Time-dependent changes in FT4 and FT3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism

BACKGROUND: Thyrotoxicosis is common disorder among endocrine dysfunctions. It is not rare that the free thyroid hormone level exceeds the measurement range of immunoassay. Such extreme high concentration of free thyroid hormone is generally considered to be impossible to measure correctly because o...

Descripción completa

Detalles Bibliográficos
Autores principales: Ito, Yuko, Suzuki, Satoru, Matsumoto, Yoshiko, Ohkouchi, Chiyo, Suzuki, Satoshi, Iwadate, Manabu, Midorikawa, Sanae, Yokoya, Susumu, Suzuki, Shinichi, Shimura, Hiroki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7193347/
https://www.ncbi.nlm.nih.gov/pubmed/32377234
http://dx.doi.org/10.1186/s13044-020-00078-7
_version_ 1783528179701383168
author Ito, Yuko
Suzuki, Satoru
Matsumoto, Yoshiko
Ohkouchi, Chiyo
Suzuki, Satoshi
Iwadate, Manabu
Midorikawa, Sanae
Yokoya, Susumu
Suzuki, Shinichi
Shimura, Hiroki
author_facet Ito, Yuko
Suzuki, Satoru
Matsumoto, Yoshiko
Ohkouchi, Chiyo
Suzuki, Satoshi
Iwadate, Manabu
Midorikawa, Sanae
Yokoya, Susumu
Suzuki, Shinichi
Shimura, Hiroki
author_sort Ito, Yuko
collection PubMed
description BACKGROUND: Thyrotoxicosis is common disorder among endocrine dysfunctions. It is not rare that the free thyroid hormone level exceeds the measurement range of immunoassay. Such extreme high concentration of free thyroid hormone is generally considered to be impossible to measure correctly because of changes in the balance between free hormones and binding proteins by dilution of serum. Using liquid chromatography-tandem mass spectrometry (LC-MS/MS), however, higher concentrations are able to be determined. CASE PRESENTATION: We present a case of a 21-year-old female with congenital hypothyroidism who had taken a total of 5 mg levothyroxine over three consecutive days following discontinuance of the medication for a month. Immunoassay performed 3 hours after the last ingestion showed that the patient’s free thyroxine (FT4) was over 100 pmol/L and her free triiodothyronine (FT3) was 24.5 pmol/L. With a temporary cessation of levothyroxine, the patient was kept for observation without any other medication. Two days after the last ingestion, FT4 was still over 100 pmol/L and FT3 was increased to 28.8 pmol/L. After an additional 4 days, both FT4 and FT3 levels decreased. Through this period, no thyrotoxic symptom or physical sign had appeared. We also measured FT4 and FT3 levels in her cryopreserved serum by ultrafiltration LC-MS/MS. Her FT4 level measured by ultrafiltration LC-MS/MS on the visiting day and 2 days later were 160.0 and 135.5 pmol/L, respectively, indicating that the toxic dose of levothyroxine was partly changed to T3 during the 2 days. The FT3/FT4 ratios were revealed to be low, accounting for the patient’s benign clinical course despite temporal toxic exposure to levothyroxine. It is implied that prior discontinuation of supplementary levothyroxine increases potential vacant binding sites for thyroid hormone as a buffer to prevent toxic T3 effect. CONCLUSION: It was helpful to clarify the time dependent changes in free thyroid hormone levels by ultrafiltration LC-MS/MS in discussing the clinical course in this case. Though mass spectrometry has a disadvantage in speed for routine laboratory use, its accurate measurement, particularly of levels exceeding the measurable range of the immunoassay, provides valuable information for more appropriate management of extreme thyrotoxicosis.
format Online
Article
Text
id pubmed-7193347
