Biomechanical study of space frame structure based on bone cement screw

Stability of space frame structures with bone cement screw reinforcement by biomechanical testing was analyzed. Seven complete human spine specimens with osteoporosis were selected. Three specimens were separated into 18 vertebral bodies. Nine vertebral bodies were randomly selected and bone cement...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiu, Jintao, Bu, Tao, Yan, Yabo, Wu, Zixiang, Yin, Zhanhai, Lei, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7197252/
https://www.ncbi.nlm.nih.gov/pubmed/32373193
http://dx.doi.org/10.3892/etm.2020.8659
_version_ 1783528840726839296
author Xiu, Jintao
Bu, Tao
Yan, Yabo
Wu, Zixiang
Yin, Zhanhai
Lei, Wei
author_facet Xiu, Jintao
Bu, Tao
Yan, Yabo
Wu, Zixiang
Yin, Zhanhai
Lei, Wei
author_sort Xiu, Jintao
collection PubMed
description Stability of space frame structures with bone cement screw reinforcement by biomechanical testing was analyzed. Seven complete human spine specimens with osteoporosis were selected. Three specimens were separated into 18 vertebral bodies. Nine vertebral bodies were randomly selected and bone cement screws were implanted on both sides. Bone cement was used to form a bridge at the front end of the two screws (single vertebral group A). The other nine vertebral bodies were implanted with cement screws on both sides, but the front ends of the two screws were not bridged (single vertebral group B). The remaining spine specimens were used for biomechanical testing of the overall stability of the three-dimensional frame. The four specimens were osteotomized, and then two specimens were randomly selected. Bone cement screws were implanted on both sides of the vertebral body, and a bone cement bridge was formed at the front end of the two screws to establish a three-dimensional frame structure (multi-vertebral group A). The other two spine specimens were implanted with cement screws on both sides of the vertebral body, but the front ends of the two screws were not bridged (multi-vertebral group B). A statistical difference was found between the extractive force of bridged and non-bridged specimens. Group B showed some loosening of screws after the test. The stability of the triangle structure screw, which was formed after the bridge was established at the front end of the single-vertebral bone cement screw, was significantly enhanced. Moreover, the stability was significantly improved after the three-dimensional frame structure was established in the multi-vertebral body group, providing a new method for clinical improvement of the stability and reliability of internal fixation in patients with severe osteoporosis and spinal disease.
format Online
Article
Text
id pubmed-7197252
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-71972522020-05-05 Biomechanical study of space frame structure based on bone cement screw Xiu, Jintao Bu, Tao Yan, Yabo Wu, Zixiang Yin, Zhanhai Lei, Wei Exp Ther Med Articles Stability of space frame structures with bone cement screw reinforcement by biomechanical testing was analyzed. Seven complete human spine specimens with osteoporosis were selected. Three specimens were separated into 18 vertebral bodies. Nine vertebral bodies were randomly selected and bone cement screws were implanted on both sides. Bone cement was used to form a bridge at the front end of the two screws (single vertebral group A). The other nine vertebral bodies were implanted with cement screws on both sides, but the front ends of the two screws were not bridged (single vertebral group B). The remaining spine specimens were used for biomechanical testing of the overall stability of the three-dimensional frame. The four specimens were osteotomized, and then two specimens were randomly selected. Bone cement screws were implanted on both sides of the vertebral body, and a bone cement bridge was formed at the front end of the two screws to establish a three-dimensional frame structure (multi-vertebral group A). The other two spine specimens were implanted with cement screws on both sides of the vertebral body, but the front ends of the two screws were not bridged (multi-vertebral group B). A statistical difference was found between the extractive force of bridged and non-bridged specimens. Group B showed some loosening of screws after the test. The stability of the triangle structure screw, which was formed after the bridge was established at the front end of the single-vertebral bone cement screw, was significantly enhanced. Moreover, the stability was significantly improved after the three-dimensional frame structure was established in the multi-vertebral body group, providing a new method for clinical improvement of the stability and reliability of internal fixation in patients with severe osteoporosis and spinal disease. D.A. Spandidos 2020-06 2020-04-09 /pmc/articles/PMC7197252/ /pubmed/32373193 http://dx.doi.org/10.3892/etm.2020.8659 Text en Copyright: © Xiu et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Xiu, Jintao
Bu, Tao
Yan, Yabo
Wu, Zixiang
Yin, Zhanhai
Lei, Wei
Biomechanical study of space frame structure based on bone cement screw
title Biomechanical study of space frame structure based on bone cement screw
title_full Biomechanical study of space frame structure based on bone cement screw
title_fullStr Biomechanical study of space frame structure based on bone cement screw
title_full_unstemmed Biomechanical study of space frame structure based on bone cement screw
title_short Biomechanical study of space frame structure based on bone cement screw
title_sort biomechanical study of space frame structure based on bone cement screw
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7197252/
https://www.ncbi.nlm.nih.gov/pubmed/32373193
http://dx.doi.org/10.3892/etm.2020.8659
work_keys_str_mv AT xiujintao biomechanicalstudyofspaceframestructurebasedonbonecementscrew
AT butao biomechanicalstudyofspaceframestructurebasedonbonecementscrew
AT yanyabo biomechanicalstudyofspaceframestructurebasedonbonecementscrew
AT wuzixiang biomechanicalstudyofspaceframestructurebasedonbonecementscrew
AT yinzhanhai biomechanicalstudyofspaceframestructurebasedonbonecementscrew
AT leiwei biomechanicalstudyofspaceframestructurebasedonbonecementscrew