Cargando…
Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging
INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for inoperable, intermediate- or high-risk patients with severe symptomatic aortic stenosis and has been associated with excellent clinical outcomes. A clinically relevant remaining problem is aortic regur...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7190770/ https://www.ncbi.nlm.nih.gov/pubmed/32246266 http://dx.doi.org/10.1007/s12471-020-01414-0 |
_version_ | 1783527753545416704 |
---|---|
author | Kooistra, N. H. M. Abawi, M. Voskuil, M. Urgel, K. Samim, M. Nijhoff, F. Nathoe, H. M. Doevendans, P. A. F. M. Chamuleau, S. A. J. Leenders, G. E. H. Leiner, T. Abrahams, A. C. van der Worp, H. B. Agostoni, P. Stella, P. R. |
author_facet | Kooistra, N. H. M. Abawi, M. Voskuil, M. Urgel, K. Samim, M. Nijhoff, F. Nathoe, H. M. Doevendans, P. A. F. M. Chamuleau, S. A. J. Leenders, G. E. H. Leiner, T. Abrahams, A. C. van der Worp, H. B. Agostoni, P. Stella, P. R. |
author_sort | Kooistra, N. H. M. |
collection | PubMed |
description | INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for inoperable, intermediate- or high-risk patients with severe symptomatic aortic stenosis and has been associated with excellent clinical outcomes. A clinically relevant remaining problem is aortic regurgitation (AR) post-TAVI, which is associated with increased mortality. Therefore, we conducted a prospective randomised trial to assess the safety and efficacy of a first-generation self-expandable valve (SEV; CoreValve) and a third-generation balloon-expandable valve (BEV; Sapien 3) with respect to clinical outcomes and AR as determined quantitatively by magnetic resonance imaging (MRI). METHODS: The ELECT study was an investigator-initiated, single-centre trial involving patients with severe symptomatic aortic stenosis and with a clinical indication for transfemoral TAVI. Fifty-six patients were randomly assigned to the BEV or SEV group. RESULTS: AR determined quantitatively by MRI was lower in the BEV than in the SEV group [regurgitant fraction: 1.1% (0–8.0) vs 8.7% (3.0–14.8) for SEV; p = 0.01]. Secondary endpoints according to the criteria of the Second Valve Academic Research Consortium (VARC-2) showed BEV to have better early safety [0 (0%) vs 8 (30%); p = 0.002] at 30 days and a lower risk of stroke [0 (0%) vs 5 (21%); p = 0.01], major adverse cardiac and cerebrovascular events [0 (0%) vs 10 (38%); p < 0.001] or death [0 (0%) vs 5 (19%); p = 0.02] in the 1st year compared with SEV. CONCLUSIONS: The use of the latest generation of BEV was associated with less AR as quantitatively assessed by MRI. Although the use of MRI to quantify AR is not feasible in daily clinical practice, it should be considered as a surrogate endpoint for clinical outcomes in comparative studies of valves for TAVI. ClinicalTrials.gov number NCT01982032. |
format | Online Article Text |
id | pubmed-7190770 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Bohn Stafleu van Loghum |
record_format | MEDLINE/PubMed |
spelling | pubmed-71907702020-05-04 Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging Kooistra, N. H. M. Abawi, M. Voskuil, M. Urgel, K. Samim, M. Nijhoff, F. Nathoe, H. M. Doevendans, P. A. F. M. Chamuleau, S. A. J. Leenders, G. E. H. Leiner, T. Abrahams, A. C. van der Worp, H. B. Agostoni, P. Stella, P. R. Neth Heart J Original Article INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for inoperable, intermediate- or high-risk patients with severe symptomatic aortic stenosis and has been associated with excellent clinical outcomes. A clinically relevant remaining problem is aortic regurgitation (AR) post-TAVI, which is associated with increased mortality. Therefore, we conducted a prospective randomised trial to assess the safety and efficacy of a first-generation self-expandable valve (SEV; CoreValve) and a third-generation balloon-expandable valve (BEV; Sapien 3) with respect to clinical outcomes and AR as determined quantitatively by magnetic resonance imaging (MRI). METHODS: The ELECT study was an investigator-initiated, single-centre trial involving patients with severe symptomatic aortic stenosis and with a clinical indication for transfemoral TAVI. Fifty-six patients were randomly assigned to the BEV or SEV group. RESULTS: AR determined quantitatively by MRI was lower in the BEV than in the SEV group [regurgitant fraction: 1.1% (0–8.0) vs 8.7% (3.0–14.8) for SEV; p = 0.01]. Secondary endpoints according to the criteria of the Second Valve Academic Research Consortium (VARC-2) showed BEV to have better early safety [0 (0%) vs 8 (30%); p = 0.002] at 30 days and a lower risk of stroke [0 (0%) vs 5 (21%); p = 0.01], major adverse cardiac and cerebrovascular events [0 (0%) vs 10 (38%); p < 0.001] or death [0 (0%) vs 5 (19%); p = 0.02] in the 1st year compared with SEV. CONCLUSIONS: The use of the latest generation of BEV was associated with less AR as quantitatively assessed by MRI. Although the use of MRI to quantify AR is not feasible in daily clinical practice, it should be considered as a surrogate endpoint for clinical outcomes in comparative studies of valves for TAVI. ClinicalTrials.gov number NCT01982032. Bohn Stafleu van Loghum 2020-04-03 2020-05 /pmc/articles/PMC7190770/ /pubmed/32246266 http://dx.doi.org/10.1007/s12471-020-01414-0 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Original Article Kooistra, N. H. M. Abawi, M. Voskuil, M. Urgel, K. Samim, M. Nijhoff, F. Nathoe, H. M. Doevendans, P. A. F. M. Chamuleau, S. A. J. Leenders, G. E. H. Leiner, T. Abrahams, A. C. van der Worp, H. B. Agostoni, P. Stella, P. R. Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging |
title | Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging |
title_full | Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging |
title_fullStr | Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging |
title_full_unstemmed | Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging |
title_short | Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging |
title_sort | randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7190770/ https://www.ncbi.nlm.nih.gov/pubmed/32246266 http://dx.doi.org/10.1007/s12471-020-01414-0 |
work_keys_str_mv | AT kooistranhm randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT abawim randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT voskuilm randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT urgelk randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT samimm randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT nijhofff randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT nathoehm randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT doevendanspafm randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT chamuleausaj randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT leendersgeh randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT leinert randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT abrahamsac randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT vanderworphb randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT agostonip randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging AT stellapr randomisedcomparisonofaballoonexpandableandselfexpandablevalvewithquantitativeassessmentofaorticregurgitationusingmagneticresonanceimaging |