Cargando…

Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes

Background: This study undertook to assess usability, 24-h glycemic profiles, and safety of an investigational basal/bolus insulin delivery device (IDD) providing rapid-acting or regular human insulin (RHI) for people with type 2 diabetes (T2D) transitioning from multiple daily insulin injections (M...

Descripción completa

Detalles Bibliográficos
Autores principales: Aronson, Ronnie, Mahoney, Edward, Saliu, Drilon, Sze, David, Morel, Didier, Bergquist, Leya, Hirsch, Laurence
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mary Ann Liebert, Inc., publishers 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7196361/
https://www.ncbi.nlm.nih.gov/pubmed/31692373
http://dx.doi.org/10.1089/dia.2019.0356
_version_ 1783528709499650048
author Aronson, Ronnie
Mahoney, Edward
Saliu, Drilon
Sze, David
Morel, Didier
Bergquist, Leya
Hirsch, Laurence
author_facet Aronson, Ronnie
Mahoney, Edward
Saliu, Drilon
Sze, David
Morel, Didier
Bergquist, Leya
Hirsch, Laurence
author_sort Aronson, Ronnie
collection PubMed
description Background: This study undertook to assess usability, 24-h glycemic profiles, and safety of an investigational basal/bolus insulin delivery device (IDD) providing rapid-acting or regular human insulin (RHI) for people with type 2 diabetes (T2D) transitioning from multiple daily insulin injections (MDIs). Methods: This prospective, single-center, open-label two-period study enrolled adults with T2D and glycated hemoglobin (HbA1c) 7%–11% (53–97 mmol/M). Participants continued the usual MDI therapy during a 2- to 3-day in-clinic MDI period and then within 7 days were switched to the IDD, using current insulin dose, for a 6-day in-clinic IDD period, with blinded continuous glucose monitoring throughout the in-clinic periods. Results: We enrolled 21 participants (mean ± standard deviation age 57 ± 8 years; HbA1c 8.2% ± 0.9% [66 ± 9.8 mmol/M]) using U-100 insulin lispro (n = 11) or who switched to U-100 RHI (n = 10). Glycemic measures improved from the MDI to IDD period, including fasting blood glucose (BG), 141.2 ± 38.3 mg/dL (7.8 ± 2.1 mmol/L) versus 121.2 ± 35.0 mg/dL (6.7 ± 1.9 mmol/L; P = 0.002), respectively; 24-h mean BG, 137.0 ± 20.5 mg/dL (7.6 ± 1.1 mmol/L) versus 125.0 ± 16.5 mg/dL (6.9 ± 0.9 mmol/L; P = 0.004); and time in range (at 70–180 mg/dL; 3.9–10 mmol/L), 81.0% ± 14.4% versus 87.5% ± 10.6% (P = 0.008). No significant differences between MDIs and IDD use were recorded for time <70 mg/dL (1.6% ± 2.7% vs. 3.1% ± 2.7%, P = 0.08), CV%, or mean of daily differences. Mean amplitude of glycemic excursions was significantly lower with the IDD (P = 0.011). There were no significant differences between insulin lispro and RHI for any glycemic measure. No serious adverse events were recorded. Conclusions: In the context of this exploratory study, the IDD was safe and effective to administer insulin lispro and RHI for adults with T2D.
format Online
Article
Text
id pubmed-7196361
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Mary Ann Liebert, Inc., publishers
record_format MEDLINE/PubMed
spelling pubmed-71963612020-05-04 Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes Aronson, Ronnie Mahoney, Edward Saliu, Drilon Sze, David Morel, Didier Bergquist, Leya Hirsch, Laurence Diabetes Technol Ther Original Articles Background: This study undertook to assess usability, 24-h glycemic profiles, and safety of an investigational basal/bolus insulin delivery device (IDD) providing rapid-acting or regular human insulin (RHI) for people with type 2 diabetes (T2D) transitioning from multiple daily insulin injections (MDIs). Methods: This prospective, single-center, open-label two-period study enrolled adults