Cargando…
Validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the Nor-Hand cohort
OBJECTIVE: Fluorescence optical imaging (FOI) demonstrates enhanced microcirculation in finger joints as a sign of inflammation. We wanted to assess the validity and diagnostic performance of FOI measuring synovitis in persons with hand OA, comparing it with magnetic resonance imaging (MRI)- and ult...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7193370/ https://www.ncbi.nlm.nih.gov/pubmed/32357904 http://dx.doi.org/10.1186/s13075-020-02185-0 |
_version_ | 1783528184586698752 |
---|---|
author | Maugesten, Øystein Mathiessen, Alexander Hammer, Hilde Berner Hestetun, Sigrid Valen Kvien, Tore Kristian Uhlig, Till Ohrndorf, Sarah Haugen, Ida Kristin |
author_facet | Maugesten, Øystein Mathiessen, Alexander Hammer, Hilde Berner Hestetun, Sigrid Valen Kvien, Tore Kristian Uhlig, Till Ohrndorf, Sarah Haugen, Ida Kristin |
author_sort | Maugesten, Øystein |
collection | PubMed |
description | OBJECTIVE: Fluorescence optical imaging (FOI) demonstrates enhanced microcirculation in finger joints as a sign of inflammation. We wanted to assess the validity and diagnostic performance of FOI measuring synovitis in persons with hand OA, comparing it with magnetic resonance imaging (MRI)- and ultrasound-detected synovitis. METHODS: Two hundred and twenty-one participants with hand OA underwent FOI and ultrasound (gray-scale synovitis and power Doppler activity) of the bilateral hands and contrast-enhanced MRI examination of the dominant hand. Fifteen joints in each hand were scored on semi-quantitative scales (grade 0–3) for all modalities. Four FOI images were evaluated: one composite image (Prima Vista Mode (PVM)) and three images representing phases of fluorescent dye distribution. Spearman’s correlation coefficients were calculated between sum scores of FOI, MRI, and ultrasound. Sensitivity, specificity, and area under the curve (AUC) were calculated for FOI using MRI or ultrasound as reference. RESULTS: FOI did not demonstrate enhancement in the thumb base, and the joint was excluded from further analyses. FOI sum scores showed poor to fair correlations with MRI (rho 0.01–0.24) and GS synovitis sum scores (rho 0.12–0.25). None of the FOI images demonstrated both good sensitivity and specificity, and the AUC ranged from 0.50–0.61 and 0.51–0.63 with MRI and GS synovitis as reference, respectively. FOI demonstrated similar diagnostic performance with PD activity and GS synovitis as reference. CONCLUSION: FOI enhancement correlated poorly with synovitis assessed by more established imaging modalities, questioning the value of FOI for the evaluation of synovitis in hand OA. |
format | Online Article Text |
id | pubmed-7193370 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-71933702020-05-06 Validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the Nor-Hand cohort Maugesten, Øystein Mathiessen, Alexander Hammer, Hilde Berner Hestetun, Sigrid Valen Kvien, Tore Kristian Uhlig, Till Ohrndorf, Sarah Haugen, Ida Kristin Arthritis Res Ther Research Article OBJECTIVE: Fluorescence optical imaging (FOI) demonstrates enhanced microcirculation in finger joints as a sign of inflammation. We wanted to assess the validity and diagnostic performance of FOI measuring synovitis in persons with hand OA, comparing it with magnetic resonance imaging (MRI)- and ultrasound-detected synovitis. METHODS: Two hundred and twenty-one participants with hand OA underwent FOI and ultrasound (gray-scale synovitis and power Doppler activity) of the bilateral hands and contrast-enhanced MRI examination of the dominant hand. Fifteen joints in each hand were scored on semi-quantitative scales (grade 0–3) for all modalities. Four FOI images were evaluated: one composite image (Prima Vista Mode (PVM)) and three images representing phases of fluorescent dye distribution. Spearman’s correlation coefficients were calculated between sum scores of FOI, MRI, and ultrasound. Sensitivity, specificity, and area under the curve (AUC) were calculated for FOI using MRI or ultrasound as reference. RESULTS: FOI did not demonstrate enhancement in the thumb base, and the joint was excluded from further analyses. FOI sum scores showed poor to fair correlations with MRI (rho 0.01–0.24) and GS synovitis sum scores (rho 0.12–0.25). None of the FOI images demonstrated both good sensitivity and specificity, and the AUC ranged from 0.50–0.61 and 0.51–0.63 with MRI and GS synovitis as reference, respectively. FOI demonstrated similar diagnostic performance with PD activity and GS synovitis as reference. CONCLUSION: FOI enhancement correlated poorly with synovitis assessed by more established imaging modalities, questioning the value of FOI for the evaluation of synovitis in hand OA. BioMed Central 2020-05-01 2020 /pmc/articles/PMC7193370/ /pubmed/32357904 http://dx.doi.org/10.1186/s13075-020-02185-0 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Maugesten, Øystein Mathiessen, Alexander Hammer, Hilde Berner Hestetun, Sigrid Valen Kvien, Tore Kristian Uhlig, Till Ohrndorf, Sarah Haugen, Ida Kristin Validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the Nor-Hand cohort |
title | Validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the Nor-Hand cohort |
title_full | Validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the Nor-Hand cohort |
title_fullStr | Validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the Nor-Hand cohort |
title_full_unstemmed | Validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the Nor-Hand cohort |
title_short | Validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the Nor-Hand cohort |
title_sort | validity and diagnostic performance of fluorescence optical imaging measuring synovitis in hand osteoarthritis: baseline results from the nor-hand cohort |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7193370/ https://www.ncbi.nlm.nih.gov/pubmed/32357904 http://dx.doi.org/10.1186/s13075-020-02185-0 |
work_keys_str_mv | AT maugestenøystein validityanddiagnosticperformanceoffluorescenceopticalimagingmeasuringsynovitisinhandosteoarthritisbaselineresultsfromthenorhandcohort AT mathiessenalexander validityanddiagnosticperformanceoffluorescenceopticalimagingmeasuringsynovitisinhandosteoarthritisbaselineresultsfromthenorhandcohort AT hammerhildeberner validityanddiagnosticperformanceoffluorescenceopticalimagingmeasuringsynovitisinhandosteoarthritisbaselineresultsfromthenorhandcohort AT hestetunsigridvalen validityanddiagnosticperformanceoffluorescenceopticalimagingmeasuringsynovitisinhandosteoarthritisbaselineresultsfromthenorhandcohort AT kvientorekristian validityanddiagnosticperformanceoffluorescenceopticalimagingmeasuringsynovitisinhandosteoarthritisbaselineresultsfromthenorhandcohort AT uhligtill validityanddiagnosticperformanceoffluorescenceopticalimagingmeasuringsynovitisinhandosteoarthritisbaselineresultsfromthenorhandcohort AT ohrndorfsarah validityanddiagnosticperformanceoffluorescenceopticalimagingmeasuringsynovitisinhandosteoarthritisbaselineresultsfromthenorhandcohort AT haugenidakristin validityanddiagnosticperformanceoffluorescenceopticalimagingmeasuringsynovitisinhandosteoarthritisbaselineresultsfromthenorhandcohort |