Cargando…

An Alarming Change: What Caused an Instance of Inappropriate Detection in a Wearable Cardioverter-defibrillator?

We describe the case of a patient who received cardiac resynchronization pacemaker therapy (CRT-P) incorporating bridge protection via a wearable cardioverter-defibrillator (WCD) while awaiting final evaluation for permanent placement of an implantable CRT device with defibrillation capabilities. In...

Descripción completa

Detalles Bibliográficos
Autores principales: Tobb, Kardie, Corbisiero, Raffaele, Fish, Frank, Kazemian, Pedram, Muller, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7192131/
https://www.ncbi.nlm.nih.gov/pubmed/32368370
http://dx.doi.org/10.19102/icrm.2020.110201
_version_ 1783527968375570432
author Tobb, Kardie
Corbisiero, Raffaele
Fish, Frank
Kazemian, Pedram
Muller, David
author_facet Tobb, Kardie
Corbisiero, Raffaele
Fish, Frank
Kazemian, Pedram
Muller, David
author_sort Tobb, Kardie
collection PubMed
description We describe the case of a patient who received cardiac resynchronization pacemaker therapy (CRT-P) incorporating bridge protection via a wearable cardioverter-defibrillator (WCD) while awaiting final evaluation for permanent placement of an implantable CRT device with defibrillation capabilities. In an attempt to mitigate symptoms of heart failure, reprogramming of the CRT-P with a V–V offset caused an unusual interaction and alarm from the WCD. This case highlights a unique interaction not previously reported and is clinically relevant to patients awaiting final evaluation for implantable defibrillator system placement.
format Online
Article
Text
id pubmed-7192131
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MediaSphere Medical
record_format MEDLINE/PubMed
spelling pubmed-71921312020-05-04 An Alarming Change: What Caused an Instance of Inappropriate Detection in a Wearable Cardioverter-defibrillator? Tobb, Kardie Corbisiero, Raffaele Fish, Frank Kazemian, Pedram Muller, David J Innov Card Rhythm Manag Case Report We describe the case of a patient who received cardiac resynchronization pacemaker therapy (CRT-P) incorporating bridge protection via a wearable cardioverter-defibrillator (WCD) while awaiting final evaluation for permanent placement of an implantable CRT device with defibrillation capabilities. In an attempt to mitigate symptoms of heart failure, reprogramming of the CRT-P with a V–V offset caused an unusual interaction and alarm from the WCD. This case highlights a unique interaction not previously reported and is clinically relevant to patients awaiting final evaluation for implantable defibrillator system placement. MediaSphere Medical 2020-02-15 /pmc/articles/PMC7192131/ /pubmed/32368370 http://dx.doi.org/10.19102/icrm.2020.110201 Text en Copyright: © 2020 Innovations in Cardiac Rhythm Management http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Tobb, Kardie
Corbisiero, Raffaele
Fish, Frank
Kazemian, Pedram
Muller, David
An Alarming Change: What Caused an Instance of Inappropriate Detection in a Wearable Cardioverter-defibrillator?
title An Alarming Change: What Caused an Instance of Inappropriate Detection in a Wearable Cardioverter-defibrillator?
title_full An Alarming Change: What Caused an Instance of Inappropriate Detection in a Wearable Cardioverter-defibrillator?
title_fullStr An Alarming Change: What Caused an Instance of Inappropriate Detection in a Wearable Cardioverter-defibrillator?
title_full_unstemmed An Alarming Change: What Caused an Instance of Inappropriate Detection in a Wearable Cardioverter-defibrillator?
title_short An Alarming Change: What Caused an Instance of Inappropriate Detection in a Wearable Cardioverter-defibrillator?
title_sort alarming change: what caused an instance of inappropriate detection in a wearable cardioverter-defibrillator?
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7192131/
https://www.ncbi.nlm.nih.gov/pubmed/32368370
http://dx.doi.org/10.19102/icrm.2020.110201
work_keys_str_mv AT tobbkardie analarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT corbisieroraffaele analarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT fishfrank analarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT kazemianpedram analarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT mullerdavid analarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT tobbkardie alarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT corbisieroraffaele alarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT fishfrank alarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT kazemianpedram alarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator
AT mullerdavid alarmingchangewhatcausedaninstanceofinappropriatedetectioninawearablecardioverterdefibrillator