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-71933472020-05-06 Time-dependent changes in FT4 and FT3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism Ito, Yuko Suzuki, Satoru Matsumoto, Yoshiko Ohkouchi, Chiyo Suzuki, Satoshi Iwadate, Manabu Midorikawa, Sanae Yokoya, Susumu Suzuki, Shinichi Shimura, Hiroki Thyroid Res Case Report BACKGROUND: Thyrotoxicosis is common disorder among endocrine dysfunctions. It is not rare that the free thyroid hormone level exceeds the measurement range of immunoassay. Such extreme high concentration of free thyroid hormone is generally considered to be impossible to measure correctly because of changes in the balance between free hormones and binding proteins by dilution of serum. Using liquid chromatography-tandem mass spectrometry (LC-MS/MS), however, higher concentrations are able to be determined. CASE PRESENTATION: We present a case of a 21-year-old female with congenital hypothyroidism who had taken a total of 5 mg levothyroxine over three consecutive days following discontinuance of the medication for a month. Immunoassay performed 3 hours after the last ingestion showed that the patient’s free thyroxine (FT4) was over 100 pmol/L and her free triiodothyronine (FT3) was 24.5 pmol/L. With a temporary cessation of levothyroxine, the patient was kept for observation without any other medication. Two days after the last ingestion, FT4 was still over 100 pmol/L and FT3 was increased to 28.8 pmol/L. After an additional 4 days, both FT4 and FT3 levels decreased. Through this period, no thyrotoxic symptom or physical sign had appeared. We also measured FT4 and FT3 levels in her cryopreserved serum by ultrafiltration LC-MS/MS. Her FT4 level measured by ultrafiltration LC-MS/MS on the visiting day and 2 days later were 160.0 and 135.5 pmol/L, respectively, indicating that the toxic dose of levothyroxine was partly changed to T3 during the 2 days. The FT3/FT4 ratios were revealed to be low, accounting for the patient’s benign clinical course despite temporal toxic exposure to levothyroxine. It is implied that prior discontinuation of supplementary levothyroxine increases potential vacant binding sites for thyroid hormone as a buffer to prevent toxic T3 effect. CONCLUSION: It was helpful to clarify the time dependent changes in free thyroid hormone levels by ultrafiltration LC-MS/MS in discussing the clinical course in this case. Though mass spectrometry has a disadvantage in speed for routine laboratory use, its accurate measurement, particularly of levels exceeding the measurable range of the immunoassay, provides valuable information for more appropriate management of extreme thyrotoxicosis. BioMed Central 2020-05-01 /pmc/articles/PMC7193347/ /pubmed/32377234 http://dx.doi.org/10.1186/s13044-020-00078-7 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Case Report
Ito, Yuko
Suzuki, Satoru
Matsumoto, Yoshiko
Ohkouchi, Chiyo
Suzuki, Satoshi
Iwadate, Manabu
Midorikawa, Sanae
Yokoya, Susumu
Suzuki, Shinichi
Shimura, Hiroki
Time-dependent changes in FT4 and FT3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism
title Time-dependent changes in FT4 and FT3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism
title_full Time-dependent changes in FT4 and FT3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism
title_fullStr Time-dependent changes in FT4 and FT3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism
title_full_unstemmed Time-dependent changes in FT4 and FT3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism
title_short Time-dependent changes in FT4 and FT3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism
title_sort time-dependent changes in ft4 and ft3 levels measured using mass spectrometry after an acute ingestion of excess levothyroxine in a case with hypothyroidism
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7193347/
https://www.ncbi.nlm.nih.gov/pubmed/32377234
http://dx.doi.org/10.1186/s13044-020-00078-7
work_keys_str_mv AT itoyuko timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT suzukisatoru timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT matsumotoyoshiko timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT ohkouchichiyo timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT suzukisatoshi timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT iwadatemanabu timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT midorikawasanae timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT yokoyasusumu timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT suzukishinichi timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism
AT shimurahiroki timedependentchangesinft4andft3levelsmeasuredusingmassspectrometryafteranacuteingestionofexcesslevothyroxineinacasewithhypothyroidism