Cargando…
Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons
The aim of this study was to determine (i) the reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons and (ii) the magnitude of hip flexion change with posterior pelvic tilt. Five experienced arthroscopic hip preservation surgeons (5–18 years of hip s...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7195937/ https://www.ncbi.nlm.nih.gov/pubmed/32382433 http://dx.doi.org/10.1093/jhps/hnz062 |
_version_ | 1783528629405220864 |
---|---|
author | Harris, Joshua D Mather, Richard C Nho, Shane J Salvo, John P Stubbs, Allston J Van Thiel, Geoffrey S Wolff, Andrew B Christoforetti, John J Ellis, Thomas J Matsuda, Dean K Kivlan, Benjamin R Carreira, Dominic S |
author_facet | Harris, Joshua D Mather, Richard C Nho, Shane J Salvo, John P Stubbs, Allston J Van Thiel, Geoffrey S Wolff, Andrew B Christoforetti, John J Ellis, Thomas J Matsuda, Dean K Kivlan, Benjamin R Carreira, Dominic S |
author_sort | Harris, Joshua D |
collection | PubMed |
description | The aim of this study was to determine (i) the reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons and (ii) the magnitude of hip flexion change with posterior pelvic tilt. Five experienced arthroscopic hip preservation surgeons (5–18 years of hip surgery experience) performed passive hip range of motion (internal and external rotation), flexion (contralateral hip extended) and flexion with posterior pelvic tilt (contralateral hip maximally flexed) on five young healthy asymptomatic volunteers (three males, two females; 34.4 ± 10.7 years of age). Motion was measured via digital photography and goniometry. Inter-observer reliability was calculated via two-way mixed, single measures, intra-class correlation coefficient. Paired t-test was utilized to compare hip flexion (with contralateral hip extended) to hip flexion with posterior pelvic tilt (with contralateral hip in forced flexion). The reliabilities of measurements of hip flexion with posterior pelvic tilt and external rotation were excellent, that of hip flexion was fair, and that of hip internal rotation was poor. The magnitude of hip flexion increase with posterior pelvic tilt was 17.0° ± 3.0° (P < 0.001). The reliability of hip range of motion measurement by five experienced arthroscopic hip preservation surgeons was excellent for measures of hip flexion with posterior pelvic tilt and external rotation. Contralateral maximal hip flexion significantly increased ipsilateral hip flexion (approximately 17°). Level of Evidence: Diagnostic, level III (without consistently applied reference standard) |
format | Online Article Text |
id | pubmed-7195937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-71959372020-05-07 Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons Harris, Joshua D Mather, Richard C Nho, Shane J Salvo, John P Stubbs, Allston J Van Thiel, Geoffrey S Wolff, Andrew B Christoforetti, John J Ellis, Thomas J Matsuda, Dean K Kivlan, Benjamin R Carreira, Dominic S J Hip Preserv Surg Research Articles The aim of this study was to determine (i) the reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons and (ii) the magnitude of hip flexion change with posterior pelvic tilt. Five experienced arthroscopic hip preservation surgeons (5–18 years of hip surgery experience) performed passive hip range of motion (internal and external rotation), flexion (contralateral hip extended) and flexion with posterior pelvic tilt (contralateral hip maximally flexed) on five young healthy asymptomatic volunteers (three males, two females; 34.4 ± 10.7 years of age). Motion was measured via digital photography and goniometry. Inter-observer reliability was calculated via two-way mixed, single measures, intra-class correlation coefficient. Paired t-test was utilized to compare hip flexion (with contralateral hip extended) to hip flexion with posterior pelvic tilt (with contralateral hip in forced flexion). The reliabilities of measurements of hip flexion with posterior pelvic tilt and external rotation were excellent, that of hip flexion was fair, and that of hip internal rotation was poor. The magnitude of hip flexion increase with posterior pelvic tilt was 17.0° ± 3.0° (P < 0.001). The reliability of hip range of motion measurement by five experienced arthroscopic hip preservation surgeons was excellent for measures of hip flexion with posterior pelvic tilt and external rotation. Contralateral maximal hip flexion significantly increased ipsilateral hip flexion (approximately 17°). Level of Evidence: Diagnostic, level III (without consistently applied reference standard) Oxford University Press 2019-12-12 /pmc/articles/PMC7195937/ /pubmed/32382433 http://dx.doi.org/10.1093/jhps/hnz062 Text en © The Author(s) 2020. Published by Oxford University Press. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Research Articles Harris, Joshua D Mather, Richard C Nho, Shane J Salvo, John P Stubbs, Allston J Van Thiel, Geoffrey S Wolff, Andrew B Christoforetti, John J Ellis, Thomas J Matsuda, Dean K Kivlan, Benjamin R Carreira, Dominic S Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons |
title | Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons |
title_full | Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons |
title_fullStr | Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons |
title_full_unstemmed | Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons |
title_short | Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons |
title_sort | reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7195937/ https://www.ncbi.nlm.nih.gov/pubmed/32382433 http://dx.doi.org/10.1093/jhps/hnz062 |
work_keys_str_mv | AT harrisjoshuad reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT matherrichardc reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT nhoshanej reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT salvojohnp reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT stubbsallstonj reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT vanthielgeoffreys reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT wolffandrewb reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT christoforettijohnj reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT ellisthomasj reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT matsudadeank reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT kivlanbenjaminr reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons AT carreiradominics reliabilityofhiprangeofmotionmeasurementamongexperiencedarthroscopichippreservationsurgeons |