with T2D and glycated hemoglobin (HbA1c) 7%–11% (53–97 mmol/M). Participants continued the usual MDI therapy during a 2- to 3-day in-clinic MDI period and then within 7 days were switched to the IDD, using current insulin dose, for a 6-day in-clinic IDD period, with blinded continuous glucose monitoring throughout the in-clinic periods. Results: We enrolled 21 participants (mean ± standard deviation age 57 ± 8 years; HbA1c 8.2% ± 0.9% [66 ± 9.8 mmol/M]) using U-100 insulin lispro (n = 11) or who switched to U-100 RHI (n = 10). Glycemic measures improved from the MDI to IDD period, including fasting blood glucose (BG), 141.2 ± 38.3 mg/dL (7.8 ± 2.1 mmol/L) versus 121.2 ± 35.0 mg/dL (6.7 ± 1.9 mmol/L; P = 0.002), respectively; 24-h mean BG, 137.0 ± 20.5 mg/dL (7.6 ± 1.1 mmol/L) versus 125.0 ± 16.5 mg/dL (6.9 ± 0.9 mmol/L; P = 0.004); and time in range (at 70–180 mg/dL; 3.9–10 mmol/L), 81.0% ± 14.4% versus 87.5% ± 10.6% (P = 0.008). No significant differences between MDIs and IDD use were recorded for time <70 mg/dL (1.6% ± 2.7% vs. 3.1% ± 2.7%, P = 0.08), CV%, or mean of daily differences. Mean amplitude of glycemic excursions was significantly lower with the IDD (P = 0.011). There were no significant differences between insulin lispro and RHI for any glycemic measure. No serious adverse events were recorded. Conclusions: In the context of this exploratory study, the IDD was safe and effective to administer insulin lispro and RHI for adults with T2D. Mary Ann Liebert, Inc., publishers 2020-05-01 2020-04-27 /pmc/articles/PMC7196361/ /pubmed/31692373 http://dx.doi.org/10.1089/dia.2019.0356 Text en © Ronnie Aronson, et al., 2019; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.
spellingShingle Original Articles
Aronson, Ronnie
Mahoney, Edward
Saliu, Drilon
Sze, David
Morel, Didier
Bergquist, Leya
Hirsch, Laurence
Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes
title Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes
title_full Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes
title_fullStr Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes
title_full_unstemmed Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes
title_short Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes
title_sort safety and effectiveness of an investigational insulin delivery device providing basal/bolus therapy with rapid-acting or regular human insulin in adults with type 2 diabetes
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7196361/
https://www.ncbi.nlm.nih.gov/pubmed/31692373
http://dx.doi.org/10.1089/dia.2019.0356
work_keys_str_mv AT aronsonronnie safetyandeffectivenessofaninvestigationalinsulindeliverydeviceprovidingbasalbolustherapywithrapidactingorregularhumaninsulininadultswithtype2diabetes
AT mahoneyedward safetyandeffectivenessofaninvestigationalinsulindeliverydeviceprovidingbasalbolustherapywithrapidactingorregularhumaninsulininadultswithtype2diabetes
AT saliudrilon safetyandeffectivenessofaninvestigationalinsulindeliverydeviceprovidingbasalbolustherapywithrapidactingorregularhumaninsulininadultswithtype2diabetes
AT szedavid safetyandeffectivenessofaninvestigationalinsulindeliverydeviceprovidingbasalbolustherapywithrapidactingorregularhumaninsulininadultswithtype2diabetes
AT moreldidier safetyandeffectivenessofaninvestigationalinsulindeliverydeviceprovidingbasalbolustherapywithrapidactingorregularhumaninsulininadultswithtype2diabetes
AT bergquistleya safetyandeffectivenessofaninvestigationalinsulindeliverydeviceprovidingbasalbolustherapywithrapidactingorregularhumaninsulininadultswithtype2diabetes
AT hirschlaurence safetyandeffectivenessofaninvestigationalinsulindeliverydeviceprovidingbasalbolustherapywithrapidactingorregularhumaninsulininadultswithtype2diabetes