional trajectory (TT), Universal Spine System (USS), cortical bone trajectory (CBT), and CBT at the cranial level and pedicle screw (PS) at the caudal level (UP‐CBT). The stress distribution of the screws and connecting rods under different working conditions and the displacement of the injured vertebrae were compared and analyzed. RESULTS: After the pedicle screw system was fixed, the stress under vertical compression was mainly concentrated at the proximal end of the screw, while the stress was mainly concentrated on the connecting rod during flexion, extension, lateral flexion, and rotation. The TT group had the greatest stress during the flexion, extension, and left and right rotation. The UP‐CBT group was most stressed when the left and right sides were flexed; the stress of the USS screw system was less than that of the other three models during flexion, lateral flexion, and rotation. The maximum von Mises stress values of pedicle screws in all exercise states were 556.2, 340.7, 458.1, and 533.4 MPa, respectively. In the USS group, the displacement of the injured vertebra was small in the flexion, and the left and right lateral flexion and the right rotation were higher than in the TT group and the CBT group. The maximum displacements of the injured vertebrae in all motion states were 1.679, 1.604, 1.752, and 1.777 mm, respectively. CONCLUSION: Universal Spine System pedicle screws are relatively less stressed under different working conditions, the risk of breakage is small, and the model is relatively stable; CBT screws do not exhibit better mechanical properties than conventional pedicle screws and USS pedicle screws. |
format | Online Article Text |
id | pubmed-7189051 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley & Sons Australia, Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-71890512020-04-29 Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis Wang, Tie‐nan Wu, Bao‐lin Duan, Rui‐meng Yuan, Ya‐shuai Qu, Ming‐jia Zhang, Shuo Huang, Wei Liu, Tao Yu, Xiao‐bing Orthop Surg Scientific Articles OBJECTIVE: To compare the von Mises stresses of the pedicle screw system and the displacement of injured vertebrae using 3‐D finite element analysis, and to evaluate the curative effect of the pedicle screw system. METHODS: Finite element methods were used for biomechanical comparison of four posterior short segment pedicle screw fixation techniques. The different pedicle screw models are traditional trajectory (TT), Universal Spine System (USS), cortical bone trajectory (CBT), and CBT at the cranial level and pedicle screw (PS) at the caudal level (UP‐CBT). The stress distribution of the screws and connecting rods under different working conditions and the displacement of the injured vertebrae were compared and analyzed. RESULTS: After the pedicle screw system was fixed, the stress under vertical compression was mainly concentrated at the proximal end of the screw, while the stress was mainly concentrated on the connecting rod during flexion, extension, lateral flexion, and rotation. The TT group had the greatest stress during the flexion, extension, and left and right rotation. The UP‐CBT group was most stressed when the left and right sides were flexed; the stress of the USS screw system was less than that of the other three models during flexion, lateral flexion, and rotation. The maximum von Mises stress values of pedicle screws in all exercise states were 556.2, 340.7, 458.1, and 533.4 MPa, respectively. In the USS group, the displacement of the injured vertebra was small in the flexion, and the left and right lateral flexion and the right rotation were higher than in the TT group and the CBT group. The maximum displacements of the injured vertebrae in all motion states were 1.679, 1.604, 1.752, and 1.777 mm, respectively. CONCLUSION: Universal Spine System pedicle screws are relatively less stressed under different working conditions, the risk of breakage is small, and the model is relatively stable; CBT screws do not exhibit better mechanical properties than conventional pedicle screws and USS pedicle screws. John Wiley & Sons Australia, Ltd 2020-03-02 /pmc/articles/PMC7189051/ /pubmed/32124568 http://dx.doi.org/10.1111/os.12643 Text en © 2020 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Scientific Articles Wang, Tie‐nan Wu, Bao‐lin Duan, Rui‐meng Yuan, Ya‐shuai Qu, Ming‐jia Zhang, Shuo Huang, Wei Liu, Tao Yu, Xiao‐bing Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis |
title | Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis |
title_full | Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis |
title_fullStr | Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis |
title_full_unstemmed | Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis |
title_short | Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis |
title_sort | treatment of thoracolumbar fractures through different short segment pedicle screw fixation techniques: a finite element analysis |
topic | Scientific Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7189051/ https://www.ncbi.nlm.nih.gov/pubmed/32124568 http://dx.doi.org/10.1111/os.12643 |
work_keys_str_mv | AT wangtienan treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis AT wubaolin treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis AT duanruimeng treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis AT yuanyashuai treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis AT qumingjia treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis AT zhangshuo treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis AT huangwei treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis AT liutao treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis AT yuxiaobing treatmentofthoracolumbarfracturesthroughdifferentshortsegmentpediclescrewfixationtechniquesafiniteelementanalysis |