Cargando…

Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year

BACKGROUND: The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar...

Descripción completa

Detalles Bibliográficos
Autores principales: Guarnieri, Renzo, Di Nardo, Dario, Di Giorgio, Gianni, Miccoli, Gabriele, Testarelli, Luca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7195691/
https://www.ncbi.nlm.nih.gov/pubmed/32382386
http://dx.doi.org/10.4317/jced.56277
_version_ 1783528589621198848
author Guarnieri, Renzo
Di Nardo, Dario
Di Giorgio, Gianni
Miccoli, Gabriele
Testarelli, Luca
author_facet Guarnieri, Renzo
Di Nardo, Dario
Di Giorgio, Gianni
Miccoli, Gabriele
Testarelli, Luca
author_sort Guarnieri, Renzo
collection PubMed
description BACKGROUND: The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar sockets, associated with a collagen membrane, after 3 years of loading. MATERIAL AND METHODS: Thirty patients underwent to placement of a non-submerged implants with a laser-microtextured collar into the inter radicular septum of mandibular molar fresh extraction sockets. A collagen membrane and the mucoperiosteal flap were adapted around the neck of the implants, leaving the laser-microtextured collar to heal in a transmucosal fashion. RESULTS: At the end of the follow-up period, no statistical differences were found for each radiographic measurements used for the examination of extraction sockets vertical bone changes. Compared to implants placement, at the end of the 3-year follow-up, the vertical radiographic mesial and distal peri-implant marginal bone levels showed a statistically significant gain of 0.9 (SD 0.5), and 1.0 mm (SD 0.6), respectively (P=0.037). CONCLUSIONS: In mandibular fresh extraction sockets, the method of GBR around transmucosal implants with laser-microtextured surface placed into the interadicular septum may be used successfully to counteract the ridge remodelling. Key words:Non-submerged implants, GBR, laser-microtextured collar.
format Online
Article
Text
id pubmed-7195691
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-71956912020-05-07 Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year Guarnieri, Renzo Di Nardo, Dario Di Giorgio, Gianni Miccoli, Gabriele Testarelli, Luca J Clin Exp Dent Research BACKGROUND: The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar sockets, associated with a collagen membrane, after 3 years of loading. MATERIAL AND METHODS: Thirty patients underwent to placement of a non-submerged implants with a laser-microtextured collar into the inter radicular septum of mandibular molar fresh extraction sockets. A collagen membrane and the mucoperiosteal flap were adapted around the neck of the implants, leaving the laser-microtextured collar to heal in a transmucosal fashion. RESULTS: At the end of the follow-up period, no statistical differences were found for each radiographic measurements used for the examination of extraction sockets vertical bone changes. Compared to implants placement, at the end of the 3-year follow-up, the vertical radiographic mesial and distal peri-implant marginal bone levels showed a statistically significant gain of 0.9 (SD 0.5), and 1.0 mm (SD 0.6), respectively (P=0.037). CONCLUSIONS: In mandibular fresh extraction sockets, the method of GBR around transmucosal implants with laser-microtextured surface placed into the interadicular septum may be used successfully to counteract the ridge remodelling. Key words:Non-submerged implants, GBR, laser-microtextured collar. Medicina Oral S.L. 2020-04-01 /pmc/articles/PMC7195691/ /pubmed/32382386 http://dx.doi.org/10.4317/jced.56277 Text en Copyright: © 2020 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Guarnieri, Renzo
Di Nardo, Dario
Di Giorgio, Gianni
Miccoli, Gabriele
Testarelli, Luca
Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year
title Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year
title_full Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year
title_fullStr Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year
title_full_unstemmed Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year
title_short Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year
title_sort immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to gbr: results at 3-year
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7195691/
https://www.ncbi.nlm.nih.gov/pubmed/32382386
http://dx.doi.org/10.4317/jced.56277
work_keys_str_mv AT guarnierirenzo immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year
AT dinardodario immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year
AT digiorgiogianni immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year
AT miccoligabriele immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year
AT testarelliluca immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year