Cargando…
Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study
OBJECTIVE: To evaluate the accuracy of percutaneous pedicle screw (PPS) placement aided by a new drill guide template. METHODS: The patients were divided into guide template group and conventional perspective group. In the conventional perspective group, the screws were placed by hand under fluorosc...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons Australia, Ltd
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7189065/ https://www.ncbi.nlm.nih.gov/pubmed/32133781 http://dx.doi.org/10.1111/os.12642 |
_version_ | 1783527430996099072 |
---|---|
author | Wu, Chao Deng, Jiayan Li, Tao Tan, Lun Yuan, Dechao |
author_facet | Wu, Chao Deng, Jiayan Li, Tao Tan, Lun Yuan, Dechao |
author_sort | Wu, Chao |
collection | PubMed |
description | OBJECTIVE: To evaluate the accuracy of percutaneous pedicle screw (PPS) placement aided by a new drill guide template. METHODS: The patients were divided into guide template group and conventional perspective group. In the conventional perspective group, the screws were placed by hand under fluoroscopy. In the guide template group, the screw placement was aided by a new drill guide template, and the drill guide template is designed according to the patient's ideal pedicle screw, but not based on skin morphology. The accuracy was evaluated by comparing the following parameters between the two groups: pedicle breach level, inclination angle deviation between the left and right screws, sagittal angle deviation between the left and right screws, and position deviation of the left and right screw entry points. The consistency of the postoperative screw angle and the corresponding guide template inclination angle was compared in the guide template group. The operative time, blood loss, and radiation times were compared between the groups. RESULTS: A total of 146 patients (876 screws) were enrolled in our study including 79 (474 screws) in the guide template group and 67 (402 screws) in the conventional perspective group. The pedicle breach level in the guide template group (22/474) was significantly lower than that in the conventional perspective group (47/402) (P < 0.05). The position and direction deviations of the left and right screws in the guide template group (2.06 ± 1.02 mm, 1.23 ± 1.25 mm, 1.83° ± 1.49°) were significantly less than those in the conventional perspective group (5.33 ± 2.99 mm, 4.32 ± 3.25 mm, 2.87° ± 1.56°). The operation time, blood loss, and radiation times were significantly lower in the guide template group (80.49 ± 9.14 min, 50.42 ± 8.9 mL, 11.02 ± 2.44) than those in the conventional perspective group (108.1 ± 21.18 min, 71.7 ± 17.09 mL, 23.53 ± 4.54). There were no significant differences between the postoperative screw angle and the corresponding guide template angle in the guide template group. CONCLUSION: PPS placement aided by a new drill guide template yielded higher screw accuracy and less operative time, blood loss, and radiation exposure than traditional screw placement. |
format | Online Article Text |
id | pubmed-7189065 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley & Sons Australia, Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-71890652020-04-30 Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study Wu, Chao Deng, Jiayan Li, Tao Tan, Lun Yuan, Dechao Orthop Surg Clinical Articles OBJECTIVE: To evaluate the accuracy of percutaneous pedicle screw (PPS) placement aided by a new drill guide template. METHODS: The patients were divided into guide template group and conventional perspective group. In the conventional perspective group, the screws were placed by hand under fluoroscopy. In the guide template group, the screw placement was aided by a new drill guide template, and the drill guide template is designed according to the patient's ideal pedicle screw, but not based on skin morphology. The accuracy was evaluated by comparing the following parameters between the two groups: pedicle breach level, inclination angle deviation between the left and right screws, sagittal angle deviation between the left and right screws, and position deviation of the left and right screw entry points. The consistency of the postoperative screw angle and the corresponding guide template inclination angle was compared in the guide template group. The operative time, blood loss, and radiation times were compared between the groups. RESULTS: A total of 146 patients (876 screws) were enrolled in our study including 79 (474 screws) in the guide template group and 67 (402 screws) in the conventional perspective group. The pedicle breach level in the guide template group (22/474) was significantly lower than that in the conventional perspective group (47/402) (P < 0.05). The position and direction deviations of the left and right screws in the guide template group (2.06 ± 1.02 mm, 1.23 ± 1.25 mm, 1.83° ± 1.49°) were significantly less than those in the conventional perspective group (5.33 ± 2.99 mm, 4.32 ± 3.25 mm, 2.87° ± 1.56°). The operation time, blood loss, and radiation times were significantly lower in the guide template group (80.49 ± 9.14 min, 50.42 ± 8.9 mL, 11.02 ± 2.44) than those in the conventional perspective group (108.1 ± 21.18 min, 71.7 ± 17.09 mL, 23.53 ± 4.54). There were no significant differences between the postoperative screw angle and the corresponding guide template angle in the guide template group. CONCLUSION: PPS placement aided by a new drill guide template yielded higher screw accuracy and less operative time, blood loss, and radiation exposure than traditional screw placement. John Wiley & Sons Australia, Ltd 2020-03-04 /pmc/articles/PMC7189065/ /pubmed/32133781 http://dx.doi.org/10.1111/os.12642 Text en © 2020 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Articles Wu, Chao Deng, Jiayan Li, Tao Tan, Lun Yuan, Dechao Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study |
title | Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study |
title_full | Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study |
title_fullStr | Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study |
title_full_unstemmed | Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study |
title_short | Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study |
title_sort | percutaneous pedicle screw placement aided by a new drill guide template combined with fluoroscopy: an accuracy study |
topic | Clinical Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7189065/ https://www.ncbi.nlm.nih.gov/pubmed/32133781 http://dx.doi.org/10.1111/os.12642 |
work_keys_str_mv | AT wuchao percutaneouspediclescrewplacementaidedbyanewdrillguidetemplatecombinedwithfluoroscopyanaccuracystudy AT dengjiayan percutaneouspediclescrewplacementaidedbyanewdrillguidetemplatecombinedwithfluoroscopyanaccuracystudy AT litao percutaneouspediclescrewplacementaidedbyanewdrillguidetemplatecombinedwithfluoroscopyanaccuracystudy AT tanlun percutaneouspediclescrewplacementaidedbyanewdrillguidetemplatecombinedwithfluoroscopyanaccuracystudy AT yuandechao percutaneouspediclescrewplacementaidedbyanewdrillguidetemplatecombinedwithfluoroscopyanaccuracystudy |