PURPOSE: To report a novel technique of cross-knotted suture basket and to test its effectiveness in large nonmagnetic intraocular foreign body (IOFB) removal. METHODS: A 7/0 Vicryl suture was cut in half and cross-knotted, and four ends were introduced into a 23G needle to form a basket. Pig eyes w...

Descripción completa

Detalles Bibliográficos
Autores principales: Cao, Jian, Chen, Baihua, Li, Yun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7196965/
https://www.ncbi.nlm.nih.gov/pubmed/32377410
http://dx.doi.org/10.1155/2020/1061462
_version_ 1783528796798844928
author Cao, Jian
Chen, Baihua
Li, Yun
author_facet Cao, Jian
Chen, Baihua
Li, Yun
author_sort Cao, Jian
collection PubMed
description PURPOSE: To report a novel technique of cross-knotted suture basket and to test its effectiveness in large nonmagnetic intraocular foreign body (IOFB) removal. METHODS: A 7/0 Vicryl suture was cut in half and cross-knotted, and four ends were introduced into a 23G needle to form a basket. Pig eyes were used to set up the IOFB model, and the effectiveness of the suture basket in the removal of large nonmagnetic intraocular foreign bodies was tested. RESULTS: Several modifications can be made to adapt to different situations. For the materials (stone, metal, glass, and wood) and shapes (irregular, spherical, and rectangle) of large IOFB tested, the cross-knotted suture basket successfully removed all kinds of IOFBs. CONCLUSION: The suture basket technique provides an accessible, safe, and effective alternative in large nonmagnetic IOFB removal. It can be adapted and interchangedand also worth's further clinical investigations.
format Online
Article
Text
id pubmed-7196965
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-71969652020-05-06 A Cross-Knotted Suture Basket Technique for Large Nonmagnetic Intraocular Foreign Body Removal Cao, Jian Chen, Baihua Li, Yun J Ophthalmol Research Article PURPOSE: To report a novel technique of cross-knotted suture basket and to test its effectiveness in large nonmagnetic intraocular foreign body (IOFB) removal. METHODS: A 7/0 Vicryl suture was cut in half and cross-knotted, and four ends were introduced into a 23G needle to form a basket. Pig eyes were used to set up the IOFB model, and the effectiveness of the suture basket in the removal of large nonmagnetic intraocular foreign bodies was tested. RESULTS: Several modifications can be made to adapt to different situations. For the materials (stone, metal, glass, and wood) and shapes (irregular, spherical, and rectangle) of large IOFB tested, the cross-knotted suture basket successfully removed all kinds of IOFBs. CONCLUSION: The suture basket technique provides an accessible, safe, and effective alternative in large nonmagnetic IOFB removal. It can be adapted and interchangedand also worth's further clinical investigations. Hindawi 2020-04-25 /pmc/articles/PMC7196965/ /pubmed/32377410 http://dx.doi.org/10.1155/2020/1061462 Text en Copyright © 2020 Jian Cao et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Cao, Jian
Chen, Baihua
Li, Yun
A Cross-Knotted Suture Basket Technique for Large Nonmagnetic Intraocular Foreign Body Removal
title A Cross-Knotted Suture Basket Technique for Large Nonmagnetic Intraocular Foreign Body Removal
title_full A Cross-Knotted Suture Basket Technique for Large Nonmagnetic Intraocular Foreign Body Removal
title_fullStr A Cross-Knotted Suture Basket Technique for Large Nonmagnetic Intraocular Foreign Body Removal
title_full_unstemmed A Cross-Knotted Suture Basket Technique for Large Nonmagnetic Intraocular Foreign Body Removal
title_short A Cross-Knotted Suture Basket Technique for Large Nonmagnetic Intraocular Foreign Body Removal
title_sort cross-knotted suture basket technique for large nonmagnetic intraocular foreign body removal
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7196965/
https://www.ncbi.nlm.nih.gov/pubmed/32377410
http://dx.doi.org/10.1155/2020/1061462
work_keys_str_mv AT caojian acrossknottedsuturebaskettechniqueforlargenonmagneticintraocularforeignbodyremoval
AT chenbaihua acrossknottedsuturebaskettechniqueforlargenonmagneticintraocularforeignbodyremoval
AT liyun acrossknottedsuturebaskettechniqueforlargenonmagneticintraocularforeignbodyremoval
AT caojian crossknottedsuturebaskettechniqueforlargenonmagneticintraocularforeignbodyremoval
AT chenbaihua crossknottedsuturebaskettechniqueforlargenonmagneticintraocularforeignbodyremoval
AT liyun crossknottedsuturebaskettechniqueforlargenonmagneticintraocularforeignbodyremoval