Cargando…
Fully automated rapid quantification of Hepatitis C Virus RNA in human plasma and serum by integrated on-chip RT-qPCR and capillary electrophoresis
The quantification of hepatitis C virus (HCV) is essential for the management of chronic hepatitis C therapy. We have developed a fully automated microfluidic RT-qPCR system for rapid quantitative detection of HCV RNA in human EDTA-plasma and serum, and the performance of the method was assessed. Th...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7193632/ https://www.ncbi.nlm.nih.gov/pubmed/32355190 http://dx.doi.org/10.1038/s41598-020-64169-z |
_version_ | 1783528231472726016 |
---|---|
author | Chan, Samuel D. H. Toyoda, Hidenori Sanjeeviraman, Jayashree Souppe, Aurelie Iwamoto, Mari Wu, Warren Eto, Daisuke Tada, Toshifumi Kumada, Takashi Zhang, Jian-Ping |
author_facet | Chan, Samuel D. H. Toyoda, Hidenori Sanjeeviraman, Jayashree Souppe, Aurelie Iwamoto, Mari Wu, Warren Eto, Daisuke Tada, Toshifumi Kumada, Takashi Zhang, Jian-Ping |
author_sort | Chan, Samuel D. H. |
collection | PubMed |
description | The quantification of hepatitis C virus (HCV) is essential for the management of chronic hepatitis C therapy. We have developed a fully automated microfluidic RT-qPCR system for rapid quantitative detection of HCV RNA in human EDTA-plasma and serum, and the performance of the method was assessed. The platform for the assay, µTASWako g1 Fully Automated Genetic Analyzer, performs automated sample preparation and RNA extraction, followed by amplification and detection on an integrated RT-qPCR-CE (capillary electrophoresis (CE)) microfluidic chip. The total assay time from sample input to data output is less than 120 minutes. The HCV assay has a linear quantitative range of 15 to 10(7) IU/mL, with a limit of detection (LOD) of 10.65 IU/mL in EDTA-plasma and 12.43 IU/mL in serum. The assay has a reproducibility of SD ≤ 0.16 log(10) IU/mL and an accuracy of ≤ 0.22 log(10) IU/mL difference when compared to the assigned values. The main HCV genotypes 1 to 6 are detected with an accuracy of ± 0.3 log(10) IU/mL. The assay is specific for HCV RNA and is free of interference from non-HCV pathogens, elevated levels of anti-viral and anti-bacterial drugs, and common endogenous interferents. In the linear quantitative range, the assay is highly correlated with the Roche cobas AmpliPrep/cobas TaqMan HCV Test, version 2.0 (r(2) = 0.949). As the assay is highly sensitive, accurate and specific, and provides reliable quantification of HCV in plasma and serum, it can potentially be applicable for monitoring the therapy and management of HCV infection. |
format | Online Article Text |
id | pubmed-7193632 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-71936322020-05-08 Fully automated rapid quantification of Hepatitis C Virus RNA in human plasma and serum by integrated on-chip RT-qPCR and capillary electrophoresis Chan, Samuel D. H. Toyoda, Hidenori Sanjeeviraman, Jayashree Souppe, Aurelie Iwamoto, Mari Wu, Warren Eto, Daisuke Tada, Toshifumi Kumada, Takashi Zhang, Jian-Ping Sci Rep Article The quantification of hepatitis C virus (HCV) is essential for the management of chronic hepatitis C therapy. We have developed a fully automated microfluidic RT-qPCR system for rapid quantitative detection of HCV RNA in human EDTA-plasma and serum, and the performance of the method was assessed. The platform for the assay, µTASWako g1 Fully Automated Genetic Analyzer, performs automated sample preparation and RNA extraction, followed by amplification and detection on an integrated RT-qPCR-CE (capillary electrophoresis (CE)) microfluidic chip. The total assay time from sample input to data output is less than 120 minutes. The HCV assay has a linear quantitative range of 15 to 10(7) IU/mL, with a limit of detection (LOD) of 10.65 IU/mL in EDTA-plasma and 12.43 IU/mL in serum. The assay has a reproducibility of SD ≤ 0.16 log(10) IU/mL and an accuracy of ≤ 0.22 log(10) IU/mL difference when compared to the assigned values. The main HCV genotypes 1 to 6 are detected with an accuracy of ± 0.3 log(10) IU/mL. The assay is specific for HCV RNA and is free of interference from non-HCV pathogens, elevated levels of anti-viral and anti-bacterial drugs, and common endogenous interferents. In the linear quantitative range, the assay is highly correlated with the Roche cobas AmpliPrep/cobas TaqMan HCV Test, version 2.0 (r(2) = 0.949). As the assay is highly sensitive, accurate and specific, and provides reliable quantification of HCV in plasma and serum, it can potentially be applicable for monitoring the therapy and management of HCV infection. Nature Publishing Group UK 2020-04-30 /pmc/articles/PMC7193632/ /pubmed/32355190 http://dx.doi.org/10.1038/s41598-020-64169-z Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Chan, Samuel D. H. Toyoda, Hidenori Sanjeeviraman, Jayashree Souppe, Aurelie Iwamoto, Mari Wu, Warren Eto, Daisuke Tada, Toshifumi Kumada, Takashi Zhang, Jian-Ping Fully automated rapid quantification of Hepatitis C Virus RNA in human plasma and serum by integrated on-chip RT-qPCR and capillary electrophoresis |
title | Fully automated rapid quantification of Hepatitis C Virus RNA in human plasma and serum by integrated on-chip RT-qPCR and capillary electrophoresis |
title_full | Fully automated rapid quantification of Hepatitis C Virus RNA in human plasma and serum by integrated on-chip RT-qPCR and capillary electrophoresis |
title_fullStr | Fully automated rapid quantification of Hepatitis C Virus RNA in human plasma and serum by integrated on-chip RT-qPCR and capillary electrophoresis |
title_full_unstemmed | Fully automated rapid quantification of Hepatitis C Virus RNA in human plasma and serum by integrated on-chip RT-qPCR and capillary electrophoresis |
title_short | Fully automated rapid quantification of Hepatitis C Virus RNA in human plasma and serum by integrated on-chip RT-qPCR and capillary electrophoresis |
title_sort | fully automated rapid quantification of hepatitis c virus rna in human plasma and serum by integrated on-chip rt-qpcr and capillary electrophoresis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7193632/ https://www.ncbi.nlm.nih.gov/pubmed/32355190 http://dx.doi.org/10.1038/s41598-020-64169-z |
work_keys_str_mv | AT chansamueldh fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT toyodahidenori fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT sanjeeviramanjayashree fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT souppeaurelie fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT iwamotomari fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT wuwarren fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT etodaisuke fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT tadatoshifumi fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT kumadatakashi fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis AT zhangjianping fullyautomatedrapidquantificationofhepatitiscvirusrnainhumanplasmaandserumbyintegratedonchiprtqpcrandcapillaryelectrophoresis |