Cargando…
Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year
BACKGROUND: The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7195691/ https://www.ncbi.nlm.nih.gov/pubmed/32382386 http://dx.doi.org/10.4317/jced.56277 |
_version_ | 1783528589621198848 |
---|---|
author | Guarnieri, Renzo Di Nardo, Dario Di Giorgio, Gianni Miccoli, Gabriele Testarelli, Luca |
author_facet | Guarnieri, Renzo Di Nardo, Dario Di Giorgio, Gianni Miccoli, Gabriele Testarelli, Luca |
author_sort | Guarnieri, Renzo |
collection | PubMed |
description | BACKGROUND: The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar sockets, associated with a collagen membrane, after 3 years of loading. MATERIAL AND METHODS: Thirty patients underwent to placement of a non-submerged implants with a laser-microtextured collar into the inter radicular septum of mandibular molar fresh extraction sockets. A collagen membrane and the mucoperiosteal flap were adapted around the neck of the implants, leaving the laser-microtextured collar to heal in a transmucosal fashion. RESULTS: At the end of the follow-up period, no statistical differences were found for each radiographic measurements used for the examination of extraction sockets vertical bone changes. Compared to implants placement, at the end of the 3-year follow-up, the vertical radiographic mesial and distal peri-implant marginal bone levels showed a statistically significant gain of 0.9 (SD 0.5), and 1.0 mm (SD 0.6), respectively (P=0.037). CONCLUSIONS: In mandibular fresh extraction sockets, the method of GBR around transmucosal implants with laser-microtextured surface placed into the interadicular septum may be used successfully to counteract the ridge remodelling. Key words:Non-submerged implants, GBR, laser-microtextured collar. |
format | Online Article Text |
id | pubmed-7195691 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-71956912020-05-07 Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year Guarnieri, Renzo Di Nardo, Dario Di Giorgio, Gianni Miccoli, Gabriele Testarelli, Luca J Clin Exp Dent Research BACKGROUND: The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar sockets, associated with a collagen membrane, after 3 years of loading. MATERIAL AND METHODS: Thirty patients underwent to placement of a non-submerged implants with a laser-microtextured collar into the inter radicular septum of mandibular molar fresh extraction sockets. A collagen membrane and the mucoperiosteal flap were adapted around the neck of the implants, leaving the laser-microtextured collar to heal in a transmucosal fashion. RESULTS: At the end of the follow-up period, no statistical differences were found for each radiographic measurements used for the examination of extraction sockets vertical bone changes. Compared to implants placement, at the end of the 3-year follow-up, the vertical radiographic mesial and distal peri-implant marginal bone levels showed a statistically significant gain of 0.9 (SD 0.5), and 1.0 mm (SD 0.6), respectively (P=0.037). CONCLUSIONS: In mandibular fresh extraction sockets, the method of GBR around transmucosal implants with laser-microtextured surface placed into the interadicular septum may be used successfully to counteract the ridge remodelling. Key words:Non-submerged implants, GBR, laser-microtextured collar. Medicina Oral S.L. 2020-04-01 /pmc/articles/PMC7195691/ /pubmed/32382386 http://dx.doi.org/10.4317/jced.56277 Text en Copyright: © 2020 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Guarnieri, Renzo Di Nardo, Dario Di Giorgio, Gianni Miccoli, Gabriele Testarelli, Luca Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year |
title | Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year |
title_full | Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year |
title_fullStr | Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year |
title_full_unstemmed | Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year |
title_short | Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year |
title_sort | immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to gbr: results at 3-year |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7195691/ https://www.ncbi.nlm.nih.gov/pubmed/32382386 http://dx.doi.org/10.4317/jced.56277 |
work_keys_str_mv | AT guarnierirenzo immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year AT dinardodario immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year AT digiorgiogianni immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year AT miccoligabriele immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year AT testarelliluca immediatenonsubmergedimplantswithlasermicrotexturedcollarplacedintheinterradicularseptumofmandibularmolarextractionsocketsassociatedtogbrresultsat3year |